A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery Disease
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as compared with standard balloon angioplasty. METHODS: A total of 520 patients with stable angina and a single coronary-artery lesion were randomly assigned to either stent implantation (262 patients) or standard balloon angioplasty (258 patients). The primary clinical end points were death, the occurrence of a cerebrovascular accident, myocardial infarction, the need for coronary-artery bypass surgery, or a second percutaneous intervention involving the previously treated lesion, either at the time of the initial procedure or during the subsequent seven months. The primary angiographic end point was the minimal luminal diameter at follow-up, as determined by quantitative coronary angiography. RESULTS: After exclusions, 52 patients in the stent group (20 percent) and 76 patients in the angioplasty group (30 percent) reached a primary clinical end point (relative risk, 0.68; 95 percent confidence interval, 0.50 to 0.92; P = 0.02). The difference in clinical-event rates was explained mainly by a reduced need for a second coronary angioplasty in the stent group (relative risk, 0.58; 95 percent confidence interval, 0.40 to 0.85; P = 0.005). The mean (+/- SD) minimal luminal diameters immediately after the procedure were 2.48 +/- 0.39 mm in the stent group and 2.05 +/- 0.33 mm in the angioplasty group; at follow-up, the diameters were 1.82 +/- 0.64 mm in the stent group and 1.73 +/- 0.55 mm in the angioplasty group (P = 0.09), which correspond to rates of restenosis (diameter of stenosis, > or = 50 percent) of 22 and 32 percent, respectively (P = 0.02). Peripheral vascular complications necessitating surgery, blood transfusion, or both were more frequent after stenting than after balloon angioplasty (13.5 vs. 3.1 percent, P < 0.001). The mean hospital stay was significantly longer in the stent group than in the angioplasty group (8.5 vs. 3.1 days, P < 0.001). CONCLUSIONS: Over seven months of follow-up, the clinical and angiographic outcomes were better in patients who received a stent than in those who received standard coronary angioplasty. However, this benefit was achieved at the cost of a significantly higher risk of vascular complications at the access site and a longer hospital stay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Self-citationThe Electrocardiogram in Population Studies: A Classification System
BLACKBURN, H., KEYS, A., SIMONSON, E., RAUTAHARJU, P., & PUNSAR, S. (1960) · Circulation · doi:10.1161/01.cir.21.6.1160 · Cited by 1,109
Angiographie morphology and the pathogenesis of unstable angina pectoris
Ambrose, J. A., Winters, S. L., Stern, A., Eng, A., Teichholz, L. E., Gorlin, R., & Fuster, V. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80384-3 · Cited by 801
Estimation of a Common Effect Parameter from Sparse Follow-Up Data
Greenland, S., & Robins, J. M. (1985) · Biometrics · doi:10.2307/2530643 · Cited by 794
Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery Stent
Serruys, P. W., Strauss, B. H., Beatt, K. J., Bertrand, M. E., Puel, J., Rickards, A. F., Meier, B., Goy, J.-J., Vogt, P., Kappenberger, L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240103 · Cited by 732
Self-citationRoubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.916 · Cited by 582
Hirshfeld, J. W., Schwartz, J. S., Jugo, R., Macdonald, R. G., Goldberg, S., Savage, M. P., Bass, T. A., Vetrovec, G., Cowley, M., Taussig, A. S., et al. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90783-6 · Cited by 391
Thornton, M. A., Gruentzig, A. R., Hollman, J., King, S. B., & Douglas, J. S. (1984) · Circulation · doi:10.1161/01.cir.69.4.721 · Cited by 358
Interim Analyses for Randomized Clinical Trials: The Group Sequential Approach
Pocock, S. J. (1982) · Biometrics · doi:10.2307/2530298 · Cited by 264
Restenosis after coronary angioplasty: The paradox of increased lumen diameter and restenosis
Beatt, K. J., Serruys, P. W. J. C., Luijten, H. E., Rensing, B. J. W. M., Suryapranata, H., de Feyter, P. J., van den Brand, M., Laarman, G., Roelandt, J. R. T. C., & van Es, G. A. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90475-3 · Cited by 146
Self-citation
Cited by
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationWriting Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“The frequency of restenosis after angioplasty has been correlated with impaired blood flow with low shear stress, which augments the inward vessel remodeling, cell migration, and activity of genes regulating migration, and significantly exacerbates the reduction in luminal size observed several months after the proced…”
BackgroundWRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
Cannon, C. P., Weintraub, W. S., Demopoulos, L. A., Vicari, R., Frey, M. J., Lakkis, N., Neumann, F.-J., Robertson, D. H., DeLucca, P. T., DiBattiste, P. M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106213442501 · Cited by 2,103
Schömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
ACC/AHA guidelines for coronary artery bypass graft surgery
Eagle, K. A., Guyton, R. A., Davidoff, R., Ewy, G. A., Fonger, J., Gardner, T. J., Gott, J. P., Herrmann, H. C., Marlow, R. A., Nugent, W. C., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00389-7 · Cited by 1,995
A Clinical Trial Comparing Three Antithrombotic-Drug Regimens after Coronary-Artery Stenting
Leon, M. B., Baim, D. S., Popma, J. J., Gordon, P. C., Cutlip, D. E., Ho, K. K. L., Giambartolomei, A., Diver, D. J., Lasorda, D. M., Williams, D. O., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812033392303 · Cited by 1,815
Guidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Self-citationComparison of Coronary Bypass Surgery with Angioplasty in Patients with Multivessel Disease
(1996) · New England Journal of Medicine · doi:10.1056/nejm199607253350401 · Cited by 1,531
Contradicted and Initially Stronger Effects in Highly Cited Clinical Research
Ioannidis, J. P. A. (2005) · JAMA · doi:10.1001/jama.294.2.218 · Cited by 1,465
Stent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents
Mauri, L., Hsieh, W.-H., Massaro, J. M., Ho, K. K. L., D'Agostino, R., & Cutlip, D. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067731 · Cited by 1,441
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Self-citationComparison of Angioplasty with Stenting, with or without Abciximab, in Acute Myocardial Infarction
Stone, G. W., Grines, C. L., Cox, D. A., Garcia, E., Tcheng, J. E., Griffin, J. J., Guagliumi, G., Stuckey, T., Turco, M., Carroll, J. D., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013404 · Cited by 1,277
Angiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Platelet Glycoprotein IIb/IIIa Inhibition with Coronary Stenting for Acute Myocardial Infarction
Montalescot, G., Barragan, P., Wittenberg, O., Ecollan, P., Elhadad, S., Villain, P., Boulenc, J.-M., Morice, M.-C., Maillard, L., Pansiéri, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106213442503 · Cited by 1,186
Topol, E. J., & Nissen, S. E. (1995) · Circulation · doi:10.1161/01.cir.92.8.2333 · Cited by 1,103
Topol, E. J. (1998) · The Lancet · doi:10.1016/s0140-6736(98)85010-1 · Cited by 1,095
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
(1997) · New England Journal of Medicine · doi:10.1056/nejm199706053362301 · Cited by 948
Catheter-Based Radiotherapy to Inhibit Restenosis after Coronary Stenting
Teirstein, P. S., Massullo, V., Jani, S., Popma, J. J., Mintz, G. S., Russo, R. J., Schatz, R. A., Guarneri, E. M., Steuterman, S., Morris, N. B., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362402 · Cited by 942
Kastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schühlen, H., Neumann, F.-J., Fleckenstein, M., Pfafferott, C., Seyfarth, M., & Schömig, A. (2001) · Circulation · doi:10.1161/01.cir.103.23.2816 · Cited by 938
The Pathology of Neoatherosclerosis in Human Coronary Implants
Nakazawa, G., Otsuka, F., Nakano, M., Vorpahl, M., Yazdani, S. K., Ladich, E., Kolodgie, F. D., Finn, A. V., & Virmani, R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.011 · Cited by 934
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Drug-Eluting Stent and Coronary Thrombosis: Biological Mechanisms and Clinical Implications
Lüscher, T. F., Steffel, J., Eberli, F. R., Joner, M., Nakazawa, G., Tanner, F. C., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.106.675934 · Cited by 906
COMMITTEE MEMBERS, Eagle, K. A., Guyton, R. A., Davidoff, R., Edwards, F. H., Ewy, G. A., Gardner, T. J., Hart, J. C., Herrmann, H. C., Hillis, L. D., et al. (2004) · Circulation · doi:10.1161/01.cir.0000138790.14877.7d · Cited by 893
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Pathology of Acute and Chronic Coronary Stenting in Humans
Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., & Virmani, R. (1999) · Circulation · doi:10.1161/01.cir.99.1.44 · Cited by 871
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Stent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.15.1967 · Cited by 855
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Self-citationKornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Vascular proliferation and atherosclerosis: New perspectives and therapeutic strategies
Dzau, V. J., Braun-Dullaeus, R. C., & Sedding, D. G. (2002) · Nature Medicine · doi:10.1038/nm1102-1249 · Cited by 831
Camenzind, E., Steg, P. G., & Wijns, W. (2007) · Circulation · doi:10.1161/circulationaha.106.666800 · Cited by 818
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Hambrecht, R., Walther, C., Möbius-Winkler, S., Gielen, S., Linke, A., Conradi, K., Erbs, S., Kluge, R., Kendziorra, K., Sabri, O., et al. (2004) · Circulation · doi:10.1161/01.cir.0000121360.31954.1f · Cited by 752
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Self-citationKuribayashi, K., Tsuchiya, K., You, Z., Tomus, D., Umemoto, M., Ito, T., & Sasaki, M. (2006) · Materials Science and Engineering: A · doi:10.1016/j.msea.2005.12.016 · Cited by 755
Drug-Eluting Coronary-Artery Stents
Stefanini, G. G., & Holmes, D. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1210816 · Cited by 728
Awtry, E. H., & Loscalzo, J. (2000) · Circulation · doi:10.1161/01.cir.101.10.1206 · Cited by 690
Predictive Factors of Restenosis After Coronary Stent Placement
Kastrati, A., Schömig, A., Elezi, S., Schühlen, H., Dirschinger, J., Hadamitzky, M., Wehinger, A., Hausleiter, J., Walter, H., & Neumann, F.-J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00334-3 · Cited by 685
Serruys, P. W., van Hout, B., Bonnier, H., Legrand, V., Garcia, E., Macaya, C., Sousa, E., van der Giessen, W., Colombo, A., Seabra-Gomes, R., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11128-x · Cited by 650
Self-citationA hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
Babapulle, M. N., Joseph, L., Bélisle, P., Brophy, J. M., & Eisenberg, M. J. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16850-5 · Cited by 645
Inflammation and Restenosis in the Stent Era
Welt, F. G. P., & Rogers, C. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000037100.44766.5b · Cited by 628
Investigators, T. B. (1997) · Circulation · doi:10.1161/01.cir.96.6.1761 · Cited by 619
Byrne, R. A., Joner, M., & Kastrati, A. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv511 · Cited by 609
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Developments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
The SSYLVIA Study Investigators (2004) · Stroke · doi:10.1161/01.str.0000128708.86762.d6 · Cited by 604
Drug-Coated Balloons for Coronary Artery Disease
Jeger, R. V., Eccleshall, S., Wan Ahmad, W. A., Ge, J., Poerner, T. C., Shin, E.-S., Alfonso, F., Latib, A., Ong, P. J., Rissanen, T. T., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.02.043 · Cited by 600
Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization
Windecker, S., Remondino, A., Eberli, F. R., Jüni, P., Räber, L., Wenaweser, P., Togni, M., Billinger, M., Tüller, D., Seiler, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051175 · Cited by 593
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Bertrand, M. E., Legrand, V., Boland, J., Fleck, E., Bonnier, J., Emmanuelson, H., Vrolix, M., Missault, L., Chierchia, S., Casaccia, M., et al. (1998) · Circulation · doi:10.1161/01.cir.98.16.1597 · Cited by 583
Self-citationHueb, W., Lopes, N. H., Gersh, B. J., Soares, P., Machado, L. A. C., Jatene, F. B., Oliveira, S. A., & Ramires, J. A. F. (2007) · Circulation · doi:10.1161/circulationaha.106.625475 · Cited by 576
Schampaert, E., Cohen, E. A., Schlüter, M., Reeves, F., Traboulsi, M., Title, L. M., Kuntz, R. E., & Popma, J. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.024 · Cited by 575
Percutaneous Recanalization of Chronically Occluded Coronary Arteries: A Consensus Document: Part II
Stone, G. W., Reifart, N. J., Moussa, I., Hoye, A., Cox, D. A., Colombo, A., Baim, D. S., Teirstein, P. S., Strauss, B. H., Selmon, M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.583716 · Cited by 562
Self-citationBonello, L., Camoin-Jau, L., Arques, S., Boyer, C., Panagides, D., Wittenberg, O., Simeoni, M.-C., Barragan, P., Dignat-George, F., & Paganelli, F. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.12.044 · Cited by 556
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Decreased Rate of Coronary Restenosis after Lowering of Plasma Homocysteine Levels
Schnyder, G., Roffi, M., Pin, R., Flammer, Y., Lange, H., Eberli, F. R., Meier, B., Turi, Z. G., & Hess, O. M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011364 · Cited by 532
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
Meta-analysis of randomised trials comparing coronary angioplasty with bypass surgery
Pocock, S. J., Henderson, R. A., Rickards, A. F., Hampton, J. R., King, S. B., Hamm, C. W., Puel, J., Hueb, W., Goy, J.-J., & Rodriguez, A. (1995) · The Lancet · doi:10.1016/s0140-6736(95)92897-9 · Cited by 530
Self-citationHolmes, D. R., Leon, M. B., Moses, J. W., Popma, J. J., Cutlip, D., Fitzgerald, P. J., Brown, C., Fischell, T., Wong, S. C., Midei, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112572.57794.22 · Cited by 515
Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., Yokoi, H., Hamasaki, N., Nosaka, H., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340903 · Cited by 507
Recombinant collagen and gelatin for drug delivery
Olsen, D. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.008 · Cited by 506
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Self-citationDiabetes mellitus and the clinical and angiographic outcome after coronary stent placement
Elezi, S., Kastrati, A., Pache, J., Wehinger, A., Hadamitzky, M., Dirschinger, J., Neumann, F.-J., & Schömig, A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00467-7 · Cited by 495
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
“, an endovascular stent) mitigates incidence of restenosis compared to balloon angioplasty alone [19,20].”
BackgroundStent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
Savage, M. P., Douglas, J. S., Fischman, D. L., Pepine, C. J., King, S. B., Werner, J. A., Bailey, S. R., Overlie, P. A., Fenton, S. H., Brinker, J. A., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371103 · Cited by 486
Vessel Size and Long-Term Outcome After Coronary Stent Placement
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A. (1998) · Circulation · doi:10.1161/01.cir.98.18.1875 · Cited by 484
Nordmann, A. J., Briel, M., & Bucher, H. C. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl282 · Cited by 480
Abizaid, A., Kornowski, R., Mintz, G. S., Hong, M. K., Abizaid, A. S., Mehran, R., Pichard, A. D., Kent, K. M., Satler, L. F., Wu, H., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00286-1 · Cited by 458
Wiviott, S. D., Braunwald, E., McCabe, C. H., Horvath, I., Keltai, M., Herrman, J.-P. R., Van de Werf, F., Downey, W. E., Scirica, B. M., Murphy, S. A., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60422-5 · Cited by 453
Urban, P., Macaya, C., Rupprecht, H.-J., Kiemeneij, F., Emanuelsson, H., Fontanelli, A., Pieper, M., Wesseling, T., & Sagnard, L. (1998) · Circulation · doi:10.1161/01.cir.98.20.2126 · Cited by 445
Self-citationHeldman, A. W., Cheng, L., Jenkins, G. M., Heller, P. F., Kim, D.-W., Ware, M., Nater, C., Hruban, R. H., Rezai, B., Abella, B. S., et al. (2001) · Circulation · doi:10.1161/01.cir.103.18.2289 · Cited by 435
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Self-citationBarragan, P., Bouvier, J., Roquebert, P., Macaluso, G., Commeau, P., Comet, B., Lafont, A., Camoin, L., Walter, U., & Eigenthaler, M. (2003) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.10497 · Cited by 434
Snoep, J. D., Hovens, M. M. C., Eikenboom, J. C. J., van der Bom, J. G., Jukema, J. W., & Huisman, M. V. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.04.014 · Cited by 427
Clinical restenosis after coronary stenting: perspectives from multicenter clinical trials
Cutlip, D. E., Chauhan, M. S., Baim, D. S., Ho, K. K. L., Popma, J. J., Carrozza, J. P., Cohen, D. J., & Kuntz, R. E. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02597-4 · Cited by 423
Coronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Bare metal stent restenosis is not a benign clinical entity
Chen, M. S., John, J. M., Chew, D. P., Lee, D. S., Ellis, S. G., & Bhatt, D. L. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.08.011 · Cited by 413
Serruys, P. W., Emanuelsson, H., van der Giessen, W., Lunn, A. C., Kiemeney, F., Macaya, C., Rutsch, W., Heyndrickx, G., Suryapranata, H., Legrand, V., et al. (1996) · Circulation · doi:10.1161/01.cir.93.3.412 · Cited by 408
Self-citationHoffman, S. N., TenBrook, J. A., Wolf, M. P., Wong, J. B., Pauker, S. G., & Salem, D. N. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00157-8 · Cited by 407
Grewe, P. H., Deneke, T., Machraoui, A., Barmeyer, J., & Müller, K.-M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00486-6 · Cited by 401
Topol, E. J. (1997) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1997.03550060055036 · Cited by 399
(2003) · OECD Health Working Papers · doi:10.1787/230112362071 · Cited by 381
Batchelor, W. B., Anstrom, K. J., Muhlbaier, L. H., Grosswald, R., Weintraub, W. S., O’Neill, W. W., & Peterson, E. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00777-4 · Cited by 381
Rodriguez, A., Bernardi, V., Navia, J., Baldi, J., Grinfeld, L., Martinez, J., Vogel, D., Grinfeld, R., Delacasa, A., Garrido, M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01052-4 · Cited by 372
Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372
Drug-eluting stents in vascular intervention
Fattori, R., & Piva, T. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12275-1 · Cited by 365
Latib, A., Colombo, A., Castriota, F., Micari, A., Cremonesi, A., De Felice, F., Marchese, A., Tespili, M., Presbitero, P., Sgueglia, G. A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.020 · Cited by 364
Self-citationMeta-analysis of randomized and registry comparisons of ticlopidine with clopidogrel after stenting
Bhatt, D. L., Bertrand, M. E., Berger, P. B., L’Allier, P. L., Moussa, I., Moses, J. W., Dangas, G., Taniuchi, M., Lasala, J. M., Holmes, D. R., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01713-2 · Cited by 362
Windecker, S., Stortecky, S., Stefanini, G. G., daCosta, B. R., Rutjes, A. W., Di Nisio, M., Siletta, M. G., Maione, A., Alfonso, F., Clemmensen, P. M., et al. (2014) · BMJ · doi:10.1136/bmj.g3859 · Cited by 356
Ong, A. T. L., Serruys, P. W., Mohr, F. W., Morice, M.-C., Kappetein, A. P., Holmes, D. R., Mack, M. J., van den Brand, M., Morel, M.-A., van Es, G.-A., et al. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.07.017 · Cited by 338
Self-citation
Metadata
- Authors
- Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., Belardi, J., Sigwart, U., Colombo, A., Goy, J. J., van den Heuvel, P., Delcan, J., & Morel, M.-A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1994-08-25
- Volume
- 331
- Issue
- 8
- Pages
- 489-495
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2020906145
- Cited by
- 4,556
- References
- 11
- FWCI
- 249.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.