Improvements in GORE-TEX® vascular graft performance by Carmeda® bioactive surface heparin immobilization

Open access
Begovac, P.C., Thomson, R.C., Fisher, J.L., Hughson, A., Gällhagen, A.·2003·European Journal of Vascular and Endovascular Surgery

Abstract

Objectives a performance improvement in small-diameter bypass grafts remains a clinical objective. The purpose of the present investigation was to evaluate the potential of enhancing the thromboresistance of ePTFE grafts using a bioactive heparinized graft luminal surface in a canine model.Material and methods this study investigated the utility of heparin immobilization onto expanded polytetrafluoroethylene using Carmeda BioActive Surface technology (CBAS-ePTFE) as a means of improving vascular graft thromboresistance. Graft luminal surfaces were covered uniformly with the stably bound, end-point immobilized heparin.Results acute canine (5 greyhounds) interposition experiments comparing CBAS-ePTFE grafts to control ePTFE grafts showed that CBAS-ePTFE grafts remained patent and had significantly greater thrombus-free luminal surface (p<0.05). In a chronic canine (16 greyhounds) interposition experiment, significantly improved patency (p<0.05) was observed with CBAS-ePTFE grafts compared to controls. Long-term in vivo heparin bioactivity was demonstrated on CBAS-ePTFE grafts explanted between 1 and 12 weeks. On all CBAS-ePTFE grafts, heparin activity levels ranged from 15-25pmol/cm(2) and did not differ significantly (p>0.05).Discussion these results support the conclusion that a stable, CBAS-ePTFE surface provides improved thromboresistance and improved patency in canine interposition models. Maintenance of heparin catalytic activity on the graft surface in vivo likely contributes to this outcome and holds promise for the utility of this graft surface for clinical applications.

Integrity signals

Registry

Crossref · 10.1053/ejvs.2002.1909

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Begovac, P. C., Thomson, R. C., Fisher, J. L., Hughson, A., & Gällhagen, A.
Affiliations
W. L. Gore & Associates (United States) (US)
Corresponding author
Begovac, P.C.
Venue
European Journal of Vascular and Endovascular Surgery
Publisher
Elsevier BV
Published
2003-05
Volume
25
Issue
5
Pages
432-437
ISSN
1078-5884 (ISSN-L)
OpenAlex
W1966905436
Cited by
198
References
30
Citations by year
2026: 5 · 2025: 5 · 2024: 8 · 2023: 8 · 2022: 14 · 2021: 10 · 2020: 16 · 2019: 6 · 2018: 11 · 2017: 10 · 2016: 14 · 2015: 12 · 2014: 10 · 2013: 7 · 2012: 12
FWCI
3.32
Type
journal article
Language
en
Open access
Locations
  • European Journal of Vascular and Endovascular Surgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Health Sciences › Medicine › Surgery › Peripheral Artery Disease Management
Keywords
expanded polytetrafluoroethylene, heparin immobilization, graft patency, interposition graft
MeSH terms
Analysis of Variance, Animals, Anticoagulants, Blood Vessel Prosthesis, Dogs, Graft Occlusion, Vascular, Heparin, Microscopy, Electron, Scanning, Polytetrafluoroethylene, Surface Properties, Vascular Patency, Coated Materials, Biocompatible

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review