Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy
The DOI matches its Crossref record.
Abstract
BACKGROUND AND STUDY AIMS: A second-generation capsule endoscopy system, using the PillCam Colon 2, was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. The performance of this new system is reported. PATIENTS AND METHODS: In a five-center feasibility study, second-generation capsule endoscopy was prospectively compared with conventional colonoscopy as gold standard for the detection of colorectal polyps and other colonic disease, in a cohort of patients scheduled for colonoscopy and having known or suspected colonic disease. Colonoscopy was independently performed within 10 hours after capsule ingestion. Capsule-positive but colonoscopy-negative cases were counted as false-positive. RESULTS: 104 patients (mean age 49.8 years) were enrolled; data from 98 were analyzed. Patient rate for polyps of any size was 44 %, 53 % of these patients having adenomas. No adverse events related to either procedure were reported. The capsule sensitivity for the detection of patients with polyps >or= 6 mm was 89 % (95 % confidence interval [CI] 70 - 97) and for those with polyps >or= 10 mm it was 88 % (95 %CI 56 - 98), with specificities of 76 % (95 %CI 72 - 78) and 89 % (95 %CI 86 - 90), respectively. Both polyps missed by colonoscopy and mismatch in polyp size by study definition lowered specificity. Overall colon cleanliness for capsule endoscopy was adequate in 78 % of patients (95 %CI 68 - 86). CONCLUSIONS: The new second-generation colon capsule endoscopy is a safe and effective method for visualizing the colon and detecting colonic lesions. Sensitivity and specificity for detecting colorectal polyps appear to be very good, suggesting a potential for improved accuracy compared with the first-generation system. Further prospective and comparative studies are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Toward embedded detection of polyps in WCE images for early diagnosis of colorectal cancer
Silva, J., Histace, A., Romain, O., Dray, X., & Granado, B. (2014) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-013-0926-3 · Cited by 1,309
An updated Asia Pacific Consensus Recommendations on colorectal cancer screening
Sung, J. J. Y., Ng, S. C., Chan, F. K. L., Chiu, H. M., Kim, H. S., Matsuda, T., Ng, S. S. M., Lau, J. Y. W., Zheng, S., Adler, S., et al. (2015) · Gut · doi:10.1136/gutjnl-2013-306503 · Cited by 411
Self-citationClinical Practice Guidelines for the Use of Video Capsule Endoscopy
Enns, R. A., Hookey, L., Armstrong, D., Bernstein, C. N., Heitman, S. J., Teshima, C., Leontiadis, G. I., Tse, F., & Sadowski, D. (2017) · Gastroenterology · doi:10.1053/j.gastro.2016.12.032 · Cited by 400
Screening and prevention of colorectal cancer
Kanth, P., & Inadomi, J. M. (2021) · BMJ · doi:10.1136/bmj.n1855 · Cited by 358
Wang, A., Banerjee, S., Barth, B. A., Bhat, Y. M., Chauhan, S., Gottlieb, K. T., Konda, V., Maple, J. T., Murad, F., Pfau, P. R., et al. (2013) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2013.06.026 · Cited by 327
Automated Polyp Detection in Colon Capsule Endoscopy
Mamonov, A. V., Figueiredo, I. N., Figueiredo, P. N., & Richard Tsai, Y.-H. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2314959 · Cited by 292
Colon capsule endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline
Spada, C., Hassan, C., Galmiche, J., Neuhaus, H., Dumonceau, J., Adler, S., Epstein, O., Gay, G., Pennazio, M., Rex, D., et al. (2012) · Endoscopy · doi:10.1055/s-0031-1291717 · Cited by 287
Self-citationIngestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Second-generation colon capsule endoscopy compared with colonoscopy
Spada, C., Hassan, C., Munoz-Navas, M., Neuhaus, H., Deviere, J., Fockens, P., Coron, E., Gay, G., Toth, E., Riccioni, M. E., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.03.1125 · Cited by 266
Safety of cold polypectomy for < 10 mm polyps at colonoscopy: a prospective multicenter study
Repici, A., Hassan, C., Vitetta, E., Ferrara, E., Manes, G., Gullotti, G., Princiotta, A., Dulbecco, P., Gaffuri, N., Bettoni, E., et al. (2012) · Endoscopy · doi:10.1055/s-0031-1291387 · Cited by 241
S3-Leitlinie – Kolorektales Karzinom: Langversion 2.0 – November 2017–AWMF-Registernummer: 021/007OL
Schmiegel, W., Buchberger, B., Follmann, M., Graeven, U., Heinemann, V., Langer, T., Nothacker, M., Porschen, R., Rödel, C., Rösch, T., et al. (2017) · Zeitschrift für Gastroenterologie · doi:10.1055/s-0043-121106 · Cited by 241
Accuracy of Capsule Colonoscopy in Detecting Colorectal Polyps in a Screening Population
Rex, D. K., Adler, S. N., Aisenberg, J., Burch, W. C., Carretero, C., Chowers, Y., Fein, S. A., Fern, S. E., Fernandez-Urien Sainz, I., Fich, A., et al. (2015) · Gastroenterology · doi:10.1053/j.gastro.2015.01.025 · Cited by 210
Self-citationS3-Leitlinie Kolorektales Karzinom Version 1.0 - Juni 2013 AWMF-Registernummer: 021/007OL
Pox, C., Aretz, S., Bischoff, S., Graeven, U., Hass, M., Heußner, P., Hohenberger, W., Holstege, A., Hübner, J., Kolligs, F., et al. (2013) · Zeitschrift für Gastroenterologie · doi:10.1055/s-0033-1350264 · Cited by 179
Nandhra, G. K., Chaichanavichkij, P., Birch, M., & Scott, S. M. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12165272 · Cited by 26
Metadata
- Authors
- Eliakim, R., Yassin, K., Niv, Y., Metzger, Y., Lachter, J., Gal, E., Sapoznikov, B., Konikoff, F., Leichtmann, G., Fireman, Z., Kopelman, Y., & Adler, S.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2009-12-04
- Volume
- 41
- Issue
- 12
- Pages
- 1026-1031
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W1969122765
- Cited by
- 342
- References
- 0
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.