GLP-1 receptor agonist use does not increase risk of respiratory complications post-endoscopy
Open accessAbstract
Data on respiratory complications associated with GLP-1 receptor agonist (GLP-1 RA) use before endoscopic procedures are limited. We conducted a retrospective cohort study using TriNetX in adults with diabetes or obesity on GLP-1 RAs within 3 months of endoscopy, comparing them with non-GLP-1 RA users. Propensity score matching and Cox proportional hazards models were used to assess outcomes. Among 46,948 patients, no significant differences in post-endoscopy aspiration pneumonitis (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.54–1.56) or pneumonia (HR 1.01, 95% CI 0.83–1.24) were found between groups. GLP-1 RA use before endoscopy does not increase respiratory complications, supporting continued preoperative medication use.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Population-based studies have reported mixed findings on the potential association between GLP-1RA use and aspiration pneumonia.
“Population-based studies have reported mixed findings on the potential association between GLP-1RA use and aspiration pneumonia (39–44).”
From The science of safety: adverse effects of GLP-1 receptor agonists as glucose-lowering and obesity medications (2026) · cites this paper as [44]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
GLP-1 receptor agonists in the treatment of type 2 diabetes - state-of-the-art
Nauck, M. A., Quast, D. R., Wefers, J., & Meier, J. J. (2021) · Molecular Metabolism · doi:10.1016/j.molmet.2020.101102 · Cited by 1,647 · see citing works
Glucagon-Like Peptide-1 Receptor Agonist Use and Residual Gastric Content Before Anesthesia
Sen, S., Potnuru, P. P., Hernandez, N., Goehl, C., Praestholm, C., Sridhar, S., & Nwokolo, O. O. (2024) · JAMA Surgery · doi:10.1001/jamasurg.2024.0111 · Cited by 202 · see citing works
Hashash, J. G., Thompson, C. C., & Wang, A. Y. (2024) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2023.11.002 · Cited by 140 · see citing works
Yeo, Y. H., Gaddam, S., Ng, W. H., Huang, P.-C., Mohamed, G., Samaan, J., Yi-Jin Hsieh, T., Lee, G. Y., Watson, R., Mathur, R., et al. (2024) · Gastroenterology · doi:10.1053/j.gastro.2024.03.015 · Cited by 128 · see citing works
Flagged first, then by citations
Research works printed but not linked: 5
- [1]Garvey WT Mechanick JI Brett EM American Association of Clinical Endocrinologists and American College of Endocrinology comprehensive clinical practice guidelines for medical care of patients with obesity Endocr Pract 2016 22 842 884 27472012
- [7]Tewfik GL Rodriguez-Aponte C Zhang K Outcomes and disposition of patients after case cancellation on day of surgery for reasons attributed to medial or anesthetic care: A retrospective cohort analysis Anesth Analg 2022 35 845 854 35913700
- [8]Childers CP Maggard-Gibbons M Understanding costs of care in the operating room JAMA Surg 2018 153 e176233 10.1001/jamasurg.2017.6233 29490366 PMC5875376 · DOI
- [9]von Elm E Altman DG Egger M The strengthening the reporting of observational studies in epidemiology (STROBE) statement: Guidelines for reporting observational studies J Clin Epidemiol 2008 61 344 349 10.1016/S0140-6736(07)61602-X 18313558 · DOI · Paper page
- [10]Dixit AA Bateman BT Hawn MT Preoperative GLP-1 receptor agonist use and risk of postoperative respiratory complications JAMA 2024 331 1672 1673 10.1001/jama.2024.5003 38648036 PMC11036309 · DOI · Paper page
Cited by
Sorted by citations
Jalleh, R. J., Talley, N. J., Horowitz, M., & Nauck, M. A. (2026) · Journal of Clinical Investigation · doi:10.1172/jci194740 · Cited by 40 · see citing works
“Population-based studies have reported mixed findings on the potential association between GLP-1RA use and aspiration pneumonia (39– 44).”
- Authors
- Velji-Ibrahim, J., Nathani, P., Patel, H. K., & Sharma, P.
- Affiliations
- Prisma Health (US)
- University of Kansas Medical Center (US)
- Corresponding author
- Velji-Ibrahim, Jena
- Venue
- Endoscopy International Open
- Publisher
- Georg Thieme Verlag KG
- Published
- 2024-11-25
- Volume
- 13
- Issue
- CP
- Pages
- a24872937-a24872937
- ISSN
- 2196-9736 (ISSN-L)
- 2364-3722
- PMC
- PMC11827728
- OpenAlex
- W4404732549
- Cited by
- 6
- References
- 4
- Citations by year
- 2026: 3 · 2025: 3
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Endoscopy International Open (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac, Anesthesia and Surgical Outcomes
- Keywords
- GLP-1 receptor agonists, respiratory complications, preoperative medication use, diabetes mellitus, obesity, endoscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review