Reflections on the Topics: EEG Frequency Bands and Regulation of Vigilance
The DOI matches its Crossref record.
Abstract
A critical analysis of quantitative pharmaco-electroencephalography begins with parametrization into variables. The determination of frequency bands according to clinical criteria should be reconsidered. Alternatives may be the determination of factor scores or the definition of frequency bands based on factor analysis. If the latter procedure is used, the clinical α-band is subdivided into a lower (α F 1 = 8,5–10.5 Hz) and an upper (α F 2 = 10.5–12.5 Hz) part. Furthermore parts of the clinical ϑ-band (and the δ-band are combined into the δ F -band (1.5–6.0 Hz), for awake healthy volunteers with an occipital α-rhythm. Existing concepts of vigilance for the awake stages are not contradictory to the following observations: the factor structure of EEG relative power spectrum variables shows a negative correlation of slow α-frequencies with those in the δ F - and β F 3 -band. There is also a negative correlation between slow and fast α-wave relative power values. Zusammenfassung Die kritische Betrachtung der quantitativen Pharmakoelektroenzephalographie beginnt mit der Parameterbildung. Die bisher übliche Frequenzbandeinteilung nach klinischen Kriterien sollte überdacht werden. Mögliche Alternativen sind die Faktorscorebildung oder eine Frequenzbanddefinition mittels Faktorenanalyse. Bei Anwendung des letzteren Verfahrens überrascht besonders die Unterteilung des klinischen α-Bandes in einen unteren (α F 1 = 8,5–10,5 Hz) und einen oberen (α F 2 = 10,5–12,5 Hz) Anteil, sowie die Zusammenfassung des δ-Bandes mit dem unteren ϑ-Bereich zu einem gemeinsamen δ F (1,5–6,0 Hz)-Band. Es bestehen negative Korrelationen zwischen den relativen Poweranteilen des langsamen α F 1 Bandes und dem α F - sowie dem β F 2 -Band. Fernerhin besteht eine negative Korrelation zwischen relativen Poweranteilen des langsamen mit denen des schnellen α-Bandes. Diese Zusammenhänge stehen nicht in Widerspruch zu bekannten Vigilanzkonzepten. Entscheidend für das Verständnis des EEG in Zusammenhang mit klinisch-physiologischen Befunden ist zudem eine stärkere Betrachtung des Faktors Vigilanz und seine Aufgliederung in eine quantitative vertikale und eine qualitative horizontale Bewertungsachse. Bei einer eindimensionalen Betrachtung muß es zu Fehlbeurteilungen der Vigilanztiefe kommen, da die Reaktionsreizstärke (Weckreiz- oder Zuwendungsreizstärke) der gemeinsame Parameter für beide Achsen ist.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pascual-Marqui, R. D., Lehmann, D., Koenig, T., Kochi, K., Merlo, M. C. G., Hell, D., & Koukkou, M. (1999) · Psychiatry Research: Neuroimaging · doi:10.1016/s0925-4927(99)00013-x · Cited by 617
Lehmann, C., Koenig, T., Jelic, V., Prichep, L., John, R. E., Wahlund, L.-O., Dodge, Y., & Dierks, T. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.023 · Cited by 324
Frontal Brain Asymmetry and Reward Responsiveness: A Source-Localization Study
Pizzagalli, D. A., Sherwood, R. J., Henriques, J. B., & Davidson, R. J. (2005) · Psychological Science · doi:10.1111/j.1467-9280.2005.01618.x · Cited by 324
The status of spectral EEG abnormality as a diagnostic test for schizophrenia
Boutros, N. N., Arfken, C., Galderisi, S., Warrick, J., Pratt, G., & Iacono, W. (2008) · Schizophrenia Research · doi:10.1016/j.schres.2007.11.020 · Cited by 322
BOLD correlates of EEG alpha phase-locking and the fMRI default mode network
Jann, K., Dierks, T., Boesch, C., Kottlow, M., Strik, W., & Koenig, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.001 · Cited by 286
“Furthermore, the distinction between lower and upper alpha often found in the literature (Fink et al., 2005; Herrmann et al., 1978a,b; Klimesch, 1997; Kubicki et al., 1979) seems to be justified and reasonable even in the study of the brain's resting state.”
BackgroundFunctional brain network efficiency predicts intelligence
Langer, N., Pedroni, A., Gianotti, L. R. R., Hänggi, J., Knoch, D., & Jäncke, L. (2012) · Human Brain Mapping · doi:10.1002/hbm.21297 · Cited by 282
Friedberg, M. H., Lee, S. M., & Ebner, F. F. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.5.2243 · Cited by 276
Rossini, P. M., Di Iorio, R., Vecchio, F., Anfossi, M., Babiloni, C., Bozzali, M., Bruni, A. C., Cappa, S. F., Escudero, J., Fraga, F. J., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.03.003 · Cited by 233
Pizzagalli, D. A., Nitschke, J. B., Oakes, T. R., Hendrick, A. M., Horras, K. A., Larson, C. L., Abercrombie, H. C., Schaefer, S. M., Koger, J. V., Benca, R. M., et al. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01313-6 · Cited by 211
“In light of the observation that EEG frequency bands reflect different functions and behave statistically independently (Kubicki et al 1979), Low Resolution Electromagnetic Tomography (LORETA) (Pascual-Marqui et al 1994, 1999) was used to estimate the three-dimensional intracerebral current density…”
Baumgartner, T., Valko, L., Esslen, M., & Jäncke, L. (2006) · CyberPsychology & Behavior · doi:10.1089/cpb.2006.9.30 · Cited by 205
Connectome: Graph theory application in functional brain network architecture
Vecchio, F., Miraglia, F., & Maria Rossini, P. (2017) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2017.09.003 · Cited by 202
“…nodes (Pascual-Marqui, 2007a; Pascual-Marqui et al., 2011), was individually computed between all possible pairs of ROIs for each EEG frequency band (Kubicki et al., 1979; Niedermeyer and da Silva, 2005): delta (2–4 Hz), theta (4–8 Hz), alpha 1 (8–10.5 Hz), alpha 2 (10.5–13 Hz), beta 1 (13–20…”
MethodInfluentialVecchio, F., Miraglia, F., Marra, C., Quaranta, D., Vita, M. G., Bramanti, P., & Rossini, P. M. (2014) · Journal of Alzheimer's Disease · doi:10.3233/jad-132087 · Cited by 182
“Among the eLORETA current density time series of the 84 ROIs, intracortical Lagged Linear Coherence, extracted by “all nearest voxels” method [76, 77], was computed between all possible pairs of the 84 ROIs for each of the seven independent EEG frequency bands [78, 79] of delta (2–4 Hz), theta (4–8 Hz), alpha 1 (8–10.”
The effects of working memory training on functional brain network efficiency
Langer, N., von Bastian, C. C., Wirz, H., Oberauer, K., & Jäncke, L. (2013) · Cortex · doi:10.1016/j.cortex.2013.01.008 · Cited by 176
“The absolute power spectra were integrated in the following independent frequency bands following classification proposed by Kubicki et al. (1979): delta (1.5e6 Hz), theta (6.5e8 Hz), alpha1 (8.5e10 Hz), alpha2 (10.5e12 Hz), beta1 (12.5e18 Hz), beta2 (18.5e21 Hz), beta3 (21.5e30 Hz), and gamma…”
BackgroundMethodFrei, E., Gamma, A., Pascual‐Marqui, R., Lehmann, D., Hell, D., & Vollenweider, F. X. (2001) · Human Brain Mapping · doi:10.1002/hbm.1049 · Cited by 173
“Because EEG spectral frequency bands are known to reflect different functions and behave statistically independent, the analysis was done separately in the following seven bands [Kubicki et al., 1979]: Delta (1.”
BackgroundInfluentialKoenig, T., Lehmann, D., Saito, N., Kuginuki, T., Kinoshita, T., & Koukkou, M. (2001) · Schizophrenia Research · doi:10.1016/s0920-9964(00)00154-7 · Cited by 169
Source localization of EEG activity during hypnotically induced anxiety and relaxation
Isotani, T., Tanaka, H., Lehmann, D., Pascual-Marqui, R. D., Kochi, K., Saito, N., Yagyu, T., Kinoshita, T., & Sasada, K. (2001) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(00)00197-5 · Cited by 165
Lehmann, D., Faber, P. L., Tei, S., Pascual-Marqui, R. D., Milz, P., & Kochi, K. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.042 · Cited by 150
“…2007; PascualMarqui et al., 2011) was computed between all possible 171 pairs of the 19 ROIs for each of the eight independent EEG frequency bands (Kubicki et al., 1979; Niedermeyer and Lopes da Silva, 2005 p. 1234) of delta (1.5-6 Hz), theta (6.5-8 Hz), alpha-1 (8.5-10 Hz), alpha-2: (10.5-12…”
MethodInfluentialMiraglia, F., Vecchio, F., Bramanti, P., & Rossini, P. M. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.07.040 · Cited by 150
Vecchio, F., Miraglia, F., Alù, F., Menna, M., Judica, E., Cotelli, M., & Rossini, P. M. (2020) · Journal of Alzheimer’s Disease · doi:10.3233/jad-200171 · Cited by 73
Chapotot, F., Buguet, A., Gronfier, C., & Brandenberger, G. (2001) · Neuroendocrinology · doi:10.1159/000054648 · Cited by 72
“and quantitative analysis of the serial waking EEG were performed with the ERA-Profiler ® 2.1 software package (PhiTools ® , Grenoble, France). Artefacts (eye blinks, movements and electrode detachments) were detected through combining digital filtering and background-dependent amplitude thresholds and were subsequent…”
MethodInfluentialKamaradova, D., Prasko, J., Taborsky, J., Grambal, A., Latalova, K., Hajda, M., Ociskova, M., Brunovsky, M., & Hlustik, P. (2016) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s93040 · Cited by 27
“Following the transformation to a standard reference, EEG activity for a minimum of 15 2-second epochs of artifact-free resting EEG was averaged to calculate cross-spectra in standardized low-resolution electromagnetic tomography (sLORETA) for seven nonoverlapping frequency bands.(26) Using the sLORETA transformation…”
Dynamics of Brain Electric Field during Recall of Salpuri Dance Performance
Park, J. R., Yagyu, T., Saito, N., Kinoshita, T., & Hirai, T. (2002) · Perceptual and Motor Skills · doi:10.2466/pms.2002.95.3.955 · Cited by 17
Metadata
- Authors
- Kubicki, S., Herrmann, W. M., Fichte, K., & Freund, G.
- Venue
- Pharmacopsychiatry
- Publisher
- Georg Thieme Verlag KG
- Published
- 1979-03
- Volume
- 12
- Issue
- 02
- Pages
- 237-245
- ISSN
- 0176-3679 (ISSN-L)
- 1439-0795
- OpenAlex
- W2058741064
- Cited by
- 184
- References
- 0
- FWCI
- 0.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.