The present study examined whether the ventilatory thresholds during an incremental exhaustive running test could be determined using heart rate variability (HRV) analysis. Beat-to-beat RR interval, V(.-)O (2), V(.-)CO (2) and V(.-) (E) of twelve professional soccer players were collected during an incremental test performed on a track until exhaustion. The "smoothed pseudo Wigner-Ville distribution" (SPWVD) time-frequency analysis method was applied to the RR time series to compute the usual HRV components vs. running speed stages. The ventilatory equivalent method was used to assess the ventilatory thresholds (VT1 and VT2) from respiratory components. In addition, ventilatory thresholds were assessed from the instantaneous components of respiratory sinus arrhythmia (RSA) by two different methods: 1) from the high frequency peak of HRV ( FHF), and 2) from the product of the spectral power contained within the high frequency band (0.15 Hz to fmax) by FHF (HF x FHF) giving two thresholds: HFT1 and HFT2. Since the relationship between FHF and running speed was linear for all subjects, the VTs could not be determined from FHF. No significant differences were found between respective running speeds at VT1 vs. HFT1 (9.83 +/- 1.12 vs. 10.08 +/- 1.29 km x h (-1), n.s.) nor between the respective running speeds at VT2 vs. HFT2 (12.55 +/- 1.31 vs. 12.58 +/- 1.33 km x h (-1), n.s.). Linear regression analysis showed a strong correlation between VT1 vs. HFT1 (R (2) = 0.94, p < 0.001) and VT2 vs. HFT2 (R (2) = 0.96, p < 0.001). The Bland-Altman plot analysis reveals that the assessment from RSA gives an accurate estimation of the VTs, with HF x FHF providing a reliable index for the ventilatory thresholds detection. This study has shown that VTs could be assessed during an incremental running test performed on a track using a simple beat-to-beat heart rate monitor, which is less expensive and complex than the classical respiratory measurement devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2006-924355

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Cottin, F., Médigue, C., Lopes, P., Leprêtre, P.-M., Heubert, R., & Billat, V.
Venue
International Journal of Sports Medicine
Published
2007-04
Volume
28
Issue
4
Pages
287-294
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W2124317955
Cited by
125
References
4
FWCI
5.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.