Ventilatory Thresholds Assessment from Heart Rate Variability during an Incremental Exhaustive Running Test
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The present study examined whether the ventilatory thresholds during an incremental exhaustive running test could be determined using heart rate variability (HRV) analysis. Beat-to-beat RR interval, V(.-)O (2), V(.-)CO (2) and V(.-) (E) of twelve professional soccer players were collected during an incremental test performed on a track until exhaustion. The "smoothed pseudo Wigner-Ville distribution" (SPWVD) time-frequency analysis method was applied to the RR time series to compute the usual HRV components vs. running speed stages. The ventilatory equivalent method was used to assess the ventilatory thresholds (VT1 and VT2) from respiratory components. In addition, ventilatory thresholds were assessed from the instantaneous components of respiratory sinus arrhythmia (RSA) by two different methods: 1) from the high frequency peak of HRV ( FHF), and 2) from the product of the spectral power contained within the high frequency band (0.15 Hz to fmax) by FHF (HF x FHF) giving two thresholds: HFT1 and HFT2. Since the relationship between FHF and running speed was linear for all subjects, the VTs could not be determined from FHF. No significant differences were found between respective running speeds at VT1 vs. HFT1 (9.83 +/- 1.12 vs. 10.08 +/- 1.29 km x h (-1), n.s.) nor between the respective running speeds at VT2 vs. HFT2 (12.55 +/- 1.31 vs. 12.58 +/- 1.33 km x h (-1), n.s.). Linear regression analysis showed a strong correlation between VT1 vs. HFT1 (R (2) = 0.94, p < 0.001) and VT2 vs. HFT2 (R (2) = 0.96, p < 0.001). The Bland-Altman plot analysis reveals that the assessment from RSA gives an accurate estimation of the VTs, with HF x FHF providing a reliable index for the ventilatory thresholds detection. This study has shown that VTs could be assessed during an incremental running test performed on a track using a simple beat-to-beat heart rate monitor, which is less expensive and complex than the classical respiratory measurement devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Durnin, J. V. G. A., & Womersley, J. (1974) · British Journal of Nutrition · doi:10.1079/bjn19740060 · Cited by 6,343
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
An evaluation of the predictive validity and reliability of ventilatory threshold
AMANN, M., SUBUDHI, A. W., WALKER, J., EISENMAN, P., SHULTZ, B., & FOSTER, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000142305.18543.34 · Cited by 90
Cited by
Michael, S., Graham, K. S., & Davis, G. M. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00301 · Cited by 603
Validity and Reliability of Short-Term Heart-Rate Variability from the Polar S810
NUNAN, D., DONOVAN, G., JAKOVLJEVIC, D. G., HODGES, L. D., SANDERCOCK, G. R. H., & BRODIE, D. A. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318184a4b1 · Cited by 302
“The popularity of this new method is illustrated by several studies that have made use of the Polar S810 for assessment of short-term HRV under a variety of situations (3,8,9,11,17,36).”
MethodLin, C.-W., Huang, C.-F., Wang, J.-S., Fu, L.-L., & Mao, T.-Y. (2020) · Saudi Journal of Biological Sciences · doi:10.1016/j.sjbs.2020.03.005 · Cited by 20
“, 1982), and heart rate variability (Cottin et al., 2007).”
Contreras-Briceño, F., Espinosa-Ramirez, M., Keim-Bagnara, V., Carreño-Román, M., Rodríguez-Villagra, R., Villegas-Belmar, F., Viscor, G., Gabrielli, L., Andía, M. E., Araneda, O. F., et al. (2022) · Life · doi:10.3390/life12030444 · Cited by 17
“…as the v-slope method, based on the breakpoint of the linearity of the curve V̇ CO 2 vs V̇ O 2 [24,44,45], breakpoint at heart-rate variability [46–50], or lactate blood level curves [11,41,51]; however, in order to diminish the variability inter-and intra-evaluator, we chose the method widely…”
Metadata
- Authors
- Cottin, F., Médigue, C., Lopes, P., Leprêtre, P.-M., Heubert, R., & Billat, V.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2007-04
- Volume
- 28
- Issue
- 4
- Pages
- 287-294
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2124317955
- Cited by
- 125
- References
- 4
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.