Selektive Nerventransfers zur verbesserten Steuerung myoelektrischer Armprothesen
The DOI matches its Crossref record.
Abstract
To date, the movement of myoelectrical arm prostheses proceeds via two transcutaneous electrodes that are controlled by two separately innervated muscle groups. The various control levels are chosen by co-contractions of these muscles and the respective level is linearly controlled by the same muscles. A harmonious course of movement as in the corresponding natural pattern of motion is not possible in this way. An appreciable improvement would be given by the control of the individual movement levels by signals that correspond neuronally with the natural pattern of motion. Just recently, prostheses with six control levels have been realised technically. The objective is to separate the major arm nerves, such as the musculocutaneous nerve, radial nerve, median nerve and ulnar nerve, from the proximal arm nerve plexus and to transfer them to the residual nerve branches of muscles near the stem in order to create meaningful neuromuscular units that can serve as impulse sources for myoelectrical prosthesis. As target muscles, above all, one can consider the major/minor pectoral muscles or, respectively, the latissimus muscle. According to the activity of the donor nerves, these muscles would contract and control the prosthesis via transcutaneous electrode. In this way, a harmonious control corresponding intuitively to the natural pattern of movement would be possible without the necessity for the patient to continuously switch between the various control levels. Prerequisites for this are intact proximal muscle groups and a more or less intact arm nerve plexus with the possibility to isolate donor nerves according to the topographic-anatomic situation. For this reason, a preoperative MRI examination, a high resolution sonographic study and balancing NLG and EMG of the residual nerve plexus are necessary. For the preoperative planning phase as well as for the postoperative follow-up, a detailed procedure has been established, in cooperation with the innovation department of the Otto Bock company, to create the most meaningful switch levels, to optimise electrode placement as well as to clarify prosthesis incorporation. Finally, a complex rehabilitation programme is necessary for the patient to achieve an optimal result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationJaramillo-Yánez, A., Benalcázar, M. E., & Mena-Maldonado, E. (2020) · Sensors · doi:10.3390/s20092467 · Cited by 259
Aszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61776-1 · Cited by 152
Self-citationSalminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
“Despite the limitations of surface EMG as source of control signals, the increased number of EMG sites achieved by TMR surgery using selective nerve transfers enables prosthetic control in a more intuitive manner than with naturally innervated muscles alone (11).”
BackgroundSelf-citationInnovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71
Metadata
- Authors
- Aszmann, O., Dietl, H., & Frey, M.
- Venue
- Handchirurgie · Mikrochirurgie · Plastische Chirurgie
- Publisher
- Georg Thieme Verlag KG
- Published
- 2008-02
- Volume
- 40
- Issue
- 1
- Pages
- 60-65
- ISSN
- 0722-1819 (ISSN-L)
- 1439-3980
- OpenAlex
- W14466366
- Cited by
- 49
- References
- 0
- FWCI
- 0.85
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selektive Nerventransfers zur verbesserten Steuerung myoelektrischer Armprothesen. https://app.cochat.ai/papers/10.1055/s-2007-989415
- The paper
- Aszmann, O., Dietl, H., & Frey, M. (2008). Selektive Nerventransfers zur verbesserten Steuerung myoelektrischer Armprothesen. Handchirurgie · Mikrochirurgie · Plastische Chirurgie. https://doi.org/10.1055/s-2007-989415
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.