CoChat

Multicenter Evaluation of Nine Commercial Kits for the Quantitation of Anticardiolipin Antibodies

Reber, G, Arvieux, J, Comby, E, Degenne, D, de Moerloose, P, Sanmarco, M, Potron, G, On behalf of the working group on Methodologies in Haemostasis from the GEHT (Groupe d’Etudes sur I’Hémostase et la Thrombose), France · 1995 · Thrombosis and Haemostasis
Cited by 120

The DOI matches its Crossref record.

Abstract

Summary: The performances of nine commercial kits and an in-house method (HM) for the quantitation of anticardiolipin antibodies (ACA) have been evaluated in a multicenter study. Ninety control and patient samples and six standards from Louisville University were run with kits and with the HM. Marked differences in positivity rate between kits were observed, ranging from 31 to 60% for IgG and 6 to 50% for IgM. Concordance between kits occurred in 59 and 51% of samples for IgG and IgM respectively. Concordance coefficients (kappa) ranged from 0.13 to 0.92. Slopes of regression lines between the declared units of Louisville standards and the units measured from the calibrators of the kits showed great diversity and ranged from 0.159 to 0.931 for IgG and from 0.236 to 0.836 for IgM. The β2-glycoprotein I (β2-GPI) content of the dilution buffers and the wells supplied with the kits revealed noticeable differences. However samples containing anti-(β2-GPI antibodies were classified similarly by all but one kit. In contrast the ability to measure samples devoid of anti-β2-GPI antibodies differed markedly between the kits. This study shows that differences in positivity rates between the commercial kits may contribute to the differences in ACA prevalence rate found in the literature. The choice of cut-off levels may partly explain the moderate concordance between the kits. In addition some samples behave very differently depending on the kits. In spite of the expression of results in PL units, standardization of ACA assays has not been achieved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0038-1653795

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 120

Metadata

Authors
Reber, G., Arvieux, J., Comby, E., Degenne, D., de Moerloose, P., Sanmarco, M., Potron, G., & On behalf of the working group on Methodologies in Haemostasis from the GEHT (Groupe d’Etudes sur I’Hémostase et la Thrombose), F.
Venue
Thrombosis and Haemostasis
Published
1995
Volume
73
Issue
03
Pages
444-452
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W4323283585
Cited by
120
References
0
FWCI
6.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multicenter Evaluation of Nine Commercial Kits for the Quantitation of Anticardiolipin Antibodies. https://app.cochat.ai/papers/10.1055/s-0038-1653795
The paper
Reber, G., Arvieux, J., Comby, E., Degenne, D., de Moerloose, P., Sanmarco, M., Potron, G., & On behalf of the working group on Methodologies in Haemostasis from the GEHT (Groupe d’Etudes sur I’Hémostase et la Thrombose), F. (1995). Multicenter Evaluation of Nine Commercial Kits for the Quantitation of Anticardiolipin Antibodies. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1653795

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.