The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Detection and Quantitative Evaluation of Lupus Circulating Anticoagulant Activity
Abstract
Summary: Sixty-six SLE patients were studied for the presence of lupus type circulating anticoagulant. Forty-nine percent of them showed activity of this anticoagulant. The sensitivity of various coagulation tests was compared. Recalcification time was found to be the most sensitive screening test and the kaolin clotting time mixture test, the best for determining the presence of the anticoagulant. Tissue thromboplastin inhibition test detected only half of the patients in whom the anticoagulant was found by recalcification time and kaolin clotting time mixture test. APTT, using 2 different reagents, resulted in 73% and 52% false negatives. A numerical index for determining the presence of the anticoagulant and its quantitative evaluation is suggested. The association between thromboembolic events, recurrent abortions and the different coagulation tests is shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boey, M. L., Colaco, C. B., Gharavi, A. E., Elkon, K. B., Loizou, S., & Hughes, G. R. (1983) · BMJ · doi:10.1136/bmj.287.6398.1021 · Cited by 508
Kelsey, P. R., Stevenson, K. J., & Poller, L. (1984) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1661166 · Cited by 91
Cited by
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197
Cause of portal or hepatic venous thrombosis in adults: The role of multiple concurrent factors
Denninger, M.-H., Chaït, Y., Casadevall, N., Hillaire, S., Guillin, M.-C., Bezeaud, A., Erlinger, S., Briere, J., & Valla, D. (2000) · Hepatology · doi:10.1002/hep.510310307 · Cited by 686
Condat, B., Pessione, F., Denninger, M. H., Hillaire, S., & Valla, D. (2000) · Hepatology · doi:10.1053/jhep.2000.16597 · Cited by 492
Immunology and clinical importance of antiphospholipid antibodies
McNeil, H. P., Chesterman, C. N., & Krilis, S. A. (1991) · Advances in immunology · doi:10.1016/s0065-2776(08)60777-4 · Cited by 481
Hillaire, S., Bonte, E., Denninger, M.-H., Casadevall, N., Cadranel, J.-F., Lebrec, D., Valla, D., & Degott, C. (2002) · Gut · doi:10.1136/gut.51.2.275 · Cited by 310
Metadata
- Authors
- Rosner, E., Pauzner, R., Lusky, A., Modan, M., & Many, A.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1987
- Volume
- 57
- Issue
- 02
- Pages
- 144-147
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2399915947
- Cited by
- 188
- References
- 2
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and Quantitative Evaluation of Lupus Circulating Anticoagulant Activity. https://app.cochat.ai/papers/10.1055/s-0038-1651083
- The paper
- Rosner, E., Pauzner, R., Lusky, A., Modan, M., & Many, A. (1987). Detection and Quantitative Evaluation of Lupus Circulating Anticoagulant Activity. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1651083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.