A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery Disease
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as compared with standard balloon angioplasty. METHODS: A total of 520 patients with stable angina and a single coronary-artery lesion were randomly assigned to either stent implantation (262 patients) or standard balloon angioplasty (258 patients). The primary clinical end points were death, the occurrence of a cerebrovascular accident, myocardial infarction, the need for coronary-artery bypass surgery, or a second percutaneous intervention involving the previously treated lesion, either at the time of the initial procedure or during the subsequent seven months. The primary angiographic end point was the minimal luminal diameter at follow-up, as determined by quantitative coronary angiography. RESULTS: After exclusions, 52 patients in the stent group (20 percent) and 76 patients in the angioplasty group (30 percent) reached a primary clinical end point (relative risk, 0.68; 95 percent confidence interval, 0.50 to 0.92; P = 0.02). The difference in clinical-event rates was explained mainly by a reduced need for a second coronary angioplasty in the stent group (relative risk, 0.58; 95 percent confidence interval, 0.40 to 0.85; P = 0.005). The mean (+/- SD) minimal luminal diameters immediately after the procedure were 2.48 +/- 0.39 mm in the stent group and 2.05 +/- 0.33 mm in the angioplasty group; at follow-up, the diameters were 1.82 +/- 0.64 mm in the stent group and 1.73 +/- 0.55 mm in the angioplasty group (P = 0.09), which correspond to rates of restenosis (diameter of stenosis, > or = 50 percent) of 22 and 32 percent, respectively (P = 0.02). Peripheral vascular complications necessitating surgery, blood transfusion, or both were more frequent after stenting than after balloon angioplasty (13.5 vs. 3.1 percent, P < 0.001). The mean hospital stay was significantly longer in the stent group than in the angioplasty group (8.5 vs. 3.1 days, P < 0.001). CONCLUSIONS: Over seven months of follow-up, the clinical and angiographic outcomes were better in patients who received a stent than in those who received standard coronary angioplasty. However, this benefit was achieved at the cost of a significantly higher risk of vascular complications at the access site and a longer hospital stay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Self-citationThe Electrocardiogram in Population Studies: A Classification System
BLACKBURN, H., KEYS, A., SIMONSON, E., RAUTAHARJU, P., & PUNSAR, S. (1960) · Circulation · doi:10.1161/01.cir.21.6.1160 · Cited by 1,109
Angiographie morphology and the pathogenesis of unstable angina pectoris
Ambrose, J. A., Winters, S. L., Stern, A., Eng, A., Teichholz, L. E., Gorlin, R., & Fuster, V. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80384-3 · Cited by 801
Estimation of a Common Effect Parameter from Sparse Follow-Up Data
Greenland, S., & Robins, J. M. (1985) · Biometrics · doi:10.2307/2530643 · Cited by 794
Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery Stent
Serruys, P. W., Strauss, B. H., Beatt, K. J., Bertrand, M. E., Puel, J., Rickards, A. F., Meier, B., Goy, J.-J., Vogt, P., Kappenberger, L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240103 · Cited by 732
Self-citationRoubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.916 · Cited by 582
Hirshfeld, J. W., Schwartz, J. S., Jugo, R., Macdonald, R. G., Goldberg, S., Savage, M. P., Bass, T. A., Vetrovec, G., Cowley, M., Taussig, A. S., et al. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90783-6 · Cited by 391
Thornton, M. A., Gruentzig, A. R., Hollman, J., King, S. B., & Douglas, J. S. (1984) · Circulation · doi:10.1161/01.cir.69.4.721 · Cited by 358
Interim Analyses for Randomized Clinical Trials: The Group Sequential Approach
Pocock, S. J. (1982) · Biometrics · doi:10.2307/2530298 · Cited by 264
Restenosis after coronary angioplasty: The paradox of increased lumen diameter and restenosis
Beatt, K. J., Serruys, P. W. J. C., Luijten, H. E., Rensing, B. J. W. M., Suryapranata, H., de Feyter, P. J., van den Brand, M., Laarman, G., Roelandt, J. R. T. C., & van Es, G. A. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90475-3 · Cited by 146
Self-citationCohen, D. J., Breall, J. A., Ho, K. K. L., Kuntz, R. E., Goldman, L., Baim, D. S., & Weinstein, M. C. (1994) · Circulation · doi:10.1161/01.cir.89.4.1859 · Cited by 143
Cited by
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationWriting Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“The frequency of restenosis after angioplasty has been correlated with impaired blood flow with low shear stress, which augments the inward vessel remodeling, cell migration, and activity of genes regulating migration, and significantly exacerbates the reduction in luminal size observed several months after the proced…”
Background
Metadata
- Authors
- Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., Belardi, J., Sigwart, U., Colombo, A., Goy, J. J., van den Heuvel, P., Delcan, J., & Morel, M.-A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1994-08-25
- Volume
- 331
- Issue
- 8
- Pages
- 489-495
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2020906145
- Cited by
- 4,556
- References
- 11
- FWCI
- 249.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.