The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.
Innovations in Prosthetic Interfaces for the Upper Extremity
Abstract
Advancements in modern robotic technology have led to the development of highly sophisticated upper extremity prosthetic limbs. High-fidelity volitional control of these devices is dependent on the critical interface between the patient and the mechanical prosthesis. Recent innovations in prosthetic interfaces have focused on several control strategies. Targeted muscle reinnervation is currently the most immediately applicable prosthetic control strategy and is particularly indicated in proximal upper extremity amputations. Investigation into various brain interfaces has allowed acquisition of neuroelectric signals directly or indirectly from the central nervous system for prosthetic control. Peripheral nerve interfaces permit signal transduction from both motor and sensory nerves with a higher degree of selectivity. This article reviews the current developments in each of these interface systems and discusses the potential of these approaches to facilitate motor control and sensory feedback in upper extremity neuroprosthetic devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, current peripheral nerve interfaces have limitations, which minimize their clinical utility (1, 2).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [1]
In the citing paper
“With this technique, the prosthetic control is more natural compared to conventional myoelectric methods, and the patients are more efficient in performing tasks [39].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [39]
In the citing paper
“This can help the transmission of sensory feedback and the attainment of electromyographic (EMG) signals by surface electrodes from the reinnervated site to control the prosthetic limb (Kung et al., 2013; Cheesborough et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Kung et al., 2013
Citations
Cites
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Research works printed but not linked: 5
- Freeland, 2007, Orthopedics, 30, 120, 10.3928/01477447-20070201-16 · doi:10.3928/01477447-20070201-16
- Tenore, 2011, Johns Hopkins APL Tech Dig, 30, 230
- Kipke, 2004, Conf Proc IEEE Eng Med Biol Soc, 7, 5344
- Slot, 1997, Artif Organs, 21, 207
- Park, 2009, Conf Proc IEEE Eng Med Biol Soc, 2009, 6789
Cited by
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Self-citationWoo, S. L., Kung, T. A., Brown, D. L., Leonard, J. A., Kelly, B. M., & Cederna, P. S. (2016) · Plastic and Reconstructive Surgery - Global Open · doi:10.1097/gox.0000000000001038 · Cited by 230
Self-citationThe Billion Cell Construct: Will Three-Dimensional Printing Get Us There?
Miller, J. S. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001882 · Cited by 199
“This conceptual framework has proven useful in practice, with contemporary work applied to human patients through surgical implants such as knee, hip, and limb prostheses [2]; pacemakers; and cochlear and retinal devices [3].”
MethodKung, T. A., Langhals, N. B., Martin, D. C., Johnson, P. J., Cederna, P. S., & Urbanchek, M. G. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000168 · Cited by 181
Self-citation
Metadata
- Authors
- Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S.
- Affiliations
- University of Michigan (US)
- Michigan Medicine (US)
- SIU Medicine (US)
- Southern Illinois University Carbondale (US)
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2013-12
- Volume
- 132
- Issue
- 6
- Pages
- 1515-1523
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2028659107
- Cited by
- 71
- References
- 74
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 10 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 4 · 2018: 4 · 2017: 5 · 2016: 8 · 2015: 4 · 2014: 9
- FWCI
- 0.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Plastic & Reconstructive Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- upper limb prosthesis, targeted muscle reinnervation, brain-computer interface, peripheral nerve interfaces, neuroprosthetics, sensory feedback, upper limb amputation, motor control
- MeSH terms
- Afferent Pathways, Amputation, Surgical, Arm, Artificial Limbs, Efferent Pathways, Humans, Robotics, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Innovations in Prosthetic Interfaces for the Upper Extremity. https://app.cochat.ai/papers/10.1097/prs.0b013e3182a97e5f
- The paper
- Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013). Innovations in Prosthetic Interfaces for the Upper Extremity. Plastic and Reconstructive Surgery. https://doi.org/10.1097/prs.0b013e3182a97e5f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.