Abstract

In a context such as acute respiratory distress syndrome, where optimum tidal volume and airway pressure levels are debated, the present study was designed to differentiate the right ventricular (RV) consequences of increasing lung volume from those secondary to increasing airway pressure during tidal ventilation. The study was conducted by combined two-dimensional echocardiographic and Doppler studies in 10 patients requiring mechanical ventilation in the controlled mode because of acute respiratory failure. Continuous monitoring of airway pressure on echocardiographic and Doppler recordings provided accurate timing of each cardiac event during the respiratory cycle, with particular attention being paid to end-expiratory and end-inspiratory atrial diameters, RV dimensions, and pulmonary artery and tricuspid flow estimated by the velocity-time integral (PA VTI and T VTI, respectively). At baseline, lung inflation during the inspiratory phase of mechanical ventilation produced a drop in PA VTI from 14.3 ± 2.6 cm at end expiration to 11.3 ± 2.1 cm at end inspiration. This drop occurred without reduction in right atrial diameter or in RV diastolic dimensions. It was not preceded but was followed by a decrease in T VTI, thus confirming an increase in RV outflow impedance. Manipulation of tidal volume without changing airway pressure and manipulation of airway pressure without changing tidal volume demonstrated that tidal volume, but not airway pressure, was the main determinant factor of RV afterloading during mechanical ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1999.87.5.1644

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 303

Metadata

Authors
Vieillard-Baron, A., Loubieres, Y., Schmitt, J.-M., Page, B., Dubourg, O., & Jardin, F.
Venue
Journal of Applied Physiology
Published
1999-11-01
Volume
87
Issue
5
Pages
1644-1650
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1938976069
Cited by
303
References
14
FWCI
1.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cyclic changes in right ventricular output impedance during mechanical ventilation. https://app.cochat.ai/papers/10.1152/jappl.1999.87.5.1644
The paper
Vieillard-Baron, A., Loubieres, Y., Schmitt, J.-M., Page, B., Dubourg, O., & Jardin, F. (1999). Cyclic changes in right ventricular output impedance during mechanical ventilation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1999.87.5.1644

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.