The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2020
Open accessAbstract
Main Recommendations: The following recommendations for post-polypectomy colonoscopic surveillance apply to all patients who had one or more polyps that were completely removed during a high quality baseline colonoscopy. 1 ESGE recommends that patients with complete removal of 1 – 4 < 10 mm adenomas with low grade dysplasia, irrespective of villous components, or any serrated polyp < 10 mm without dysplasia, do not require endoscopic surveillance and should be returned to screening. Strong recommendation, moderate quality evidence. If organized screening is not available, repetition of colonoscopy 10 years after the index procedure is recommended.Strong recommendation, moderate quality evidence. 2 ESGE recommends surveillance colonoscopy after 3 years for patients with complete removal of at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia. Strong recommendation, moderate quality evidence. 3 ESGE recommends a 3 – 6-month early repeat colonoscopy following piecemeal endoscopic resection of polyps ≥ 20 mm. Strong recommendation, moderate quality evidence. A first surveillance colonoscopy 12 months after the repeat colonoscopy is recommended to detect late recurrence. Strong recommendation, high quality evidence. 4 If no polyps requiring surveillance are detected at the first surveillance colonoscopy, ESGE suggests to perform a second surveillance colonoscopy after 5 years. Weak recommendation, low quality evidence. After that, if no polyps requiring surveillance are detected, patients can be returned to screening. 5 ESGE suggests that, if polyps requiring surveillance are detected at first or subsequent surveillance examinations, surveillance colonoscopy may be performed at 3 years. Weak recommendation, low quality evidence. A flowchart showing the recommended surveillance intervals is provided (Fig. 1).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305 · cited 2×
“According to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology adopted for ESGE guidelines [2, 3], a hierarchy across outcomes must be created, and the main recommendations should be based on SOURCE AND SCOPE”
MethodInternational Agency for Research on Cancer
National Cancer Institute (2020) · Definitions · doi:10.32388/pfg7jq · Cited by 9,435
Grading quality of evidence and strength of recommendations
(2004) · BMJ · doi:10.1136/bmj.328.7454.1490 · Cited by 8,477
The well-built clinical question: A key to evidence-based decisions
(1995) · ACP Journal Club · doi:10.7326/acpjc-1995-123-3-a12 · Cited by 2,931
Lieberman, D. A., Rex, D. K., Winawer, S. J., Giardiello, F. M., Johnson, D. A., & Levin, T. R. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.06.001 · Cited by 1,892
Ferlitsch, M., Moss, A., Hassan, C., Bhandari, P., Dumonceau, J.-M., Paspatis, G., Jover, R., Langner, C., Bronzwaer, M., Nalankilli, K., et al. (2017) · Endoscopy · doi:10.1055/s-0043-102569 · Cited by 1,108
Self-citationKaminski, M., Thomas-Gibson, S., Bugajski, M., Bretthauer, M., Rees, C., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., et al. (2017) · Endoscopy · doi:10.1055/s-0043-103411 · Cited by 885
Self-citationNCCN Guidelines Insights: Colon Cancer, Version 2.2018
Benson, A. B., Venook, A. P., Al-Hawary, M. M., Cederquist, L., Chen, Y.-J., Ciombor, K. K., Cohen, S., Cooper, H. S., Deming, D., Engstrom, P. F., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0021 · Cited by 806
Incomplete Polyp Resection During Colonoscopy—Results of the Complete Adenoma Resection (CARE) Study
Pohl, H., Srivastava, A., Bensen, S. P., Anderson, P., Rothstein, R. I., Gordon, S. R., Levy, L. C., Toor, A., Mackenzie, T. A., Rosch, T., et al. (2013) · Gastroenterology · doi:10.1053/j.gastro.2012.09.043 · Cited by 757
Zhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660
Cited by
Rondonotti, E., Hassan, C., Tamanini, G., Antonelli, G., Andrisani, G., Leonetti, G., Paggi, S., Amato, A., Scardino, G., Di Paolo, D., et al. (2023) · Endoscopy · doi:10.1055/a-1852-0330 · Cited by 128
Self-citationArtificial Intelligence Allows Leaving-In-Situ Colorectal Polyps
Hassan, C., Balsamo, G., Lorenzetti, R., Zullo, A., & Antonelli, G. (2022) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2022.04.045 · Cited by 119
Self-citationHouwen, B. B. S. L., Hassan, C., Coupé, V. M. H., Greuter, M. J. E., Hazewinkel, Y., Vleugels, J. L. A., Antonelli, G., Bustamante-Balén, M., Coron, E., Cortas, G. A., et al. (2022) · Endoscopy · doi:10.1055/a-1689-5130 · Cited by 99
Self-citationLi, J. W., Wu, C. C. H., Lee, J. W. J., Liang, R., Soon, G. S. T., Wang, L. M., Koh, X. H., Koh, C. J., Chew, W. D., Lin, K. W., et al. (2023) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000002282 · Cited by 61
Hassan, C., Sharma, P., Mori, Y., Bretthauer, M., Rex, D. K., Spadaccini, M., Selvaggio, C., Antonelli, G., Khalaf, K., Rizkala, T., et al. (2023) · Gastroenterology · doi:10.1053/j.gastro.2022.10.021 · Cited by 46
Self-citation
Metadata
- Authors
- Hassan, C., Antonelli, G., Dumonceau, J.-M., Regula, J., Bretthauer, M., Chaussade, S., Dekker, E., Ferlitsch, M., Gimeno-Garcia, A., Jover, R., Kalager, M., Pellisé, M., Pox, C., Ricciardiello, L., Rutter, M., Helsingen, L. M., Bleijenberg, A., Senore, C., van Hooft, J. E., Dinis-Ribeiro, M., & Quintero, E.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2020-06-22
- Volume
- 52
- Issue
- 08
- Pages
- 687-700
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W3037959220
- Cited by
- 515
- References
- 78
- FWCI
- 20.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2020. https://app.cochat.ai/papers/10.1055/a-1185-3109
- The paper
- Hassan, C., Antonelli, G., Dumonceau, J.-M., Regula, J., Bretthauer, M., Chaussade, S., Dekker, E., Ferlitsch, M., Gimeno-Garcia, A., Jover, R., Kalager, M., Pellisé, M., Pox, C., Ricciardiello, L., Rutter, M., Helsingen, L. M., Bleijenberg, A., Senore, C., van Hooft, J. E., . . . Quintero, E. (2020). Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2020. Endoscopy. https://doi.org/10.1055/a-1185-3109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.