Longer mean colonoscopy withdrawal time is associated with increased adenoma detection: evidence from the Bowel Cancer Screening Programme in England
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND AND STUDY AIMS: Increasing colonoscopy withdrawal time (CWT) is thought to be associated with increasing adenoma detection rate (ADR). Current English guidelines recommend a minimum CWT of 6 minutes. It is known that in the Bowel Cancer Screening Programme (BCSP) in England there is wide variation in CWT. The aim of this observational study was to examine the relationship between CWT and ADR. PATIENTS AND METHODS: The study examined data from 31 088 colonoscopies by 147 screening program colonoscopists. Colonoscopists were grouped in four levels of mean CWT ( < 7, 7 - 8.9, 9 - 10.9, and ≥ 11 minutes). Univariable and multivariable analysis (binary logistic and negative binomial regression) were used to explore the relationship between CWT, ADR, mean number of adenomas and number of right-sided and advanced adenomas. RESULTS: In colonoscopists with a mean CWT < 7 minutes, the mean ADR was 42.5 % compared with 47.1 % in the ≥ 11-minute group (P < 0.001). The mean number of adenomas detected per procedure increased from 0.77 to 0.94, respectively (P < 0.001). The increase in adenoma detection was mainly of subcentimeter or proximal adenomas; there was no increase in the detection of advanced adenomas. Regression models showed an increase in ADR from 43 % to 46.5 % for mean CWT times ranging from 6 to 10 minutes. CONCLUSIONS: This study demonstrates that longer mean withdrawal times are associated with increasing adenoma detection, mainly of small or right-sided adenomas. However, beyond 10 minutes the increase in ADR is minimal. Mean withdrawal times longer than 6 minutes are not associated with increased detection of advanced adenomas. Withdrawal time remains an important quality metric of colonoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kaminski, M., Thomas-Gibson, S., Bugajski, M., Bretthauer, M., Rees, C., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., et al. (2017) · Endoscopy · doi:10.1055/s-0043-103411 · Cited by 885
Self-citationAn updated Asia Pacific Consensus Recommendations on colorectal cancer screening
Sung, J. J. Y., Ng, S. C., Chan, F. K. L., Chiu, H. M., Kim, H. S., Matsuda, T., Ng, S. S. M., Lau, J. Y. W., Zheng, S., Adler, S., et al. (2015) · Gut · doi:10.1136/gutjnl-2013-306503 · Cited by 411
Kaminski, M. F., Thomas‐Gibson, S., Bugajski, M., Bretthauer, M., Rees, C. J., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., et al. (2017) · United European Gastroenterology Journal · doi:10.1177/2050640617700014 · Cited by 346
Self-citationEndoscopic Improvement of the Adenoma Detection Rate during Colonoscopy - Where Do We Stand in 2015?
Floer, M., & Meister, T. (2016) · Digestion · doi:10.1159/000442464 · Cited by 300
Su, J.-R., Li, Z., Shao, X.-J., Ji, C.-R., Ji, R., Zhou, R.-C., Li, G.-C., Liu, G.-Q., He, Y.-S., Zuo, X.-L., et al. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2019.08.026 · Cited by 286
Metadata
- Authors
- Lee, T., Blanks, R., Rees, C., Wright, K., Nickerson, C., Moss, S., Chilton, A., Goddard, A., Patnick, J., McNally, R., & Rutter, M.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2012-12-19
- Volume
- 45
- Issue
- 01
- Pages
- 20-26
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2052775111
- Cited by
- 155
- References
- 0
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Longer mean colonoscopy withdrawal time is associated with increased adenoma detection: evidence from the Bowel Cancer Screening Programme in England. https://app.cochat.ai/papers/10.1055/s-0032-1325803
- The paper
- Lee, T., Blanks, R., Rees, C., Wright, K., Nickerson, C., Moss, S., Chilton, A., Goddard, A., Patnick, J., McNally, R., & Rutter, M. (2012). Longer mean colonoscopy withdrawal time is associated with increased adenoma detection: evidence from the Bowel Cancer Screening Programme in England. Endoscopy. https://doi.org/10.1055/s-0032-1325803
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.