The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
The extracellular matrix, interstitial fluid and ions as a mechanical signal transducer in articular cartilage
Open accessAbstract
OBJECTIVE: (1) Provide an overview of the biomechanical factors that are required to analyze and interpret biological data from explant experiments; (2) Present a description of some of the mechano-electrochemical events which occur in cartilage explants during loading. DESIGN: A thorough and provocative discussion on the effects of loading on articular cartilage will be presented. Five simplest loading cases are considered: hydrostatic pressure, osmotic pressure, permeation (pressure loading), confined compression and unconfined compression. Details of how such surface loadings are converted or transduced by the extracellular matrix (ECM) to pressure, fluid, solute and ion flows, deformation and electrical fields are discussed. RESULTS: Similarities and differences in these quantities for the five types of loading are specifically noted. For example, it is noted that there is no practical mechanical loading condition that can be achieved in the laboratory to produce effects that are equal to the effects of osmotic pressure loading within the ECM. Some counter-intuitive effects from these loadings are also described. Further, the significance of flow-induced compression of the ECM is emphasized, since this frictional drag effect is likely to be one of the major effects of fluid flow through the porous-permeable ECM. Streaming potentials arising from the flow of ions past the fixed charges of the ECM are discussed in relation to the flow-induced compaction effect as well. CONCLUSION: Understanding the differences among these explant loading cases is important; it will help to provide greater insights to the mechano-electrochemical events which mediate metabolic responses of chondrocytes in explant loading experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Self-citationProteoglycans: many forms and many functions
Hardingham, T. E., & Fosang, A. J. (1992) · The FASEB Journal · doi:10.1096/fasebj.6.3.1740236 · Cited by 1,195
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024
Self-citationBiosynthetic response of cartilage explants to dynamic compression
Sah, R. L. ‐., Kim, Y., Doong, J. H., Grodzinsky, A. J., Plass, A. H. K., & Sandy, J. D. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070502 · Cited by 875
The Theory of Membrane Equilibria.
Donnan, F. G. (1924) · Chemical Reviews · doi:10.1021/cr60001a003 · Cited by 807
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770
Self-citationBiomechanics: motion, flow, stress, and growth
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2130 · Cited by 729
Balance between swelling pressure and collagen tension in normal and degenerate cartilage
MAROUDAS, A. (1976) · Nature · doi:10.1038/260808a0 · Cited by 726
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623
An Analysis of the Unconfined Compression of Articular Cartilage
Armstrong, C. G., Lai, W. M., & Mow, V. C. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138475 · Cited by 552
Self-citationOn Residual Stresses in Arteries
Chuong, C. J., & Fung, Y. C. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138600 · Cited by 546
Soltz, M. A., & Ateshian, G. A. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00105-5 · Cited by 504
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 499
Chondrocyte deformation and local tissue strain in articular cartilage: A confocal microscopy study
Guilak, F., Ratcliffe, A., & Mow, V. C. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130315 · Cited by 475
Self-citationThe nonlinear characteristics of soft gels and hydrated connective tissues in ultrafiltration
Holmes, M. H., & Mow, V. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90007-p · Cited by 458
Self-citationCompression-induced changes in the shape and volume of the chondrocyte nucleus
Guilak, F. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00100-x · Cited by 404
Biophysical chemistry of cartilaginous tissues with special reference to solute and fluid transport1
Maroudas, A. (1975) · Biorheology · doi:10.3233/bir-1975-123-416 · Cited by 380
THE PERMEABILITY OF ARTICULAR CARTILAGE
Maroudas, A., Bullough, P., Swanson, S. A. V., & Freeman, M. A. R. (1968) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.50b1.166 · Cited by 350
Mechanical Regulation of Cartilage Biosynthetic Behavior: Physical Stimuli
Kim, Y. J., Sah, R. L. Y., Grodzinsky, A. J., Plaas, A. H. K., & Sandy, J. D. (1994) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1994.1201 · Cited by 344
A Molecular Model of Proteoglycan-Associated Electrostatic Forces in Cartilage Mechanics
Buschmann, M. D., & Grodzinsky, A. J. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2796000 · Cited by 331
Drag-induced compression of articular cartilage during a permeation experiment1
Lai, W. M., & Mow, V. C. (1980) · Biorheology · doi:10.3233/bir-1980-171-213 · Cited by 321
Self-citationFrank, E. H., & Grodzinsky, A. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90282-x · Cited by 301
Palmoski, M., Perricone, E., & Brandt, K. D. (1979) · Arthritis & Rheumatism · doi:10.1002/art.1780220511 · Cited by 299
Frank, E. H., & Grodzinsky, A. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90283-1 · Cited by 283
Stockwell, R. A. (1979) · Cambridge University Press eBooks · Cited by 275
Kim, Y.-J., Bonassar, L. J., & Grodzinsky, A. J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00159-2 · Cited by 272
Gu, W. Y., Lai, W. M., & Mow, V. C. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798299 · Cited by 270
Self-citationSwelling pressure of the inervertebral disc: Influence of proteoglycan and collagen contents
Urban, J. P. G., & McMullin, J. F. (1985) · Biorheology · doi:10.3233/bir-1985-22205 · Cited by 243
Setton, L. A., Mow, V. C., Müller, F. J., Pita, J. C., & Howell, D. S. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120402 · Cited by 227
Self-citationMovement and composition of interstitial fluid of cartilage
Linn, F. C., & Sokoloff, L. (1965) · Arthritis & Rheumatism · doi:10.1002/art.1780080402 · Cited by 217
Hou, J. S., Holmes, M. H., Lai, W. M., & Mow, V. C. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168343 · Cited by 215
Self-citationAteshian, G. A., & Wang, H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00008-6 · Cited by 206
Schneiderman, R., Keret, D., & Maroudas, A. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040402 · Cited by 198
Maroudas, A., & Bannon, C. (1981) · Biorheology · doi:10.3233/bir-1981-183-624 · Cited by 196
Ateshian, G. A., Wang, H., & Lai, W. M. (1998) · Journal of Tribology · doi:10.1115/1.2834416 · Cited by 192
Elementary Mechanics of the Endothelium of Blood Vessels
Fung, Y. C., & Liu, S. Q. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895465 · Cited by 185
Schinagl, R. M., Ting, M. K., Price, J. H., & Sah, R. L. (1996) · Annals of Biomedical Engineering · doi:10.1007/bf02648112 · Cited by 164
Gu, W. Y., Lai, W. M., & Mow, V. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90034-c · Cited by 156
Self-citationDas, P., Schurman, D. J., & Smith, R. L. (1997) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100150113 · Cited by 133
Holmes, M. H., Lai, W. M., & Mow, V. C. (1985) · Journal of Biomechanical Engineering · doi:10.1115/1.3138545 · Cited by 106
Self-citationSwelling and Curling Behaviors of Articular Cartilage
Setton, L. A., Tohyama, H., & Mow, V. C. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798002 · Cited by 97
Self-citationMow, V. C., Ateshian, G. A., Lai, W. M., et al. (1998) · International Journal of Solids and Structures · doi:10.1016/s0020-7683(98)00103-6 · Cited by 75
Self-citationStress, Strain, Pressure and Flow Fields in Articular Cartilage and Chondrocytes
Mow, V. C., Bachrach, N. M., Setton, L. A., et al. (1994) · Springer eBooks · doi:10.1007/978-1-4613-8425-0_20 · Cited by 73
Self-citation
Cited by
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Biomechanical factors in osteoarthritis
Guilak, F. (2011) · Best Practice & Research Clinical Rheumatology · doi:10.1016/j.berh.2011.11.013 · Cited by 594
O’Conor, C. J., Leddy, H. A., Benefield, H. C., Liedtke, W. B., & Guilak, F. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1319569111 · Cited by 487
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
Self-citationGuilak, F., & Mow, V. C. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00105-6 · Cited by 471
Self-citation
Metadata
- Authors
- Mow, V. C., Wang, C. C., & Hung, C. T.
- Venue
- Osteoarthritis and Cartilage
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 7
- Issue
- 1
- Pages
- 41-58
- ISSN
- 1063-4584 (ISSN-L)
- OpenAlex
- W2077741258
- Cited by
- 298
- References
- 43
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.