The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
The extracellular matrix, interstitial fluid and ions as a mechanical signal transducer in articular cartilage
Open accessAbstract
OBJECTIVE: (1) Provide an overview of the biomechanical factors that are required to analyze and interpret biological data from explant experiments; (2) Present a description of some of the mechano-electrochemical events which occur in cartilage explants during loading. DESIGN: A thorough and provocative discussion on the effects of loading on articular cartilage will be presented. Five simplest loading cases are considered: hydrostatic pressure, osmotic pressure, permeation (pressure loading), confined compression and unconfined compression. Details of how such surface loadings are converted or transduced by the extracellular matrix (ECM) to pressure, fluid, solute and ion flows, deformation and electrical fields are discussed. RESULTS: Similarities and differences in these quantities for the five types of loading are specifically noted. For example, it is noted that there is no practical mechanical loading condition that can be achieved in the laboratory to produce effects that are equal to the effects of osmotic pressure loading within the ECM. Some counter-intuitive effects from these loadings are also described. Further, the significance of flow-induced compression of the ECM is emphasized, since this frictional drag effect is likely to be one of the major effects of fluid flow through the porous-permeable ECM. Streaming potentials arising from the flow of ions past the fixed charges of the ECM are discussed in relation to the flow-induced compaction effect as well. CONCLUSION: Understanding the differences among these explant loading cases is important; it will help to provide greater insights to the mechano-electrochemical events which mediate metabolic responses of chondrocytes in explant loading experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Self-citationProteoglycans: many forms and many functions
Hardingham, T. E., & Fosang, A. J. (1992) · The FASEB Journal · doi:10.1096/fasebj.6.3.1740236 · Cited by 1,195
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024
Self-citationBiosynthetic response of cartilage explants to dynamic compression
Sah, R. L. ‐., Kim, Y., Doong, J. H., Grodzinsky, A. J., Plass, A. H. K., & Sandy, J. D. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070502 · Cited by 875
The Theory of Membrane Equilibria.
Donnan, F. G. (1924) · Chemical Reviews · doi:10.1021/cr60001a003 · Cited by 807
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770
Self-citationBiomechanics: motion, flow, stress, and growth
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2130 · Cited by 729
Balance between swelling pressure and collagen tension in normal and degenerate cartilage
MAROUDAS, A. (1976) · Nature · doi:10.1038/260808a0 · Cited by 726
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623
An Analysis of the Unconfined Compression of Articular Cartilage
Armstrong, C. G., Lai, W. M., & Mow, V. C. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138475 · Cited by 552
Self-citation
Cited by
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
O’Conor, C. J., Leddy, H. A., Benefield, H. C., Liedtke, W. B., & Guilak, F. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1319569111 · Cited by 487
Guilak, F., & Mow, V. C. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00105-6 · Cited by 471
Self-citationLi, W.-J., Mauck, R. L., Cooper, J. A., Yuan, X., & Tuan, R. S. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.004 · Cited by 400
GUILAK, F., ALEXOPOULOS, L. G., UPTON, M. L., YOUN, I., CHOI, J. B., CAO, L., SETTON, L. A., & HAIDER, M. A. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1346.011 · Cited by 357
Metadata
- Authors
- Mow, V. C., Wang, C. C., & Hung, C. T.
- Venue
- Osteoarthritis and Cartilage
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 7
- Issue
- 1
- Pages
- 41-58
- ISSN
- 1063-4584 (ISSN-L)
- OpenAlex
- W2077741258
- Cited by
- 298
- References
- 43
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The extracellular matrix, interstitial fluid and ions as a mechanical signal transducer in articular cartilage. https://app.cochat.ai/papers/10.1053/joca.1998.0161
- The paper
- Mow, V. C., Wang, C. C., & Hung, C. T. (1999). The extracellular matrix, interstitial fluid and ions as a mechanical signal transducer in articular cartilage. Osteoarthritis and Cartilage. https://doi.org/10.1053/joca.1998.0161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.