Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery
Open accessAbstract
Objective The aim of this study was to compare deep body temperature obtained using a novel noninvasive continuous zero-heat-flux temperature measurement system with core temperatures obtained using conventional methods.Design A prospective, observational study.Setting Operating room of a university hospital.Participants The study comprised 15 patients undergoing vascular surgery of the lower extremities and 15 patients undergoing cardiac surgery with cardiopulmonary bypass.Interventions Zero-heat-flux thermometry on the forehead and standard core temperature measurements.Measurements and main results Body temperature was measured using a new thermometry system (SpotOn; 3M, St. Paul, MN) on the forehead and with conventional methods in the esophagus during vascular surgery (n = 15), and in the nasopharynx and pulmonary artery during cardiac surgery (n = 15). The agreement between SpotOn and the conventional methods was assessed using the Bland-Altman random-effects approach for repeated measures. The mean difference between SpotOn and the esophageal temperature during vascular surgery was+0.08°C (95% limit of agreement -0.25 to+0.40°C). During cardiac surgery, during off CPB, the mean difference between SpotOn and the pulmonary arterial temperature was -0.05°C (95% limits of agreement -0.56 to+0.47°C). Throughout cardiac surgery (on and off CPB), the mean difference between SpotOn and the nasopharyngeal temperature was -0.12°C (95% limits of agreement -0.94 to+0.71°C). Poor agreement between the SpotOn and nasopharyngeal temperatures was detected in hypothermia below approximately 32°C.Conclusions According to this preliminary study, the deep body temperature measured using the zero-heat-flux system was in good agreement with standard core temperatures during lower extremity vascular and cardiac surgery. However, agreement was questionable during hypothermia below 32°C.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The sensor probe applied to the forehead is a highly accurate surrogate compared to nasopharyngeal, esophageal and artery temperatures.
“Importantly, the sensor probe can be applied to the forehead, and has been shown to be highly accurate surrogate compared to nasopharyngeal20, esophageal23–27 and artery temperatures24.”
From Increased core body temperature in astronauts during long-duration space missions (2017) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Kurz, A. M., Sessler, D. I., & Lenhardt, R. (1996) · New England Journal of Medicine · doi:10.1056/nejm199605093341901 · Cited by 2,782 · see citing works
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 1,864 · see citing works
Perioperative Maintenance of Normothermia Reduces the Incidence of Morbid Cardiac Events
Frank, S. M. (1997) · JAMA · doi:10.1001/jama.1997.03540380041029 · Cited by 1,261 · see citing works
The Effects of Mild Perioperative Hypothermia on Blood Loss and Transfusion Requirement
Rajagopalan, S., Mascha, E. J., Na, J., & Sessler, D. I. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296719.73450.52 · Cited by 903 · see citing works
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758 · see citing works
Sessler, D. I., & Todd, M. M. (2000) · Anesthesiology · doi:10.1097/00000542-200002000-00042 · Cited by 556 · see citing works
Mild Intraoperative Hypothermia Prolongs Postanesthetic Recovery
Lenhardt, R., Marker, E., Goll, V., Tschernich, H. D., Kurz, A. M., Sessler, D. I., Narzt, E., & Lackner, F. X. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00009 · Cited by 555 · see citing works
Mackowiak, P. A. (1992) · JAMA · doi:10.1001/jama.268.12.1578 · Cited by 449 · see citing works
Mackowiak, P. A. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490120092034 · Cited by 419 · see citing works
Malignant Hyperthermia Deaths Related to Inadequate Temperature Monitoring, 2007–2012
Larach, M. G., Brandom, B. W., Allen, G. C., Gronert, G. A., & Lehman, E. B. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000421 · Cited by 213 · see citing works
A new technique for monitoring the deep body temperature in man from the intact skin surface.
Fox, R. H., & Solman, A. (1971) · PubMed · Cited by 179 · see citing works
A New Method for Monitoring Deep Body Temperature from the Skin Surface
Fox, R. H., Solman, A., Isaacs, R., Fry, A. J., & MacDonald, I. C. (1973) · Clinical Science · doi:10.1042/cs0440081 · Cited by 169 · see citing works
An Evaluation of a Zero-Heat-Flux Cutaneous Thermometer in Cardiac Surgical Patients
Eshraghi, Y., Nasr, V., Parra-Sánchez, I., et al. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000319 · Cited by 161 · see citing works
The Effects of Intraoperative Hypothermia on Surgical Site Infection
Seamon, M. J., Wobb, J., Gaughan, J. P., et al. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e31824b7e35 · Cited by 144 · see citing works
Billeter, A. T., Hohmann, S. F., Druen, D., Cannon, R. M., & Polk, H. C. (2014) · Surgery · doi:10.1016/j.surg.2014.04.024 · Cited by 128 · see citing works
Effects of preinduction and intraoperative warming during major laparotomy
Böck, M., Müller, J., Bach, A., et al. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.2.159 · Cited by 123 · see citing works
Non invasive physiological measurements
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90184-3 · Cited by 119 · see citing works
Grigore, A. M., Murray, C. F., Ramakrishna, H., & Djaiani, G. N. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181c04fea · Cited by 105 · see citing works
Karalapillai, D., Story, D., Calzavacca, P., et al. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2009.05989.x · Cited by 93 · see citing works
Noninvasive Temperature Monitoring in Postanesthesia Care Units
Langham, G., Maheshwari, A., Contrera, K. J., You, J., Mascha, E. J., & Sessler, D. I. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181a864ca · Cited by 77 · see citing works
Akata, T., Setoguchi, H., Shirozu, K., & Yoshino, J. (2007) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2006.11.031 · Cited by 75 · see citing works
Iden, T., Horn, E.-P., Bein, B., Böhm, R., Beese, J., & Höcker, J. (2015) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000232 · Cited by 73 · see citing works
Improvement of deep body thermometer for man
Kobayashi, T., Nemoto, T., Kamiya, A., & Togawa, T. (1975) · Annals of Biomedical Engineering · doi:10.1007/bf02363069 · Cited by 56 · see citing works
Webb, C. A.-J., Weyker, P. D., Moitra, V. K., et al. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182860fff · Cited by 46 · see citing works
(2015) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000344 · Cited by 44 · see citing works
Deep Body Thermometry during General Anesthesia
Muravchick, S. (1983) · Anesthesiology · doi:10.1097/00000542-198303000-00014 · Cited by 34 · see citing works
Evaluation of a newly developed monitor of deep body temperature
Yamakage, M., Iwasaki, S., & Namiki, A. (2002) · Journal of Anesthesia · doi:10.1007/s005400200056 · Cited by 31 · see citing works
Comparison of distal oesophageal temperature with “deep” and tracheal temperatures
Matsukawa, T., Sessler, D. I., Ozaki, M., Hanagata, K., Iwashita, H., & Kumazawa, T. (1997) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03014466 · Cited by 31 · see citing works
Deep temperature monitoring in intensive care
Togawa, T., Nemoto, T., Tsuji, T., et al. (1979) · Resuscitation · doi:10.1016/0300-9572(79)90015-7 · Cited by 25 · see citing works
Sato, H., Yamakage, M., Okuyama, K., et al. (2008) · European Journal of Anaesthesiology · doi:10.1017/s0265021508004602 · Cited by 23 · see citing works
Akata, T., Yamaura, K., Kandabashi, T., et al. (2004) · Journal of Anesthesia · doi:10.1007/s00540-003-0225-1 · Cited by 18 · see citing works
Noninvasive Determination of Core Temperature During Anesthesia
LEES, D. E., KIM, Y. D., & Macnamara, T. E. (1980) · Southern Medical Journal · doi:10.1097/00007611-198010000-00010 · Cited by 18 · see citing works
Brandes, I. F., Perl, T., Bauer, M., & Bräuer, A. (2014) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2014-0063 · Cited by 17 · see citing works
Accuracy and precision of “deep sternal” and tracheal temperatures at high- and low-fresh-gas flows
Matsukawa, T., Ozaki, M., Sessler, D. I., NISHIYAMA, T., Imamura, M., & Kumazawa, T. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/81.2.171 · Cited by 16 · see citing works
Singer, B., & Lipton, B. S. (1975) · PubMed · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Increased core body temperature in astronauts during long-duration space missions
Stahn, A. C., Werner, A., Opatz, O., Maggioni, M. A., Steinach, M., von Ahlefeld, V. W., Moore, A., Crucian, B. E., Smith, S. M., Zwart, S. R., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-15560-w · Cited by 100 · see citing works
- Authors
- Mäkinen, M.-T., Pesonen, A., Jousela, I., Päivärinta, J., Poikajärvi, S., Albäck, A., Salminen, U.-S., & Pesonen, E.
- Affiliations
- University of Helsinki (FI)
- Corresponding author
- Mäkinen, Marja-Tellervo
- Venue
- Journal of Cardiothoracic and Vascular Anesthesia
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 30
- Issue
- 4
- Pages
- 973-978
- ISSN
- 1053-0770 (ISSN-L)
- OpenAlex
- W2514700268
- Cited by
- 69
- References
- 35
- Citations by year
- 2026: 8 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 9 · 2021: 6 · 2020: 9 · 2019: 15 · 2018: 11 · 2017: 2
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- Journal of Cardiothoracic and Vascular Anesthesia (publishedVersion)
- PubMed (publishedVersion)
- Työväentutkimus Vuosikirja (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
- Keywords
- deep body temperature, core body temperature, cardiac surgery, cardiopulmonary bypass, hypothermia, esophageal temperature, pulmonary artery temperature, nasopharyngeal temperature, non-invasive temperature measurement
- MeSH terms
- Aged, Body Temperature, Female, Cardiac Surgical Procedures, Humans, Male, Middle Aged, Prospective Studies, Vascular Surgical Procedures, Monitoring, Intraoperative, Lower Extremity, Thermometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review