The Declining Specificity of Exercise Radionuclide Ventriculography
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Although exercise radionuclide ventriculography was initially reported to be a highly specific test for coronary-artery disease, later studies reported a high false-positive rate. To verify this turnabout, we analyzed the responses in 77 angiographically normal patients; 32 were studied from 1978 to 1979 (the early period), and 45 from 1980 to 1982 (the recent period). Most patients studied in the early period had normal responses (94 per cent for ejection fraction and 84 per cent for wall motion). In contrast, normal responses were less frequent in patients studied in the recent period (49 per cent for ejection fraction and 36 per cent for wall motion, P less than 0.001). The probability of coronary disease before testing was higher in these patients (38 vs. 7 per cent, P less than 0.001). More patients studied in the recent period underwent radionuclide ventriculography before angiography (78 vs. 22 per cent, P less than 0.001), and more of these prior studies had abnormal results than those performed after angiography (55 vs. 6 per cent, P less than 0.0001). Thus, two factors are responsible for the temporal decline in specificity: a change in the population being tested (pretest referral bias) and a preferential selection of patients with a positive test response for coronary angiography (post-test referral bias).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Borer, J. S., Bacharach, S. L., Green, M. V., Kent, K. M., Epstein, S. E., Johnston, G. S., & Mack, B. (1977) · New England Journal of Medicine · doi:10.1056/nejm197704142961503 · Cited by 773
ARNETT, E. N., ISNER, J. M., REDWOOD, D. R., KENT, K. M., BAKER, W. P., ACKERSTEIN, H., & ROBERTS, W. C. (1979) · Annals of Internal Medicine · doi:10.7326/0003-4819-91-3-350 · Cited by 628
Opherk, D., Zebe, H., Weihe, E., Mall, G., Dürr, C., Gravert, B., Mehmel, H. C., Schwarz, F., & Kübler, W. (1981) · Circulation · doi:10.1161/01.cir.63.4.817 · Cited by 440
Correlation of the Antemortem Coronary Arteriogram and the Postmortem Specimen
VLODAVER, Z., FRECH, R., VAN TASSEL, R. A., & EDWARDS, J. E. (1973) · Circulation · doi:10.1161/01.cir.47.1.162 · Cited by 395
Effect of Age on the Response of the Left Ventricular Ejection Fraction to Exercise
Port, S., Cobb, F. R., Coleman, R. E., & Jones, R. H. (1980) · New England Journal of Medicine · doi:10.1056/nejm198011133032001 · Cited by 353
Diamond, G. A., Staniloff, H. M., Forrester, J. S., Pollock, B. H., & Swan, H. J. C. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80072-2 · Cited by 276
Self-citationDiamond, G. A., Forrester, J. S., Hirsch, M., Staniloff, H. M., Vas, R., Berman, D. S., & Swan, H. J. (1980) · Journal of Clinical Investigation · doi:10.1172/jci109776 · Cited by 241
Self-citationGlobal and regional left ventricular response to bicycle exercise in coronary artery disease
Berger, H. J., Reduto, L. A., Johnstone, D. E., Borkowski, H., Sands, J. M., Cohen, L. S., Langou, R. A., Gottschalk, A., & Zaret, B. L. (1979) · The American Journal of Medicine · doi:10.1016/0002-9343(79)90476-5 · Cited by 216
Rozanski, A., Berman, D., Gray, R., Diamond, G., Raymond, M., Prause, J., Maddahi, J., Swan, H. J. C., & Matloff, J. (1982) · New England Journal of Medicine · doi:10.1056/nejm198207223070402 · Cited by 161
Self-citationDiagnostic accuracy of cardiologists compared with probability calculations using Bayes' rule
Hlatky, M. A., Botvinick, E. H., & Brundage, B. H. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90211-9 · Cited by 75
STEELE, P. P., Rainwater, J. O., Jensen, D. P., Vogel, R. A., & Battock, D. J. (1978) · CHEST Journal · doi:10.1378/chest.74.5.526 · Cited by 19
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Exercise-induced ST depression in the diagnosis of coronary artery disease. A meta-analysis.
Gianrossi, R., Detrano, R., Mulvihill, D., Lehmann, K., Dubach, P., Colombo, A., McArthur, D., & Froelicher, V (1989) · Circulation · doi:10.1161/01.cir.80.1.87 · Cited by 846
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Metadata
- Authors
- Rozanski, A., Diamond, G. A., Berman, D., Forrester, J. S., Morris, D., & Swan, H. J. C.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1983-09
- Volume
- 309
- Issue
- 9
- Pages
- 518-522
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2088724740
- Cited by
- 316
- References
- 12
- FWCI
- 20.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.