The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: A multicenter study
Abstract
Objective To evaluate an implanted neuroprosthesis that allows tetraplegic users to control grasp and release in 1 hand.Design Multicenter cohort trial with at least 3 years of follow-up. Function for each participant was compared before and after implantation, and with and without the neuroprosthesis activated.Setting Tertiary spinal cord injury (SCI) care centers, 8 in the United States, 1 in the United Kingdom, and 1 in Australia.Participants Fifty-one tetraplegic adults with C5 or C6 SCIs.Intervention An implanted neuroprosthetic system, in which electric stimulation of the grasping muscles of 1 arm are controlled by using contralateral shoulder movements, and concurrent tendon transfer surgery. Assessed participants' ability to grasp, move, and release standardized objects; degree of assistance required to perform activities of daily living (ADLs), device usage; and user satisfaction.Main outcome measures Pinch force; grasp and release tests; ADL abilities test and ADL assessment test; and user satisfaction survey.Results Pinch force was significantly greater with the neuroprosthesis in all available 50 participants, and grasp-release abilities were improved in 49. All tested participants (49/49) were more independent in performing ADLs with the neuroprosthesis than they were without it. Home use of the device for regular function and exercise was reported by over 90% of the participants, and satisfaction with the neuroprosthesis was high.Conclusions The grasping ability provided by the neuroprosthesis is substantial and lasting. The neuroprosthesis is safe, well accepted by users, and offers improved independence for a population without comparable alternatives.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It has been found suitable and reliable in both upper and lower extremity applications in various clinical studies [27, 28].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [27]
Citations
Cites
Statistical Power Analysis for the Behavioral Sciences
Muller, K. E., & Cohen, J. (1989) · Technometrics · doi:10.2307/1270020 · Cited by 99,603
Statistical power analysis for the behavioral sciences
Cohen, J. (1990) · Computers Environment and Urban Systems · doi:10.1016/0198-9715(90)90050-4 · Cited by 65,417
Spinal Cord Injury: Clinical Outcomes from the Model Systems
Stover, S. L., DeLisa, J. A., & Whiteneck, G. G. (1995) · Medical Entomology and Zoology · Cited by 401
Spinal Cord Injury: Clinical Outcomes from the Model Systems
Parent, N. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00008 · Cited by 387
Smith, B., Peckham, P. H., Keith, M. W., & Roscoe, D. D. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325979 · Cited by 281
Self-citationImplantable functional neuromuscular stimulation in the tetraplegic hand
Keith, M. W., Peckham, P. H., Thrope, G. B., Stroh, K. C., Smith, B., Buckett, J. R., Kilgore, K. L., & Jatich, J. W. (1989) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(89)80017-6 · Cited by 212
Self-citationWuolle, K. S., Doren, C. L. V., Thrope, G. B., Keith, M. W., & Peckham, P. H. (1994) · The Journal Of Hand Surgery · doi:10.1016/0363-5023(94)90008-6 · Cited by 198
Self-citationMcDowell, C. L., Moberg, E., & House, J. H. (1986) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(86)80213-1 · Cited by 198
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citationMoberg, E., McDowell, C. L., & House, J. H. (1989) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(89)80064-4 · Cited by 178
Flagged first, then by citations
Research works printed but not linked: 1
- Betz, 1994, Bipolar latissimus dorsi transposition and functional nerve stimulation in adolescents with C5 tetraplegia, Arch Phys Med Rehabil, 75, 939
Cited by
Sorted by citations
Items 101–200 of 317
Evaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys
Brill, N., Naufel, S. N., Polasek, K. H., Éthier, C., Cheesborough, J. E., Agnew, S. P., Miller, L. E., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8735 · Cited by 30
Two-dimensional materials for wireless power transfer
Gao, M., Yao, Y., Yang, F., Ye, J., Liu, G., Wang, B., Liu, S., Wang, P., & Lu, Y. (2023) · Device · doi:10.1016/j.device.2023.100022 · Cited by 32
Prediction of muscle activity during loaded movements of the upper limb
Tibold, R., & Fuglevand, A. J. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-6 · Cited by 29
“individuals [1-16].”
Overcoming Abnormal Joint Torque Patterns in Paretic Upper Extremities Using Triceps Stimulation
Keller, T., Ellis, M. D., & Dewald, J. P. A. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29041.x · Cited by 29
“(3) Absence of severe wasting or contracture of the impaired upper limb; (4) Absence of significant sensory deficits in the impaired upper limb; (5) Absence of severe cognitive or affective dysfunction; (6) Absence of severe concurrent medical problems; and (7) Absence of brainstem lesions as determined from clinical…”
BackgroundMuller-Putz, G. R., Rupp, R., Ofner, P., Pereira, J., Pinegger, A., Schwarz, A., Zube, M., Eck, U., Hessing, B., & Schneiders, M. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856491 · Cited by 28
“Although there are some end users studies with home use of BCIs [17] or of grasp neuroprostheses [18], this study combines technologies from different fields resulting in high training and interaction efforts of the experts involved.”
BackgroundBrain Computer Interface for Hand Motor Function Restoration and Rehabilitation
Mattia, D., Pichiorri, F., Molinari, M., & Rupp, R. (2012) · Biological and medical physics series · doi:10.1007/978-3-642-29746-5_7 · Cited by 28
International Spinal Cord Injury Upper Extremity Basic Data Set
Biering‐Sørensen, F., Bryden, A. M., Curt, A. E. P., Fridén, J. O., Harvey, L. A., Mulcahey, M. J., Popović, M. R., Procházka, A., Sinnott, K. A., & Snoek, G. J. (2014) · Spinal Cord · doi:10.1038/sc.2014.87 · Cited by 27
Self-citationMimicking muscle activity with electrical stimulation
Johnson, L. A., & Fuglevand, A. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016009 · Cited by 27
Upper limb sensorimotor restoration through brain–computer interface technology in tetraparesis
Bockbrader, M. A. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.09.002 · Cited by 29
Snoek, G. J., van Til, J. A., Krabbe, P. F. M., & IJzerman, M. J. (2007) · Spinal Cord · doi:10.1038/sj.sc.3102110 · Cited by 26
“A CA comprises of 5 stages, including (1) identification of typical elements, also called attributes, of the therapy which is investigated; (2) assignment of various levels to the attributes; (3) design of a series of hypothetical”
BackgroundChapter 9 Flexibility and Practicality
Scherer, R., Muller-Putz, G. R., & Pfurtscheller, G. (2009) · International review of neurobiology · doi:10.1016/s0074-7742(09)86009-1 · Cited by 26
Thomas, P. S., Branicky, M. S., van den Bogert, A. J., & Jagodnik, K. M. (2009) · PubMed · Cited by 25
Gant, K. L., Guerra, S., Zimmerman, L., Parks, B. A., Prins, N. W., & Prasad, A. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aabb13 · Cited by 26
Patient preferences for reconstructive interventions of the upper limb in tetraplegia
Snoek, G. J. (2005) · University of Twente Research Information · Cited by 25
Indications and future directions for upper limb neuroprostheses in tetraplegic patients: a review
Keith, M. W., & Hoyen, H. A. (2002) · Hand Clinics · doi:10.1016/s0749-0712(02)00034-3 · Cited by 24
Self-citationImplanted Neuroprostheses for Restoration of Hand Function in Tetraplegic Patients
Cornwall, R., & Hausman, M. R. (2004) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200403000-00002 · Cited by 24
Rupp, R., & Gerner, H. J. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.019 · Cited by 31
Signal acquisition and analysis for cortical control of neuroprosthetics
Tillery, S. I. H., & Taylor, D. M. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.013 · Cited by 22
“For people with high-level spinal cord injuries, restoration of arm and hand function is now possible through the use of implanted functional electrical stimulation (FES) systems that activate paralyzed muscles through controlled stimulation of the peripheral nerves [3,4].”
BackgroundAdaptive Neuro-Fuzzy Sliding Mode Control of Multi-Joint Movement Using Intraspinal Microstimulation
Asadi, A., & Erfanian, A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2197828 · Cited by 23
Evaluation of probabilistic methods to predict muscle activity: implications for neuroprosthetics
Johnson, L. A., & Fuglevand, A. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055008 · Cited by 23
“…have been overcome (Ko et al 1977, Keith et al 1988, Handa et al 1989, Hoshimiya et al 1989, Kilgore et al 1989, Peckham et al 2002) and a growing number of patients are using FES systems to regain some of the function of their upper limbs (Triolo et al 1996, Smith et al 1987, Peckham et al 2001).”
BackgroundRestorative Treatments for Spinal Cord Injury
Chen, S., & Levi, A. D. (2016) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2016.08.004 · Cited by 23
Kilgore, K. L., Bryden, A. M., Keith, M. W., Hoyen, H. A., Hart, R. L., Nemunaitis, G. A., & Peckham, P. H. (2018) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2403-252 · Cited by 23
“These results match the results obtained with the earlier generation of neuroprosthesis, where 100% of that cohort also achieved increased grip strength.(11) The high success rate is due, in large part, to the fact that subject screening using surface stimulation(25) is a good predictor of functional movements.”
MethodResultInfluentialSelf-citationUpper limb functional electrical stimulation devices and their man–machine interfaces
Venugopalan, L., Taylor, P. N., Cobb, J. E., & Swain, I. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1102344 · Cited by 22
“Fifty volunteers with C5 or C6 tetraplegia participated in a multi-centre trial to clinically evaluate this device [3].”
BackgroundMethodKalsi‐Ryan, S., & Verrier, M. C. (2011) · Physiotherapy Canada · doi:10.3138/ptc.2009-46 · Cited by 22
Satisfaction with upper extremity surgery in individuals with tetraplegia
Gregersen, H., Lybæk, M., Johannesen, I. L., Leicht, P., Nissen, U. V., & Biering‐Sørensen, F. (2014) · Journal of Spinal Cord Medicine · doi:10.1179/2045772314y.0000000259 · Cited by 22
Wireless wearable controller for upper-limb neuroprosthesis.
Wheeler, C. A., & Peckham, P. H. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.03.0037 · Cited by 22
Self-citationTrincado-Alonso, F., López-Larraz, E., Resquín, F., Ardanza, A., Pérez-Nombela, S., Pons, J., Montesano, L., & Gil-Agudo, Á. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-017-0343-0 · Cited by 1
Twenty year experience with implanted neuroprostheses
Kilgore, K. L., Peckham, P. H., & Keith, M. W. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335272 · Cited by 22
“A multi-center clinical trial was conducted with the Freehand System from 1992-1997 [ 3 ].”
BackgroundMethodInfluentialSelf-citationCoste, C., William, L., da Fonseca, L. O., Hiairrassary, A., Andreu, D., Geffrier, A., Teissier, J., Fattal, C., & Guiraud, D. (2022) · Scientific Reports · doi:10.1038/s41598-022-19906-x · Cited by 26
“The only widely used successful device that has been proposed was the FreeHand®: more than 250 patients 23 have had it successfully implanted with clear benefits, proving the interest of such a technological solution for recovering hand movements 24 .”
MethodGait Restoration by Functional Electrical Stimulation
Durfee, W. K. (2006) · Springer eBooks · doi:10.1007/3-540-26415-9_2 · Cited by 21
“be activated to restore rudimentary grasp [3, 4] while for paraplegics, leg”
An Implanted Neuroprosthesis for High Tetraplegia
Bryden, A. M., Kilgore, K. L., Kirsch, R. F., Memberg, W. D., Peckham, P. H., & Keith, M. W. (2005) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/g9t5-cck9-y0wt-4714 · Cited by 21
Self-citationFairchild, M. D., Kim, S.-J., Iarkov, A., Abbas, J. J., & Jung, R. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2010.02.011 · Cited by 20
“…as a neuroprosthesis for replacing lost coordinated motor function in people with complete SCI, for example for grasping (Mangold, et al., 2005, Peckham, et al., 2001), standing and posture (Abbas and Gillette, 2001), or rhythmic leg movement (Riess and Abbas, 2000, Riess and Abbas, 2001,…”
Évolution de la prise en charge chirurgicale du membre supérieur tétraplégique depuis 50 ans
Fattal, C., Teissier, J., Leclercq, C., Revol, M. P., & Enjalbert, M. (2003) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/s0168-6054(03)00014-x · Cited by 20
Charkhkar, H., Christie, B. P., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108414 · Cited by 19
Decoding neural activity to predict rat locomotion using intracortical and epidural arrays
Barroso, F. O., Yoder, B., Tentler, D. P., Wallner, J. J., Kinkhabwala, A. A., Jantz, M., Flint, R. D., Tostado-Marcos, P., Pei, E., Satish, A. D. R., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0698 · Cited by 21
Cole, N. M., & Ajiboye, A. B. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2d47 · Cited by 19
“With one input for switching between grasp states and another input for modulating the hand aperture, users could produce 2–4 reliable hand grasp motions, thereby regaining sufficient hand function to successfully perform a limited but impactful number of activities of daily living [4].”
BackgroundFattal, C., & Leblond, C. (2005) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/j.annrmp.2005.03.006 · Cited by 18
“[76] Peckham PH, Keith MW, Kilgore KL, Grill JH, Wuolle KS, Thrope GB, et al.”
BackgroundMethodKilgore, K. L., Hart, R. L., Montague, F. W., Bryden, A. M., Keith, M. W., Hoyen, H. A., Sams, C. J., & Peckham, P. H. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259939 · Cited by 18
“The IST-12 system provides some significant improvements over the first generation Freehand system [5, 13 ].”
MethodSelf-citationSharma, P., Panta, T., Ugiliweneza, B., Bert, R. J., Gerasimenko, Y., Forrest, G. F., & Harkema, S. J. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12134416 · Cited by 20
“Therefore, even a small functional gain in the upper extremity function can greatly enhance their quality of life and independence [4].”
BackgroundRecapitulating Flesh with Silicon and Steel: Advancements in Upper Extremity Robotic Prosthetics
Lee, B., Attenello, F. J., Liu, C. Y., McLoughlin, M. P., & Apuzzo, M. L. J. (2014) · World Neurosurgery · doi:10.1016/j.wneu.2014.03.012 · Cited by 17
Neuromodulation for Functional Electrical Stimulation
Wilson, R. D., Bryden, A. M., Kilgore, K. L., Makowski, N. S., Bourbeau, D. J., Kowalski, K. E., DiMarco, A. F., & Knutson, J. S. (2019) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2018.12.011 · Cited by 17
Self-citationRole of Functional Electrical Stimulation in Tetraplegia Hand Surgery
Bersch, I., & Fridén, J. O. (2016) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.01.035 · Cited by 17
“The freehand system was implanted in >250 persons with tetraplegia with a C5-6 lesion.(24) It was reported that all patients with implants had better grasp and release, greater pinch force, and activities of daily living independence.”
MethodGrasping Power by Means of Functional Electrical Stimulation in a Case of C6 Complete Tetraplegia
Shimada, Y., Chida, S., Matsunaga, T., Misawa, A., Ito, H., Sakuraba, T., Sato, M., Hatakeyama, K., & Itoi, E. (2003) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.201.91 · Cited by 17
Knutson, J. S., Hoyen, H. A., Kilgore, K. L., & Peckham, P. H. (2004) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.04.0053 · Cited by 17
“The system has been demonstrated to improve grasp strength, enable manipulation of objects of various sizes and weights, and increase independence in performing activities of daily living [8–11].”
BackgroundSelf-citationTate, D. G., Boninger, M. L., & Jackson, A. B. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.07.243 · Cited by 16
Bryden, A. M., Kilgore, K. L., Keith, M. W., & Peckham, P. H. (2008) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1304-37 · Cited by 16
Self-citationManagement of Upper Extremities in Tetraplegia: Current Concepts
Bednar, M. S., & Woodside, J. C. (2018) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-d-15-00465 · Cited by 16
Functional Electrical Stimulation in the 21st Century
Peckham, P. H., & Gorman, P. H. (2004) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/ppjq-cm9n-p80m-dedq · Cited by 16
Self-citationHeald, E., Kilgore, K. L., Hart, R. L., Moss, C. W., & Peckham, P. H. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0571-3 · Cited by 15
“The neuroprosthesis includes a receiver-stimulator implanted in the chest and eight epimysial electrodes implanted over muscles in the forearm and hand [5].”
Self-citationBottlenecks to clinical translation of direct brain-computer interfaces
Serruya, M. D. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00226 · Cited by 15
“From a practical engineering perspective it would be far better to have one or two degrees of freedom that could be decoded in a fast, reliable, technician-free manner, than seven degrees of freedom that were unreliable and required considerable external supervision to derive (Peckham et al., 2001; Rupp, 2014).”
BackgroundInfluentialAnderson, C. V., & Fuglevand, A. J. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00956.2007 · Cited by 16
“EMG signals were sampled at 2,000 samples ⅐ s Ϫ1 ⅐ channel Ϫ1 by a computerized data acquisition and control system (CED Power 1401, Cambridge , UK).”
HIGH SPEED TRANSCUTANEOUS OPTICAL TELEMETRY LINK
Ackermann, D. M. (2008) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 15
Knudsen, E. B., & Moxon, K. A. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00715 · Cited by 16
“…repetitive direct stimulation of the peripheral musculature recruits larger diameter fast-fatiguing muscle fibers before slowfatiguing ones (Enoka, 2002; Kern et al., 2002; Russ et al., 2002; Aguilar et al., 2010), which over time may reduce the functional efficacy of peripheral stimulation.”
BackgroundAn Implanted Upper Extremity Neuroprosthesis Utilizing Myoelectric Control
Kilgore, K. L., Peckham, P. H., Montague, F. W., Hart, R. L., Bryden, A. M., Keith, M. W., Hoyen, H. A., & Bhadra, N. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419634 · Cited by 15
Self-citationUse and evaluation of assistive technologies for upper limb function in tetraplegia
Readioff, R., Siddiqui, Z. K., Stewart, C., Fulbrook, L., O’Connor, R. J., & Chadwick, E. K. (2021) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2021.1878342 · Cited by 14
“26,32 The range of lateral pinch force with the device was 11.6 N to17 N, 22,29,32,33 palmar pinch force was 6.5 N to 10.4 N, 29,32,33 and finger grasp was 14.7 N. 32 The improvement of grasp and release function and strength of grips contributed to the increased success of the ADL tasks.”
BackgroundMethodInfluentialFattal, C. (2003) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/j.annrmp.2003.08.001 · Cited by 14
“[125] Peckham PH, Keith MW, Kilgore KL, Grill JH, Wuolle KS, Thrope GB, et al.”
BackgroundInfluentialRehabilitation of the Hand and Upper Extremity in Tetraplegia
Peljovich, A. E., Bryden, A. M., Malone, K. J., Hoyen, H. A., Hernandez-Gonzalez, E., & Keith, M. W. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-05602-1.00132-x · Cited by 14
Self-citationJiang, W., Zhao, T., Liu, H., Jia, R., Niu, D., Chen, B., Shi, Y., Yin, L., & Lu, B. (2018) · RSC Advances · doi:10.1039/c8ra00491a · Cited by 14
Powering strategies for implanted multi‐function neuroprostheses for spinal cord injury
Kilgore, K. L., Smith, B., Campean, A., Hart, R. L., Lambrecht, J. M., Buckett, J. R., & Peckham, P. H. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0113 · Cited by 14
Self-citationCreating a Reinforcement Learning Controller for Functional Electrical Stimulation of a Human Arm.
Thomas, P. S., Branicky, M. S., van den Bogert, A. J., & Jagodnik, K. M. (2008) · PubMed · Cited by 14
Knutson, J. S., Audu, M. L., & Triolo, R. J. (2006) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/9uu4-kl3v-cpl2-q7vf · Cited by 13
Neuromuscular Electrical Stimulation for Motor Restoration in Hemiparesis
Chae, J., & Yu, D. (2002) · Topics in Stroke Rehabilitation · doi:10.1310/rexb-akv9-2xbe-u5qa · Cited by 13
Neuromuscular electrical stimulation induced forelimb movement in a rodent model
Kanchiku, T., Lynskey, J. V., Protas, D. T., Abbas, J. J., & Jung, R. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.08.002 · Cited by 13
“…intramuscular and epimysial electrodes have been approved by the Federal Drug Administration, USA and been implanted for functional electrical stimulation in people with spinal cord injuries for long durations (Agarwal et al., 2003; Kobetic et al., 1999; Peckham et al., 2001; Sharma et al., 1998).”
BackgroundInfluentialAbreu, J., Crowder, D. C., & Kirsch, R. F. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3203970 · Cited by 12
“Many studies have demonstrated that FES can restore some 37 degree of upper-limb motor function to people with paral- 38 ysis [6], [7], [8], [9].”
BackgroundOby, E. R., Éthier, C., Bauman, M. J., Perreault, E. J., Ko, J. H., & Miller, L. E. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-375027-3.00011-9 · Cited by 12
Selzer, M. E., Clarke, S., Cohen, L. G., Kwakkel, G., & Miller, R. H. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995590.012 · Cited by 12
Neuromuscular Electrical Stimulation Applications
Knutson, J. S., Makowski, N. S., Kilgore, K. L., & Chae, J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-48323-0.00043-3 · Cited by 13
Self-citationSensor Modalities for Brain-Computer Interfacing
Schalk, G. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02577-8_67 · Cited by 12
Tetraplegia to Overground Stepping Using Non-Invasive Spinal Neuromodulation
Gad, P. N., Gerasimenko, Y., & Edgerton, V. R. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717096 · Cited by 11
“Even seemingly small improvements in UE function can have a significant impact on the quality of life of patients’ [12].”
BackgroundGarcía-Moreno, A., Comerma-Montells, A., Tudela-Pi, M., Minguillón, J., Becerra-Fajardo, L., & Ivorra, A. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac8dc4 · Cited by 12
“There are also instances of clinically demonstrated motor neuroprostheses with a few targets distributed over relatively large and mobile regions [4, 5].”
BackgroundRestoration of complex movement in the paralyzed upper limb
Hasse, B. A., Sheets, D. E. G., Holly, N. L., Gothard, K. M., & Fuglevand, A. J. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7ad7 · Cited by 14
Procházka, A. (2018) · Comprehensive physiology · doi:10.1002/cphy.c180006 · Cited by 15
“Though the technology was highly advanced and many recipients benefited significantly (225), the device was discontinued in 2002 (see Barriers section).”
Pellot-Cestero, J. E., Herring, E. Z., Graczyk, E. L., Memberg, W. D., Kirsch, R. F., Ajiboye, A. B., & Miller, J. P. (2023) · Neurosurgery · doi:10.1227/neu.0000000000002561 · Cited by 11
Rizzoglio, F., Altan, E., Ma, X., Bodkin, K. L., Dekleva, B. M., Solla, S. A., Kennedy, A., & Miller, L. E. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad038e · Cited by 12
“…to improve stance and walking (Granat et al 1993, Thrasher et al 2006, Daly et al 2011) as well as grasping (Peckham et al 1980, Snoek et al 2000, Peckham et al 2001, Popovic et al 2002) following stroke or SCI. Patients with C5-C6 SCI were able to use their preserved voluntary shoulder…”
BackgroundOttoboni, G., Porta, F. L., Piperno, R., Chattat, R., Bosco, A., Fattori, P., & Tessari, A. (2022) · PLoS ONE · doi:10.1371/journal.pone.0266702 · Cited by 11
STIMGRASP: A Home-Based Functional Electrical Stimulator for Grasp Restoration in Daily Activities
Barelli, R. G., Avelino, V. F., & Castro, M. C. F. (2022) · Sensors · doi:10.3390/s23010010 · Cited by 8
Sammut, S., Koh, R. G. L., & Zariffa, J. (2021) · Sensors · doi:10.3390/s21020506 · Cited by 9
Fattal, C., Teissier, J., Geffrier, A., da Fonseca, L. O., William, L., Andreu, D., Guiraud, D., & Coste, C. (2022) · Journal of Neurotrauma · doi:10.1089/neu.2021.0381 · Cited by 11
“In addition, it requires less energy, considerably decreases the number of implanted parts, and reduces the risk of complications 15 (infection, failure, and surgical risk through less invasive surgery).”
Sensors for motor neuroprostheses
Kilgore, K. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.3.401 · Cited by 5
Self-citationExploring selective neural electrical stimulation for upper limb function restoration
Tigra, W., Guiraud, D., Andreu, D., Coulet, B., Gélis, A., Fattal, C., Maciejasz, P., Picq, C. A., Rossel, O., Teissier, J., et al. (2016) · European Journal of Translational Myology · doi:10.4081/ejtm.2016.6035 · Cited by 8
“Moving paralyzed limbs after such trauma becomes possible [5]–[9].”
Neural Interfaces for Implanted Stimulators
Liu, X., Demosthenous, A., & Donaldson, N. (2011) · Springer eBooks · doi:10.1007/978-3-540-74658-4_37 · Cited by 8
Nason, S. R., Mender, M. J., Kennedy, E., Lambrecht, J. M., Kilgore, K. L., Chiravuri, S., Kumar, N. G., Kung, T. A., Willsey, M. S., Chestek, C. A., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/accf36 · Cited by 10
“By delivering electrical current to partially or completely non-functional musculature, commercial devices like the Freehand System [7, 8] have already been used with people with upper extremity paralysis to restore movement of native arms and hands.”
MethodSelf-citationBrain-machine interfaces for motor rehabilitation: Is recalibration important?
López-Larraz, E., Trincado-Alonso, F., & Montesano, L. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281203 · Cited by 11
“Different studies have successfully applied such devices for rehabilitation of paralyzed patients with spinal cord injury (SCI) or stroke [1], [2], [3].”
The impact of task context on predicting finger movements in a brain-machine interface
Mender, M. J., Nason, S. R., Temmar, H., Costello, J. T., Wallace, D. M., Willsey, M. S., Kumar, N. G., Kung, T. A., Patil, P. G., & Chestek, C. A. (2023) · eLife · doi:10.7554/elife.82598 · Cited by 7
Kleih, S. C., Lukito, S., & Kübler, A. (2012) · Ergonomics design and management · doi:10.1201/b13019-12 · Cited by 7
Orlin, M. N., Pierce, S. R., Laughton, C. A., Smith, B. T., Johnston, T. E., Shewokis, P. A., & McCarthy, J. J. (2007) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2005.tb01054.x · Cited by 7
Percutaneous Freehand™ System Intramuscular Electrode Placement
Hausman, M. R., & Masters, J. (2002) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.2002.0775 · Cited by 7
“Restoration of grasp and pinch profoundly improve the prospects for gainful employment and independence in critical tasks such as grooming, catheter maintenance and simple food preparation (Freehafer, 1998; Hashizume and Fukuji, 1994; Kiyono et al., 2000; Lo et al., 1998; Peckham et al., 2001).”
BackgroundFunctional electrical stimulation in neurorehabilitation
Gorman, P. H., Alon, G., & Peckham, P. H. (2006) · Cambridge University Press eBooks · doi:10.1017/cbo9780511545078.011 · Cited by 7
Self-citationDevelopment of less invasive neuromuscular electrical stimulation model for motor therapy in rodents
Kanchiku, T., Kato, Y., Suzuki, H., Imajo, Y., Yoshida, Y., Moriya, A., Taguchi, T., & Jung, R. (2012) · Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000009 · Cited by 6
Anderson, K. D., Bryden, A. M., & Moynahan, M. (2019) · Spinal Cord Series and Cases · doi:10.1038/s41394-019-0213-9 · Cited by 6
Rehabilitation in spinal cord injury
Cardenas, D. D., & Warms, C. A. (2006) · Cambridge University Press eBooks · doi:10.1017/cbo9780511545078.039 · Cited by 6
Cramer, S. C., & Nudo, R. J. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511777547.017 · Cited by 6
Flexible adaptation to an artificial recurrent connection from muscle to peripheral nerve in man
Kato, K. H., Sasada, S., & Nishimura, Y. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00143.2015 · Cited by 6
“…FES systems, the patient uses switches (Brandell 1982, Burridge et al. 1997) or muscle activity (Frigo et al. 2000; Muraoka 2002; O’Keeffe and Lyons 2002; Peckham et al. 2001; Popovic et al. 2001) to trigger preprogrammed patterned stimulation of paralyzed muscles to produce stereotyped movements.”
Backgroundda Fonseca, L. O., Bó, A. P. L., Guiraud, D., Navarro, B., Gélis, A., & Coste, C. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513418 · Cited by 6
Klein, C. S., Liu, H., Zhao, C. N., & Yang, X. (2021) · Spinal Cord · doi:10.1038/s41393-021-00653-1 · Cited by 6
Lyapunov-based Model Predictive Control of an Input Delayed Functional Electrical Simulation
Sun, Z., Bao, X., & Sharma, N. (2019) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2019.01.037 · Cited by 6
Functional Electrical Stimulation
Venkatasubramanian, G., Jung, R., & Sweeney, J. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd119 · Cited by 6
NEW-GENERATION FULLY PROGRAMMABLE CONTROLLER FOR FUNCTIONAL ELECTRICAL STIMULATION APPLICATIONS
Agnello, D. (2011) · TSpace (University of Toronto) · Cited by 6
Impaired Motor Function: Functional Electrical Stimulation
(2012) · Springer eBooks · doi:10.1007/springerreference_143732 · Cited by 6
Abreu, J., Crowder, D. C., & Kirsch, R. F. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3285983 · Cited by 5
Metadata
- Authors
- Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., Hentz, V. R., & Wiegner, A.
- Affiliations
- The University of Melbourne (AU)
- United States Department of Veterans Affairs (US)
- Venue
- Archives of Physical Medicine and Rehabilitation
- Publisher
- Elsevier BV
- Published
- 2001-10
- Volume
- 82
- Issue
- 10
- Pages
- 1380-1388
- ISSN
- 0003-9993 (ISSN-L)
- OpenAlex
- W2044493647
- Cited by
- 319
- References
- 36
- Citations by year
- 2026: 6 · 2025: 4 · 2024: 6 · 2023: 14 · 2022: 14 · 2021: 12 · 2020: 14 · 2019: 22 · 2018: 16 · 2017: 12 · 2016: 13 · 2015: 11 · 2014: 19 · 2013: 9 · 2012: 13
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Archives of Physical Medicine and Rehabilitation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Research Resources (M01RR000080, 5M01RR 00080)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- tetraplegia, spinal cord injury, hand grasp, grasp and release, tendon transfer, pinch strength, activities of daily living, user satisfaction, upper limb prosthesis
- MeSH terms
- Adult, Electric Stimulation, Electrodes, Implanted, Female, Follow-Up Studies, Hand, Humans, Male, Prosthesis Design, Quadriplegia, Cohort Studies, Hand Strength, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review