Continuous Positive-Pressure Ventilation in Acute Respiratory Failure: Effects on Hemodynamics and Lung Function
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Abstract Continuous positive-pressure ventilation was used in eight patients with severe acute respiratory failure. Cardiac output and lung function were studied during continuous positive-pressure ventilation (mean end-expiratory pressure, 13 cm of water) and a 30-minute interval of intermittent positive-pressure ventilation. Although the mean cardiac index rose from 3.6 to 4.5 liters per minute per square meter of body-surface area, the mean intrapulmonary shunt increased by 9 per cent with changeover to intermittent positive-pressure ventilation. Satisfactory oxygenation was maintained in all patients during continuous positive-pressure ventilation with 50 per cent inspired oxygen or less. With intermittent positive-pressure ventilation arterial oxygen tension promptly fell by 161 mm of mercury, 79 per cent occurring within one minute. Prevention of air-space collapse during expiration and an increase in functional residual capacity probably explain improved oxygenation with continuous positive-pressur...
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cournand, A. F., Motley, H. L., Werkö, L., & Richards, D. W. (1947) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1947.152.1.162 · Cited by 780
Pulmonary Lesions Associated with Oxygen Therapy and Artificial Ventilation
Nash, G., Blennerhassett, J. B., & Pontoppidan, H. (1967) · New England Journal of Medicine · doi:10.1056/nejm196702162760702 · Cited by 547
Self-citationPontoppidan, H., Hedley‐Whyte, J., BENDIXEN, H. H., Laver, M. B., & Radford, E. P. (1965) · New England Journal of Medicine · doi:10.1056/nejm196508192730801 · Cited by 98
Self-citationHedley‐Whyte, J., Pontoppidan, H., & Morris, M. J. (1966) · Journal of Clinical Investigation · doi:10.1172/jci105461 · Cited by 71
Self-citation
Cited by
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure
Suter, P. M., Fairley, H. B., & Isenberg, M. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197502062920604 · Cited by 1,295
Lung Stress and Strain during Mechanical Ventilation for Acute Respiratory Distress Syndrome
Chiumello, D., Carlesso, E., Cadringher, P., Caironi, P., Valenza, F., Polli, F., Tallarini, F., Cozzi, P., Cressoni, M., Colombo, A., et al. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200710-1589oc · Cited by 777
Acute Respiratory Failure in the Adult: (First of Three Parts)
Pontoppidan, H., Geffin, B., & Lowenstein, E. (1972) · New England Journal of Medicine · doi:10.1056/nejm197210052871404 · Cited by 439
Self-citationVentilation with end-expiratory pressure in acute lung disease
Falke, K. J., Pontoppidan, H., Kumar, A., Leith, D. E., Geffin, B., & Laver, M. B. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107042 · Cited by 435
Self-citationHigh Level Positive End Expiratory Pressure (PEEP) in Acute Respiratory Insufficiency
Kirby, R. R., Downs, J. B., Civetta, J. M., Modell, J. H., Dannemiller, F. J., Klein, E. F., & Hodges, M. (1975) · Chest · doi:10.1378/chest.67.2.156 · Cited by 317
Cyclic changes in right ventricular output impedance during mechanical ventilation
Vieillard-Baron, A., Loubieres, Y., Schmitt, J.-M., Page, B., Dubourg, O., & Jardin, F. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1644 · Cited by 303
Ranieri, V. M., Eissa, N. T., Corbeil, C., Chassé, M., Braidy, J., Matar, N., & Milic-Emili, J. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.3_pt_1.544 · Cited by 293
Lewandowski, K., Rossaint, R., Pappert, D., Gerlach, H., Slama, K.-J., Weidemann, H., Frey, D. J. M., Hoffmann, O., Keske, U., & Falke, K. J. (1997) · Intensive Care Medicine · doi:10.1007/s001340050418 · Cited by 287
Self-citationKrafft, P., Fridrich, P., Pernerstorfer, T., Fitzgerald, R. D., Koc, D., Schneider, B., Hammerle, A. F., & Steltzer, H. (1996) · Intensive Care Medicine · doi:10.1007/bf01708091 · Cited by 244
Acute lung injury and the acute respiratory distress syndrome
Luce, J. M. (1998) · Critical Care Medicine · doi:10.1097/00003246-199802000-00043 · Cited by 180
Robin, E. D., Cross, C. E., & Zelis, R. (1973) · New England Journal of Medicine · doi:10.1056/nejm197302082880606 · Cited by 172
Metadata
- Authors
- Kumar, A., Falke, K. J., Geffin, B., Aldredge, C. F., Laver, M. B., Lowenstein, E., & Pontoppidan, H.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1970-12-24
- Volume
- 283
- Issue
- 26
- Pages
- 1430-1436
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2337197452
- Cited by
- 402
- References
- 4
- FWCI
- 58.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.