Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 321

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The Diagnosis and Treatment of Baroreflex Failure

Open access
Robertson, David, Hollister, Alan S., Biaggioni, Italo, Netterville, James L., Mosqueda-Garcia, Rogelio, Robertson, Rose Marie·1993·New England Journal of Medicine

Abstract

BACKGROUND: Baroreflexes originate in the great vessels of the neck and thorax and prevent arterial pressure from rising or falling excessively. METHODS: This study was undertaken to clarify the cause, clinical spectrum, and therapy of this disorder. We studied 11 patients with baroreflex failure presenting as severe, labile hypertension and hypotension, often with headache, diaphoresis, and emotional instability, and characterized by the failure of exogenous vasoactive substances to alter heart rate. Each underwent hemodynamic monitoring and biochemical, physiologic, and pharmacologic testing. RESULTS: The patients' maximal systolic blood pressures ranged from 164 to 280 mm Hg, and their minimal systolic pressures ranged from 58 to 96 mm Hg. Plasma norepinephrine and epinephrine concentrations were sometimes many times normal during blood-pressure surges. All the patients had excessive pressor and tachycardia responses to the mental-arithmetic and cold pressor tests and marked hypersensitivity to clonidine. The underlying causes of baroreflex failure included the familial paraganglioma syndrome, neck surgery or radiation therapy for pharyngeal carcinoma, bilateral lesions of the nucleus tractus solitarii, and surgical section of the glossopharyngeal nerves; in two patients the cause was unknown. Therapy with clonidine reduced the frequency of attacks by 81 percent and attenuated the elevated blood pressure and heart rate in the attacks that occurred. CONCLUSIONS: The syndrome of baroreflex failure should be considered in patients with otherwise unexplained labile hypertension. Clonidine attenuates the pressor and tachycardic surges in baroreflex failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199311113292003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 321

Metadata

Authors
Robertson, D., Hollister, A. S., Biaggioni, I., Netterville, J. L., Mosqueda-Garcia, R., & Robertson, R. M.
Venue
New England Journal of Medicine
Published
1993-11-11
Volume
329
Issue
20
Pages
1449-1455
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2315875589
Cited by
321
References
1
FWCI
6.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Diagnosis and Treatment of Baroreflex Failure. https://app.cochat.ai/papers/10.1056/nejm199311113292003
The paper
Robertson, D., Hollister, A. S., Biaggioni, I., Netterville, J. L., Mosqueda-Garcia, R., & Robertson, R. M. (1993). The Diagnosis and Treatment of Baroreflex Failure. New England Journal of Medicine. https://doi.org/10.1056/nejm199311113292003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.