CoChat

Multimodality Imaging: Beyond PET/CT and SPECT/CT

Open access
Cherry, Simon R. · 2009 · Seminars in Nuclear Medicine
Cited by 238

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar potential to impact medical science and clinical medicine? The combination of PET or SPECT with MRI is an area of active research at the present time, while other, perhaps less obvious combinations, including CT/MR and PET/optical also are being studied. In addition to the integration of the instrumentation, there are parallel developments in synthesizing imaging agents that can be viewed by multiple imaging modalities. Is the fusion of PET and SPECT with CT the ultimate answer in multimodality imaging, or is it just the first example of a more general trend towards harnessing the complementary nature of the different modalities on integrated imaging platforms?

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.semnuclmed.2009.03.001

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Image registration methods: a survey

    Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423 · cited 1×

    “Prior to the advent of multimodality PET/CT and SPECT/CT scanners this was accomplished, almost exclusively, through retrospective software registration of the volumetric datasets [17,18].”
    Method
  • Photoacoustic imaging in biomedicine

    Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700 · cited 1×

    “Uniquely, this hybrid technology relies on the interaction of two imaging modalities, optical imaging and ultrasonic imaging, to take advantage of the high spatial localization capabilities of ultrasound at depth in tissues, and the high sensitivity provided by optical contrast [48,49].”
    Background
  • Medical image registration

    Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093

  • Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging

    Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854 · cited 1×

    “In animal models, this technique allows very high spatial resolution functional and molecular imaging to be obtained at depths of several mm beneath the surface [50].”
  • A combined PET/CT scanner for clinical oncology.

    Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659

  • Simultaneous PET-MRI: a new approach for functional and morphological imaging

    Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981 · cited 2×

    “Two MR-compatible PET scanners based on avalanche photodiode detector technology have been developed for small animal imaging and have been successfully applied for a range of in vivo applications [22,23].”
    BackgroundSelf-citation
  • In Vivo Magnetic Resonance Detection of Cancer by Using Multifunctional Magnetic Nanocrystals

    Huh, Y.-M., Jun, Y.-W., Song, H.-T., Kim, S., Choi, J.-S., Lee, J.-H., Yoon, S., Kim, K.-S., Shin, J.-S., Suh, J.-S., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052337c · Cited by 859 · cited 1×

    “Examples include fluorescent quantum dots with a paramagnetic coating [52], quantum dots with high native relaxivity [53], lipoproteins incorporating iron oxide nanoparticles and quantum dots [54], liposomes containing Gd and fluorescent agents [55] and antibodies conjugated with both nanoparticles and fluorescent age…”
    Background
  • Prospects of photoacoustic tomography

    Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561 · cited 1×

    “Uniquely, this hybrid technology relies on the interaction of two imaging modalities, optical imaging and ultrasonic imaging, to take advantage of the high spatial localization capabilities of ultrasound at depth in tissues, and the high sensitivity provided by optical contrast [48,49].”
    Background
  • MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration

    Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495 · cited 1×

    “MRIbased attenuation correction has therefore become an active area of research [27,28] and its success or otherwise will likely have an important bearing on the ultimate range of clinical applications for PET/MRI.”
    Background
  • Quantum Dots with a Paramagnetic Coating as a Bimodal Molecular Imaging Probe

    Mulder, W. J. M., Koole, R., Brandwijk, R. J., Storm, G., Chin, P. T. K., Strijkers, G. J., de Mello Donegá, C., Nicolay, K., & Griffioen, A. W. (2006) · Nano Letters · doi:10.1021/nl051935m · Cited by 482 · cited 1×

    “Examples include fluorescent quantum dots with a paramagnetic coating [52], quantum dots with high native relaxivity [53], lipoproteins incorporating iron oxide nanoparticles and quantum dots [54], liposomes containing Gd and fluorescent agents [55] and antibodies conjugated with both nanoparticles and fluorescent age…”
    Background

Show all 41 references

Cited by

Metadata

Authors
Cherry, S. R.
Venue
Seminars in Nuclear Medicine
Publisher
Elsevier BV
Published
2009-09
Volume
39
Issue
5
Pages
348-353
ISSN
0001-2998 (ISSN-L)
OpenAlex
W2056106477
Cited by
238
References
41
FWCI
15.50
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.