CoChat

The Effect of Varying Levels of Outdoor-Air Supply on the Symptoms of Sick Building Syndrome

Open access
Menzies, Richard, Tamblyn, Robyn, Farant, Jean-Pierre, Hanley, James, Nunes, Fatima, Tamblyn, Robert · 1993 · New England Journal of Medicine
Cited by 147

The DOI matches its Crossref record.

Abstract

BACKGROUND: The sick building syndrome is the term given to a constellation of symptoms reported by workers in modern office buildings, hypothesized to occur when the supply of outdoor air is reduced, because of the accumulation of contaminants arising from within the building. We undertook this study to determine the effect of changing the supply of outdoor air in four office buildings on the symptoms reported by workers and their perception of the indoor environment. METHODS: Within each of three consecutive two-week blocks, the ventilation systems in each building were manipulated, in random order, to deliver to the indoor environment an intended 20 or 50 ft3 (0.57 or 1.4 m3) of outdoor air per minute per person for one week at a time. Each week, the participants, unaware of the experimental intervention, reported symptoms and the indoor environment was thoroughly evaluated. RESULTS: Of 1838 eligible workers in the four buildings, 1546 (84 percent) participated in the study. The supply of outdoor air averaged 7 percent and 32 percent in the ventilation systems and 30 and 64 ft3 (0.85 and 1.8 m3) per minute per person in the work sites at the lower and higher ventilation levels, respectively. These changes in the supply of outdoor air were not associated with changes in the participants' ratings of the office environment or in symptom frequency (crude odds ratio, 1.0; 95 percent confidence interval, 0.9 to 1.1). After work-site measures of ventilation, temperature, humidity, and air velocity were included in the regression analysis, the adjusted odds ratio was also 1.0 (95 percent confidence interval, 0.8 to 1.2). CONCLUSIONS: Increases in the supply of outdoor air did not appear to affect workers' perceptions of their office environment or their reporting of symptoms considered typical of the sick building syndrome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199303253281201

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 147

Metadata

Authors
Menzies, R., Tamblyn, R., Farant, J.-P., Hanley, J., Nunes, F., & Tamblyn, R.
Venue
New England Journal of Medicine
Published
1993-03-25
Volume
328
Issue
12
Pages
821-827
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W1972107045
Cited by
147
References
0
FWCI
17.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effect of Varying Levels of Outdoor-Air Supply on the Symptoms of Sick Building Syndrome. https://app.cochat.ai/papers/10.1056/nejm199303253281201
The paper
Menzies, R., Tamblyn, R., Farant, J.-P., Hanley, J., Nunes, F., & Tamblyn, R. (1993). The Effect of Varying Levels of Outdoor-Air Supply on the Symptoms of Sick Building Syndrome. New England Journal of Medicine. https://doi.org/10.1056/nejm199303253281201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.