The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Knee stability and graft function following anterior cruciate ligament reconstruction: Comparison between 11 o'clock and 10 o'clock femoral tunnel placement
Abstract
PURPOSE: To study how well an anterior cruciate ligament (ACL) graft fixed at the 10 and 11 o'clock positions can restore knee function in response to both externally applied anterior tibial and combined rotatory loads by comparing the biomechanical results with each other and with the intact knee. TYPE OF STUDY: Biomechanical experiment using human cadaveric specimens. METHODS: Ten human cadaveric knees (age, 41+/-13 years) were reconstructed by placing a bone-patellar tendon-bone graft at the 10 and 11 o'clock positions, in a randomized order, and then tested using a robotic/universal force-moment sensor testing system. Two external loading conditions were applied: (1) 134 N anterior tibial load with the knee at full extension, 15 degrees, 30 degrees, 60 degrees, and 90 degrees of flexion, and (2) a combined rotatory load of 10 N-m valgus and 5 N-m internal tibial torque with the knee at 15 degrees and 30 degrees of flexion. The resulting kinematics of the reconstructed knee and in situ forces in the ACL graft were determined for each femoral tunnel position. RESULTS: In response to a 134-N anterior tibial load, anterior tibial translation (ATT) for both femoral tunnel positions was not significantly different from the intact knee except at 90 degrees of knee flexion as well as at 60 degrees of knee flexion for the 10 o'clock position. There was no significant difference in the ATT between the 10 and 11 o'clock positions, except at 90 degrees of knee flexion. Under a combined rotatory load, however, the coupled ATT for the 11 o'clock position was approximately 130% of that for the intact knee at 15 degrees and 30 degrees of flexion. For the 10 o'clock position, the coupled ATT was not significantly different from the intact knee at 15 degrees of flexion and approximately 120% of that for the intact knee at 30 degrees of flexion. Coupled ATT for the 10 o'clock position was significantly smaller than for the 11 o'clock position at 15 degrees and 30 degrees of flexion. The in situ force in the ACL graft was also significantly higher for the 10 o'clock position than the 11 o'clock position at 30 degrees of flexion in response to the same loading condition (70 +/- 18 N v 60 +/- 15 N, respectively). CONCLUSIONS: The 10 o'clock position more effectively resists rotatory loads when compared with the 11 o'clock position as evidenced by smaller ATT and higher in situ force in the graft. Despite the fact that ACL grafts placed at the 10 or 11 o'clock positions are equally effective under an anterior tibial load, neither femoral tunnel position was able to fully restore knee stability to the level of the intact knee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cruciate Ligaments of the Knee Joint: Anatomical. Functional and Experimental Analysis
Girgis, F. G., Marshall, J. L., & MONA JEM, A. R. S. A. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197501000-00033 · Cited by 1,485
Biomechanical Analysis of an Anatomic Anterior Cruciate Ligament Reconstruction
Yagi, M., Wong, E. K., Kanamori, A., Debski, R. E., Fu, F. H., & Woo, S. L.-Y. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300050501 · Cited by 988
Self-citationFemoral insertion of the ACL. Radiographic quadrant method.
Bernard, M., Hertel, P., Hornung, H., & Cierpinski, T. (1997) · PubMed · Cited by 634
Functional anatomy of the anterior cruciate ligament and a rationale for reconstruction.
Odensten, M., & Gillquist, J. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567020-00012 · Cited by 614
Effects of postmortem storage by freezing on ligament tensile behavior
Woo, S. L.-Y., Orlando, C. A., Camp, J. F., & Akeson, W. H. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90016-3 · Cited by 572
Self-citationCurrent Trends in Anterior Cruciate Ligament Reconstruction
Fu, F. H., Bennett, C. H., Lattermann, C., & Ma, C. B. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270062501 · Cited by 564
Self-citationSakane, M., Fox, R. J., Glen, S. L. W., Livesay, A., Li, G., & Fu, F. H. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150219 · Cited by 559
Self-citationFu, F. H., Bennett, C. H., Ma, C. B., Menetrey, J., & Lattermann, C. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280010801 · Cited by 412
Self-citationThe treatment of injuries of the anterior cruciate ligament.
Johnson, R. J., Beynnon, B. D., Nichols, C. E., & Renstrom, P. A. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274010-00020 · Cited by 319
Kanamori, A., Woo, S. L.-Y., Ma, C. B., Zeminski, J., Rudy, T. W., Li, G., & Livesay, G. A. (2000) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2000.7682 · Cited by 316
Self-citationBiomechanics of Knee Ligaments
Woo, S. L.-Y., Debski, R. E., Withrow, J. D., & Janaushek, M. A. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270042301 · Cited by 293
Self-citationA combined robotic/universal force sensor approach to determine in situ forces of knee ligaments
Rudy, T. W., Livesay, G. A., Woo, S. L., & Fu, F. H. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00056-5 · Cited by 279
Self-citationAnterior cruciate ligament: functional anatomy of its bundles in rotatory instabilities
Norwood, L. A., & Cross, M. J. (1979) · The American Journal of Sports Medicine · doi:10.1177/036354657900700106 · Cited by 243
Single– versus two–femoral socket anterior cruciate ligament reconstruction technique
Mae, T., Shino, K., Miyama, T., Shinjo, H., Ochi, T., Yoshikawa, H., & Fujie, H. (2001) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2001.25250 · Cited by 240
Fujie, H., Livesay, G. A., Woo, S. L.-Y., Kashiwaguchi, S., & Blomstrom, G. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2792266 · Cited by 233
Self-citationSapega, A. A., Moyer, R. A., Schneck, C., & Komalahiranya, N. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072020-00015 · Cited by 224
The anterior cruciate ligament. A functional analysis based on postmortem studies
Furman, W., Marshall, J., & Girgis, F. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658020-00003 · Cited by 217
Arthroscopically Assisted Reconstruction of the Anterior Cruciate Ligament: A Follow-up Report
O'Neill, D. B. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200109000-00006 · Cited by 183
Fuss, F. K. (1989) · American Journal of Anatomy · doi:10.1002/aja.1001840208 · Cited by 166
Livesay, G. A., Fujie, H., Kashiwaguchi, S., Morrow, D. A., Fu, F. H., & Woo, S. L. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584446 · Cited by 155
Self-citationThe anterior cruciate ligament
(1975) · Injury · doi:10.1016/0020-1383(75)90216-8 · Cited by 145
Tsuda, E., Fukuda, Y., Loh, J. C., Debski, R. E., Fu, F. H., & Woo, S. L. (2002) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/jars.2002.36112 · Cited by 93
Self-citationHöher, J., Kanamori, A., Zeminski, J., Fu, F. H., & Woo, S. L. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290061601 · Cited by 66
Self-citationMüller, W. (1996) · International Orthopaedics · doi:10.1007/s002640050076 · Cited by 50
Cited by
Zantop, T., Herbort, M., Raschke, M. J., Fu, F. H., & Petersen, W. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506294571 · Cited by 515
Self-citationYamamoto, Y., Hsu, W.-H., Woo, S. L.-Y., Van Scyoc, A. H., Takakura, Y., & Debski, R. E. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546504263947 · Cited by 364
Self-citationZantop, T., Wellmann, M., Fu, F. H., & Petersen, W. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546507308361 · Cited by 344
Self-citationDomb, B. G., Philippon, M. J., & Giordano, B. D. (2013) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2012.04.057 · Cited by 331
Järvelä, T. (2007) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-006-0254-z · Cited by 312
Metadata
- Authors
- Loh, J. C., Fukuda, Y., Tsuda, E., Steadman, R. J., Fu, F. H., & Woo, S. L.-Y.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2003-03
- Volume
- 19
- Issue
- 3
- Pages
- 297-304
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W1982282724
- Cited by
- 706
- References
- 24
- FWCI
- 22.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.