Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 515

The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.

Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2020

Open access
Hassan, Cesare, Antonelli, Giulio, Dumonceau, Jean-Marc, Regula, Jaroslaw, Bretthauer, Michael, Chaussade, Stanislas, Dekker, Evelien, Ferlitsch, Monika, Gimeno-Garcia, Antonio, Jover, Rodrigo, Kalager, Mette, Pellisé, Maria, Pox, Christian, Ricciardiello, Luigi, Rutter, Matthew, Helsingen, Lise Mørkved, Bleijenberg, Arne, Senore, Carlo, van Hooft, Jeanin E., Dinis-Ribeiro, Mario, Quintero, Enrique·2020·Endoscopy

Abstract

Main Recommendations: The following recommendations for post-polypectomy colonoscopic surveillance apply to all patients who had one or more polyps that were completely removed during a high quality baseline colonoscopy. 1 ESGE recommends that patients with complete removal of 1 – 4 < 10 mm adenomas with low grade dysplasia, irrespective of villous components, or any serrated polyp < 10 mm without dysplasia, do not require endoscopic surveillance and should be returned to screening. Strong recommendation, moderate quality evidence. If organized screening is not available, repetition of colonoscopy 10 years after the index procedure is recommended.Strong recommendation, moderate quality evidence. 2 ESGE recommends surveillance colonoscopy after 3 years for patients with complete removal of at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia. Strong recommendation, moderate quality evidence. 3 ESGE recommends a 3 – 6-month early repeat colonoscopy following piecemeal endoscopic resection of polyps ≥ 20 mm. Strong recommendation, moderate quality evidence. A first surveillance colonoscopy 12 months after the repeat colonoscopy is recommended to detect late recurrence. Strong recommendation, high quality evidence. 4 If no polyps requiring surveillance are detected at the first surveillance colonoscopy, ESGE suggests to perform a second surveillance colonoscopy after 5 years. Weak recommendation, low quality evidence. After that, if no polyps requiring surveillance are detected, patients can be returned to screening. 5 ESGE suggests that, if polyps requiring surveillance are detected at first or subsequent surveillance examinations, surveillance colonoscopy may be performed at 3 years. Weak recommendation, low quality evidence. A flowchart showing the recommended surveillance intervals is provided (Fig. 1).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/a-1185-3109

Cites

78 of 78 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 78 references

Cited by

See all 515

Metadata

Authors
Hassan, C., Antonelli, G., Dumonceau, J.-M., Regula, J., Bretthauer, M., Chaussade, S., Dekker, E., Ferlitsch, M., Gimeno-Garcia, A., Jover, R., Kalager, M., Pellisé, M., Pox, C., Ricciardiello, L., Rutter, M., Helsingen, L. M., Bleijenberg, A., Senore, C., van Hooft, J. E., Dinis-Ribeiro, M., & Quintero, E.
Venue
Endoscopy
Published
2020-06-22
Volume
52
Issue
08
Pages
687-700
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W3037959220
Cited by
515
References
78
FWCI
20.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2020. https://app.cochat.ai/papers/10.1055/a-1185-3109
The paper
Hassan, C., Antonelli, G., Dumonceau, J.-M., Regula, J., Bretthauer, M., Chaussade, S., Dekker, E., Ferlitsch, M., Gimeno-Garcia, A., Jover, R., Kalager, M., Pellisé, M., Pox, C., Ricciardiello, L., Rutter, M., Helsingen, L. M., Bleijenberg, A., Senore, C., van Hooft, J. E., . . . Quintero, E. (2020). Post-polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2020. Endoscopy. https://doi.org/10.1055/a-1185-3109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.