Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 457

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Reliability and Initial Validation of the Ulcerative Colitis Endoscopic Index of Severity

Open access
Travis, Simon P.L., Schnell, Dan, Krzeski, Piotr, Abreu, Maria T., Altman, Douglas G., Colombel, Jean–Frédéric, Feagan, Brian G., Hanauer, Stephen B., Lichtenstein, Gary R., Marteau, Philippe R., Reinisch, Walter, Sands, Bruce E., Yacyshyn, Bruce R., Schnell, Patrick, Bernhardt, Christian A., Mary, Jean–Yves, Sandborn, William J.·2013·Gastroenterology

Abstract

BACKGROUND & AIMS: We studied the reliability of the previously described Ulcerative Colitis Endoscopic Index of Severity (UCEIS) and validated it with an independent cohort of investigators. METHODS: We created a new library of 57 videos of flexible sigmoidoscopy and stratified them based on disease severity. Twenty-five investigators were each randomly assigned to assess 28 videos (which included 4 duplicates to assess intraobserver reliability). Investigators were blinded to clinical details except for 2 of 4 duplicated videos (to assess the impact of knowledge of symptoms on assessment). Three descriptors ("vascular pattern", "bleeding", and "erosions and ulcers") comprising the UCEIS were scored with a visual analogue scale (VAS) to assess overall severity. Intrainvestigator and interinvestigator agreement was characterized by κ statistical analysis; reliability ratios were used to compare VAS and UCEIS scores. RESULTS: There was a high level of correlation between UCEIS scores and overall assessment of severity (correlation coefficient, 0.93). Internal consistency (Cronbach α analysis) was 0.86. Intrainvestigator and interinvestigator reliability ratios for UCEIS scores were 0.96 and 0.88, respectively. Intrainvestigator agreement in determination of the UCEIS score was good (κ = 0.72), with individual descriptors ranging from a κ of 0.47 (for bleeding) to 0.87 (for vascular pattern). Interinvestigator agreement in determination of UCEIS scores was moderate (κ = 0.50), with descriptors ranging from a κ of 0.48 (for bleeding) to 0.54 (for vascular pattern). Intrainvestigator variability in determining UCEIS scores did not change appreciably when a video was presented with clinical details. CONCLUSIONS: The UCEIS and its components show satisfactory intrainvestigator and interinvestigator reliability. Among investigators, the UCEIS accounted for a median of 86% of the variability in evaluation of overall severity on the VAS when assessing the endoscopic severity of UC and was unaffected by knowledge of clinical details.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.gastro.2013.07.024

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 457

Metadata

Authors
Travis, S. P. L., Schnell, D., Krzeski, P., Abreu, M. T., Altman, D. G., Colombel, J., Feagan, B. G., Hanauer, S. B., Lichtenstein, G. R., Marteau, P. R., Reinisch, W., Sands, B. E., Yacyshyn, B. R., Schnell, P., Bernhardt, C. A., Mary, J., & Sandborn, W. J.
Venue
Gastroenterology
Publisher
Elsevier BV
Published
2013-11
Volume
145
Issue
5
Pages
987-995
ISSN
0016-5085 (ISSN-L)
OpenAlex
W1996727874
Cited by
457
References
14
FWCI
17.80
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability and Initial Validation of the Ulcerative Colitis Endoscopic Index of Severity. https://app.cochat.ai/papers/10.1053/j.gastro.2013.07.024
The paper
Travis, S. P. L., Schnell, D., Krzeski, P., Abreu, M. T., Altman, D. G., Colombel, J., Feagan, B. G., Hanauer, S. B., Lichtenstein, G. R., Marteau, P. R., Reinisch, W., Sands, B. E., Yacyshyn, B. R., Schnell, P., Bernhardt, C. A., Mary, J., & Sandborn, W. J. (2013). Reliability and Initial Validation of the Ulcerative Colitis Endoscopic Index of Severity. Gastroenterology. https://doi.org/10.1053/j.gastro.2013.07.024

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.