CoChat

Chronobiology of Arterial Hypertension in Hemodialysis Patients: Implications for Home Blood Pressure Monitoring

Open access
Agarwal, Rajiv, Light, Robert P. · 2009 · American Journal of Kidney Diseases
Cited by 54

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

Background Hemodialysis patients have a steady increase in blood pressure (BP) over the 44-hour interdialytic interval when ambulatory BP monitoring is used. Home BP recording allows for longer period of monitoring between dialysis and may better define the chronobiology of arterial hypertension. This study sought to determine the optimal time to perform home BP monitoring in hemodialysis patients to improve the strength of prediction of 44-hour interdialytic ambulatory BP. Study Design Diagnostic test study Setting and Participants This is an ancillary analysis of patients participating in the dry-weight reduction in hypertensive hemodialysis patients (DRIP) trial. Index test Home BP measured three times a day for one week using a validated oscillometric monitor on 3 occasions at 4 week intervals after randomization. Home BP measured during the first third, second third and last third of time elapsed after dialysis as well as each third of dialysis was compared to the overall ambulatory BP. Reference Tests Interdialytic ambulatory BP measured on 3 occasions at 4 week intervals after randomization. Results Over the interdialytic interval, we found an increase in systolic ambulatory BP of 0.30 ± 0.36 mmHg/hr and an increase in systolic home BP of 0.40 ± 0.25 mmHg/hr. This relationship in home BP reached a plateau after approximately 48 hrs. A similar pattern was seen for diastolic home BP. Probing dry-weight steepened the slope of ambulatory BP but did not alter the time-dependent relationship of home BP. Home BP was on average higher (bias) by 14.1 (95% CI 12.0 to 16.2)/5.7 (95% CI 4.6 to 6.9) mmHg. The standard deviation of differences between methods (precision) was 4.6/2.8 mmHg. Measurement of BP during each third of the interdialytic interval gave the best precision as measured by model fit compared to ambulatory BP measurements. Limitations Our cohort was overrepresented by African American hemodialysis patients. Whether African American participants have a different pattern of BP response than non-African American participants in the interdialytic period is not known. Conclusions Our findings suggest that time elapsed after dialysis must to be considered in interpreting the home BP recordings in hemodialysis patients. Home BP measured in each third of the interdialytic interval is likely to yield the most reliable BP estimate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.ajkd.2009.03.018

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 54

Metadata

Authors
Agarwal, R., & Light, R. P.
Venue
American Journal of Kidney Diseases
Publisher
Elsevier BV
Published
2009-10
Volume
54
Issue
4
Pages
693-701
ISSN
0272-6386 (ISSN-L)
OpenAlex
W1970813175
Cited by
47
References
26
FWCI
2.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.