The DOI matches its Crossref record; 199 of the 199 references it cites were found in a registry or an index.
Advanced imaging for detection and differentiation of colorectal neoplasia: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2019
Open accessAbstract
Main Recommendations: 1 ESGE suggests that high definition endoscopy, and dye or virtual chromoendoscopy, as well as add-on devices, can be used in average risk patients to increase the endoscopist’s adenoma detection rate. However, their routine use must be balanced against costs and practical considerations. Weak recommendation, high quality evidence. 2 ESGE recommends the routine use of high definition systems in individuals with Lynch syndrome. Strong recommendation, high quality evidence. 3 ESGE recommends the routine use, with targeted biopsies, of dye-based pancolonic chromoendoscopy or virtual chromoendoscopy for neoplasia surveillance in patients with long-standing colitis. Strong recommendation, moderate quality evidence. 4 ESGE suggests that virtual chromoendoscopy and dye-based chromoendoscopy can be used, under strictly controlled conditions, for real-time optical diagnosis of diminutive (≤ 5 mm) colorectal polyps and can replace histopathological diagnosis. The optical diagnosis has to be reported using validated scales, must be adequately photodocumented, and can be performed only by experienced endoscopists who are adequately trained, as defined in the ESGE curriculum, and audited. Weak recommendation, high quality evidence. 5 ESGE recommends the use of high definition white-light endoscopy in combination with (virtual) chromoendoscopy to predict the presence and depth of any submucosal invasion in nonpedunculated colorectal polyps prior to any treatment. Strong recommendation, moderate quality evidence. 6 ESGE recommends the use of virtual or dye-based chromoendoscopy in addition to white-light endoscopy for the detection of residual neoplasia at a piecemeal polypectomy scar site. Strong recommendation, moderate quality evidence. 7 ESGE suggests the possible incorporation of computer-aided diagnosis (detection and characterization of lesions) to colonoscopy, if acceptable and reproducible accuracy for colorectal neoplasia is demonstrated in high quality multicenter in vivo clinical studies. Possible significant risks with implementation, specifically endoscopist deskilling and over-reliance on artificial intelligence, unrepresentative training datasets, and hacking, need to be considered. Weak recommendation, low quality evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-performance medicine: the convergence of human and artificial intelligence
Topol, E. J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0300-7 · Cited by 10,450 · cited 3×
“It seems likely that such systems will have a major place in clinical practice in the future, with more than 20 systems, in particular in radiology and pathology, having received regulatory approval [219].”
BackgroundGrading quality of evidence and strength of recommendations
(2004) · BMJ · doi:10.1136/bmj.328.7454.1490 · Cited by 8,477
The well-built clinical question: A key to evidence-based decisions
(1995) · ACP Journal Club · doi:10.7326/acpjc-1995-123-3-a12 · Cited by 2,931 · cited 1×
“Key questions were formulated using patient, intervention, comparator, outcome (PICO) methodology [8].”
MethodAdenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Quality Indicators for Colonoscopy and the Risk of Interval Cancer
Kaminski, M. F., Regula, J., Kraszewska, E., Polkowski, M., Wojciechowska, U., Didkowska, J., Zwierko, M., Rupinski, M., Nowacki, M. P., & Butruk, E. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907667 · Cited by 2,010
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
Pickhardt, P. J., Choi, J. R., Hwang, I., Butler, J. A., Puckett, M. L., Hildebrandt, H. A., Wong, R. K., Nugent, P. A., Mysliwiec, P. A., & Schindler, W. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031618 · Cited by 1,972
Lieberman, D. A., Rex, D. K., Winawer, S. J., Giardiello, F. M., Johnson, D. A., & Levin, T. R. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.06.001 · Cited by 1,892
Cairns, S. R., Scholefield, J. H., Steele, R. J., Dunlop, M. G., Thomas, H. J. W., Evans, G. D., Eaden, J. A., Rutter, M. D., Atkin, W. P., Saunders, B. P., et al. (2010) · Gut · doi:10.1136/gut.2009.179804 · Cited by 1,141
Unintended consequences of machine learning in medicine
Cabitza, F., Rasoini, R., & Gensini, G. F. (2017) · JAMA · doi:10.1001/jama.2017.7797 · Cited by 1,066
Kaminski, M., Thomas-Gibson, S., Bugajski, M., Bretthauer, M., Rees, C., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., et al. (2017) · Endoscopy · doi:10.1055/s-0043-103411 · Cited by 885
Self-citation
Cited by
Pimentel-Nunes, P., Libânio, D., Bastiaansen, B. A. J., Bhandari, P., Bisschops, R., Bourke, M. J., Esposito, G., Lemmers, A., Maselli, R., Messmann, H., et al. (2022) · Endoscopy · doi:10.1055/a-1811-7025 · Cited by 808
Self-citationHassan, C., Spadaccini, M., Iannone, A., Maselli, R., Jovani, M., Chandrasekar, V. T., Antonelli, G., Yu, H., Areia, M., Dinis-Ribeiro, M., et al. (2021) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.059 · Cited by 529
Self-citationHassan, C., Antonelli, G., Dumonceau, J.-M., Regula, J., Bretthauer, M., Chaussade, S., Dekker, E., Ferlitsch, M., Gimeno-Garcia, A., Jover, R., et al. (2020) · Endoscopy · doi:10.1055/a-1185-3109 · Cited by 515
Self-citationECCO Guidelines on Inflammatory Bowel Disease and Malignancies
Gordon, H., Biancone, L., Fiorino, G., Katsanos, K. H., Kopylov, U., Al Sulais, E., Axelrad, J. E., Balendran, K., Burisch, J., de Ridder, L., et al. (2023) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjac187 · Cited by 317
Self-citationBudzyń, K., Romańczyk, M., Kitala, D., Kołodziej, P., Bugajski, M., Adami, H. O., Blom, J., Buszkiewicz, M., Halvorsen, N., Hassan, C., et al. (2025) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(25)00133-5 · Cited by 313
Self-citationFerlitsch, M., Hassan, C., Bisschops, R., Bhandari, P., Dinis-Ribeiro, M., Risio, M., Paspatis, G. A., Moss, A., Libânio, D., Lorenzo-Zúñiga, V., et al. (2024) · Endoscopy · doi:10.1055/a-2304-3219 · Cited by 311
Self-citationImpact of artificial intelligence on miss rate of colorectal neoplasia
Wallace, M. B., Sharma, P., Bhandari, P., East, J., Antonelli, G., Lorenzetti, R., Vieth, M., Speranza, I., Spadaccini, M., Desai, M., et al. (2022) · Gastroenterology · doi:10.1053/j.gastro.2022.03.007 · Cited by 273
Self-citationArtificial Intelligence in Colorectal Cancer Screening, Diagnosis and Treatment. A New Era
Mitsala, A., Tsalikidis, C., Pitiakoudis, M., Simopoulos, C., & Tsaroucha, A. K. (2021) · Current Oncology · doi:10.3390/curroncol28030149 · Cited by 271
Murthy, S. K., Feuerstein, J. D., Nguyen, G. C., & Velayos, F. S. (2021) · Gastroenterology · doi:10.1053/j.gastro.2021.05.063 · Cited by 267
Xu, H., Tang, R. S. Y., Lam, T. Y. T., Zhao, G., Lau, J. Y. W., Liu, Y., Wu, Q., Rong, L., Xu, W., Li, X., et al. (2023) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2022.07.006 · Cited by 209
Rondonotti, E., Hassan, C., Tamanini, G., Antonelli, G., Andrisani, G., Leonetti, G., Paggi, S., Amato, A., Scardino, G., Di Paolo, D., et al. (2023) · Endoscopy · doi:10.1055/a-1852-0330 · Cited by 128
Self-citationArtificial Intelligence Allows Leaving-In-Situ Colorectal Polyps
Hassan, C., Balsamo, G., Lorenzetti, R., Zullo, A., & Antonelli, G. (2022) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2022.04.045 · Cited by 119
Self-citationSato, Y., Tsujinaka, S., Miura, T., Kitamura, Y., Suzuki, H., & Shibata, C. (2023) · Cancers · doi:10.3390/cancers15164154 · Cited by 111
“Several international societies provide guidance on techniques for surveillance colonoscopy (Table 2) [8,38,47,51,52].”
BackgroundHouwen, B. B. S. L., Hassan, C., Coupé, V. M. H., Greuter, M. J. E., Hazewinkel, Y., Vleugels, J. L. A., Antonelli, G., Bustamante-Balén, M., Coron, E., Cortas, G. A., et al. (2022) · Endoscopy · doi:10.1055/a-1689-5130 · Cited by 99
Self-citationA novel AI device for real-time optical characterization of colorectal polyps
Biffi, C., Salvagnini, P., Dinh, N. N., Hassan, C., Sharma, P., GI Genius CADx Study Group, Antonelli, G., Awadie, H., Bernhofer, S., Carballal, S., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00633-6 · Cited by 54
“…visual differentiation between adenomatous and non-adenomatous polyps (optical characterization, OC) during colonoscopy is clinically relevant to select optimal treatment regimen, avoid inappropriate endoscopic resection, improve cost-effectiveness, and reduce the number of polypectomies 3,4 .”
BackgroundSelf-citationScreening and Surveillance of Colorectal Cancer: A Review of the Literature
Maida, M., Dahiya, D. S., Shah, Y. R., Tiwari, A., Gopakumar, H., Vohra, I., Khan, A., Jaber, F., Ramai, D., & Facciorusso, A. (2024) · Cancers · doi:10.3390/cancers16152746 · Cited by 43
“Thus far, studies have yielded promising results and may lead to more efficient surveillance, particularly in high-risk IBD patients [122,123].”
ResultPEACE: Perception and Expectations toward Artificial Intelligence in Capsule Endoscopy
Leenhardt, R., Fernandez-Urien Sainz, I., Rondonotti, E., Toth, E., Van de Bruaene, C., Baltes, P., Rosa, B., Triantafyllou, K., Histace, A., Koulaouzidis, A., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10235708 · Cited by 30
Next-generation endoscopy in inflammatory bowel disease
Zammarchi, I., Santacroce, G., & Iacucci, M. (2023) · Diagnostics · doi:10.3390/diagnostics13152547 · Cited by 28
Self-citationColorectal cancer screening in Lynch syndrome: Indication, techniques and future perspectives
Perrod, G., Rahmi, G., & Cellier, C. (2021) · Digestive Endoscopy · doi:10.1111/den.13702 · Cited by 28
Polyp characterization using deep learning and a publicly accessible polyp video database
Kader, R., Cid‐Mejias, A., Brandao, P., Islam, S., Hebbar, S., Puyal, J. G., Ahmad, O. F., Hussein, M., Toth, D., Mountney, P., et al. (2023) · Digestive Endoscopy · doi:10.1111/den.14500 · Cited by 22
Metadata
- Authors
- Bisschops, R., East, J. E., Hassan, C., Hazewinkel, Y., Kamiński, M. F., Neumann, H., Pellisé, M., Antonelli, G., Bustamante Balen, M., Coron, E., Cortas, G., Iacucci, M., Yuichi, M., Longcroft-Wheaton, G., Mouzyka, S., Pilonis, N., Puig, I., van Hooft, J. E., & Dekker, E.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2019-11-11
- Volume
- 51
- Issue
- 12
- Pages
- 1155-1179
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W4230531790
- Cited by
- 340
- References
- 199
- FWCI
- 15.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.