Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
AIM: Patients with recurrent syncope undiagnosed after extensive non-invasive and invasive testing pose a diagnostic and therapeutic dilemma. Holter monitoring is nondiagnostic in 90% of cases. Recent developments in loop recorder technology permit long-term ECG monitoring in patients with recurrent unexplained syncope. The aim of this study was to report the worldwide experience with a new subcutaneously implantable loop recorder, implanted in 133 patients with unexplained syncope and negative laboratory investigations. METHODS AND RESULTS: The implantable loop recorder monitors continuously a single lead electrogram using two sensing electrodes on the device shell. The device was implanted in 133 patients, 67 male and 66 female with recurrent syncope. During a mean follow-up of 10.8 +/- 4.3 months after device implantation, 83 patients (62%) experienced syncope or pre-syncope. In the remaining 50 patients no diagnosis could be made because either no events occurred, the patients were lost to follow-up, had adverse events, or died prior to diagnosis. In 72 of the 83 patients with syncope during follow-up (87%), loop recording definitively determined whether an arrhythmia was the cause of symptoms or not. Diagnosis included bradycardia in 21 patients, pacemaker dysfunction in one patient, and tachycardia in 10 patients. One patient experienced multiple rhythm disturbances. Syncope was non-arrhythmic in 40 patients. The remaining 11 patients failed to press the activator. Therapy was instituted in all patients, in whom an arrhythmic cause was found. Severe anticipated device related complications occurred in three patients. CONCLUSION: An implantable loop recorder is useful for establishing a diagnosis when symptoms are recurrent but too infrequent for conventional monitoring techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779 · cited 1×
“Despite a thorough non-invasive work-up, the aetiology cannot be clarified in 13%–48% of patients[1, 2 ].”
BackgroundEvaluation and outcome of emergency room patients with transient loss of consciousness
Day, S. C., Cook, E. F., Funkenstein, H., & Goldman, L. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90913-5 · Cited by 587
Evaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Prospective evaluation of syncope
Martin, G. J., Adams, S. L., Martin, H. G., Mathews, J., Zull, D., & Scanlon, P. J. (1984) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(84)80511-9 · Cited by 239
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
The etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Use of ambulatory electrocardiographic (Holter) monitoring
DiMarco, J. P., & Philbrick, J. T. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-1-53 · Cited by 177
Gulamhusein, S., Naccarelli, G. V., Ko, P. T., Prystowsky, E. N., Zipes, D. P., Barnett, H. J. M., Heger, J. J., & Klein, G. J. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90413-2 · Cited by 177
Self-citationLong-term prognosis of patients undergoing electrophysiologic studies for syncope of unknown origin
Bass, E. B., Elson, J. J., Fogoros, R. N., Peterson, J., Arena, V. C., & Kapoor, W. N. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)90257-3 · Cited by 103
Cited by
Blomstrom-Lundqvist (2003) · doi:10.1161/01.cir.0000091380.04100.84 · Cited by 955
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
BlomstromLundqvist, C. (2003) · European Heart Journal · doi:10.1016/j.ehj.2003.08.002 · Cited by 263
Cost implications of testing strategy in patients with syncope
Krahn, A. D., Klein, G. J., Yee, R., Hoch, J. S., & Skanes, A. C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00659-4 · Cited by 170
Use of implantable loop recorders in the diagnosis and management of syncope*1
FARWELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.010 · Cited by 132
Metadata
- Authors
- Seidl, K.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-07
- Volume
- 2
- Issue
- 3
- Pages
- 256-262
- ISSN
- 1099-5129 (ISSN-L)
- OpenAlex
- W2085626011
- Cited by
- 71
- References
- 11
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder. https://app.cochat.ai/papers/10.1053/eupc.2000.0108
- The paper
- Seidl, K. (2000). Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder. Europace. https://doi.org/10.1053/eupc.2000.0108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.