The Declining Specificity of Exercise Radionuclide Ventriculography
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Although exercise radionuclide ventriculography was initially reported to be a highly specific test for coronary-artery disease, later studies reported a high false-positive rate. To verify this turnabout, we analyzed the responses in 77 angiographically normal patients; 32 were studied from 1978 to 1979 (the early period), and 45 from 1980 to 1982 (the recent period). Most patients studied in the early period had normal responses (94 per cent for ejection fraction and 84 per cent for wall motion). In contrast, normal responses were less frequent in patients studied in the recent period (49 per cent for ejection fraction and 36 per cent for wall motion, P less than 0.001). The probability of coronary disease before testing was higher in these patients (38 vs. 7 per cent, P less than 0.001). More patients studied in the recent period underwent radionuclide ventriculography before angiography (78 vs. 22 per cent, P less than 0.001), and more of these prior studies had abnormal results than those performed after angiography (55 vs. 6 per cent, P less than 0.0001). Thus, two factors are responsible for the temporal decline in specificity: a change in the population being tested (pretest referral bias) and a preferential selection of patients with a positive test response for coronary angiography (post-test referral bias).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Borer, J. S., Bacharach, S. L., Green, M. V., Kent, K. M., Epstein, S. E., Johnston, G. S., & Mack, B. (1977) · New England Journal of Medicine · doi:10.1056/nejm197704142961503 · Cited by 773
ARNETT, E. N., ISNER, J. M., REDWOOD, D. R., KENT, K. M., BAKER, W. P., ACKERSTEIN, H., & ROBERTS, W. C. (1979) · Annals of Internal Medicine · doi:10.7326/0003-4819-91-3-350 · Cited by 628
Opherk, D., Zebe, H., Weihe, E., Mall, G., Dürr, C., Gravert, B., Mehmel, H. C., Schwarz, F., & Kübler, W. (1981) · Circulation · doi:10.1161/01.cir.63.4.817 · Cited by 440
Correlation of the Antemortem Coronary Arteriogram and the Postmortem Specimen
VLODAVER, Z., FRECH, R., VAN TASSEL, R. A., & EDWARDS, J. E. (1973) · Circulation · doi:10.1161/01.cir.47.1.162 · Cited by 395
Effect of Age on the Response of the Left Ventricular Ejection Fraction to Exercise
Port, S., Cobb, F. R., Coleman, R. E., & Jones, R. H. (1980) · New England Journal of Medicine · doi:10.1056/nejm198011133032001 · Cited by 353
Diamond, G. A., Staniloff, H. M., Forrester, J. S., Pollock, B. H., & Swan, H. J. C. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80072-2 · Cited by 276
Self-citationDiamond, G. A., Forrester, J. S., Hirsch, M., Staniloff, H. M., Vas, R., Berman, D. S., & Swan, H. J. (1980) · Journal of Clinical Investigation · doi:10.1172/jci109776 · Cited by 241
Self-citationGlobal and regional left ventricular response to bicycle exercise in coronary artery disease
Berger, H. J., Reduto, L. A., Johnstone, D. E., Borkowski, H., Sands, J. M., Cohen, L. S., Langou, R. A., Gottschalk, A., & Zaret, B. L. (1979) · The American Journal of Medicine · doi:10.1016/0002-9343(79)90476-5 · Cited by 216
Rozanski, A., Berman, D., Gray, R., Diamond, G., Raymond, M., Prause, J., Maddahi, J., Swan, H. J. C., & Matloff, J. (1982) · New England Journal of Medicine · doi:10.1056/nejm198207223070402 · Cited by 161
Self-citation
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Exercise-induced ST depression in the diagnosis of coronary artery disease. A meta-analysis.
Gianrossi, R., Detrano, R., Mulvihill, D., Lehmann, K., Dubach, P., Colombo, A., McArthur, D., & Froelicher, V (1989) · Circulation · doi:10.1161/01.cir.80.1.87 · Cited by 846
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Gibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Berman, D. S., Kiat, H., Friedman, J. D., Wang, F. P., Van Train, K., Matzer, L., Maddahi, J., & Germano, G. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90557-h · Cited by 528
Self-citationBiases in the assessment of diagnostic tests
Begg, C. B. (1987) · Statistics in Medicine · doi:10.1002/sim.4780060402 · Cited by 496
Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance
Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S. (1998) · JAMA · doi:10.1001/jama.280.10.913 · Cited by 490
Sex Bias in Considering Coronary Bypass Surgery
TOBIN, J. N., WASSERTHEIL-SMOLLER, S., WEXLER, J. P., STEINGART, R. M., BUDNER, N., LENSE, L., & WACHSPRESS, J. (1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-107-1-19 · Cited by 481
Underwood, S. R., Anagnostopoulos, C., Cerqueira, M., Ell, P. J., Flint, E. J., Harbinson, M., Kelion, A. D., Al-Mohammad, A., Prvulovich, E. M., Shaw, L. J., et al. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1344-5 · Cited by 481
Mieres, J. H., Shaw, L. J., Arai, A., Budoff, M. J., Flamm, S. D., Hundley, W. G., Marwick, T. H., Mosca, L., Patel, A. R., Quinones, M. A., et al. (2005) · Circulation · doi:10.1161/01.cir.0000155233.67287.60 · Cited by 469
Berman, D. S., Wong, N. D., Gransar, H., Miranda-Peats, R., Dahlbeck, J., Hayes, S. W., Friedman, J. D., Kang, X., Polk, D., Hachamovitch, R., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.06.042 · Cited by 437
Self-citationKlem, I., Heitner, J. F., Shah, D. J., Sketch, M. H., Behar, V., Weinsaft, J., Cawley, P., Parker, M., Elliott, M., Judd, R. M., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.074 · Cited by 415
Assessing the quality of research.
Glasziou, P., Vandenbroucke, J., & Chalmers, I. (2004) · BMJ · doi:10.1136/bmj.328.7430.39 · Cited by 391
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J. (2004) · Health Technology Assessment · doi:10.3310/hta8250 · Cited by 372
SOX, H. C. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-104-1-60 · Cited by 364
Kiat, H., Maddahi, J., Roy, L. T., Van Train, K., Friedman, J., Resser, K., & Berman, D. S. (1989) · American Heart Journal · doi:10.1016/0002-8703(89)90649-2 · Cited by 308
Self-citationPrognostic Significance of Dyspnea in Patients Referred for Cardiac Stress Testing
Abidov, A., Rozanski, A., Hachamovitch, R., Hayes, S. W., Aboul-Enein, F., Cohen, I., Friedman, J. D., Germano, G., & Berman, D. S. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042741 · Cited by 297
Self-citationA systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Sampson, U. K., Dorbala, S., Limaye, A., Kwong, R., & Di Carli, M. F. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.015 · Cited by 277
Mazzanti, M., Germano, G., Kiat, H., Kavanagh, P. B., Alexanderson, E., Friedman, J. D., Hachamovitch, R., Van Train, K. F., & Berman, D. S. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00052-6 · Cited by 266
Self-citationIrwig, L. (2002) · BMJ · doi:10.1136/bmj.324.7338.669 · Cited by 246
Mangano, D. T., London, M. J., Tubau, J. F., Browner, W. S., Hollenberg, M., Krupski, W., Layug, E. L., & Massie, B. (1991) · Circulation · doi:10.1161/01.cir.84.2.493 · Cited by 240
Legrand, V., Hodgson, J. M., Bates, E. R., Aueron, F. M., Mancini, G. B. J., Smith, J. S., Gross, M. D., & Vogel, R. A. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80209-6 · Cited by 209
The diagnostic accuracy of the exercise electrocardiogram: A meta-analysis of 22 years of research
Detrano, R., Gianrossi, R., & Froelicher, V. (1989) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(89)90025-x · Cited by 199
Maddahi, J., van Train, K., Prigent, F., Garcia, E. V., Friedman, J., Ostrzega, E., & Berman, D. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90017-x · Cited by 195
Self-citationSex and Test Verification Bias: Impact on the Diagnostic Value of Exercise Echocardiography
Roger, V. L., Pellikka, P. A., Bell, M. R., Chow, C. W. H., Bailey, K. R., & Seward, J. B. (1997) · Circulation · doi:10.1161/01.cir.95.2.405 · Cited by 194
Moons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Heart rate adjustment of ST segment depression for improved detection of coronary artery disease.
Kligfield, P., Ameisen, O., & Okin, P. M. (1989) · Circulation · doi:10.1161/01.cir.79.2.245 · Cited by 174
Zaret, B. L., Rigo, P., Wackers, F. J. T., Hendel, R. C., Braat, S. H., Iskandrian, A. S., Sridhara, B. S., Jain, D., Itti, R., Serafini, A. N., et al. (1995) · Circulation · doi:10.1161/01.cir.91.2.313 · Cited by 174
Intermediate, Indeterminate, and Uninterpretable Diagnostic Test Results
Simel, D. L., Feussner, J. R., Delong, E. R., & Matchar, D. B. (1987) · Medical Decision Making · doi:10.1177/0272989x8700700208 · Cited by 159
The Dot Plot: A Starting Point for Evaluating Test Performance
Krieg, A. F. (1988) · JAMA · doi:10.1001/jama.1988.03410220093035 · Cited by 18
Metadata
- Authors
- Rozanski, A., Diamond, G. A., Berman, D., Forrester, J. S., Morris, D., & Swan, H. J. C.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1983-09
- Volume
- 309
- Issue
- 9
- Pages
- 518-522
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2088724740
- Cited by
- 316
- References
- 12
- FWCI
- 20.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.