Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,678

The DOI matches its Crossref record.

Transluminal Placement of Endovascular Stent-Grafts for the Treatment of Descending Thoracic Aortic Aneurysms

Open access
Dake, Michael D., Miller, D. Craig, Semba, Charles P., Mitchell, R. Scott, Walker, Philip J., Liddell, Robert P.·1994·New England Journal of Medicine

Abstract

BACKGROUND: The usual treatment for thoracic aortic aneurysms is surgical replacement with a prosthetic graft, but the associated morbidity and mortality are considerable. We studied the use of transluminally placed endovascular stent-graft devices as an alternative to surgical repair. METHODS: We evaluated the feasibility, safety, and effectiveness of transluminally placed stent-graft to treat descending thoracic aortic aneurysms in 13 patients over a 24-month period. Atherosclerotic, anastomotic, and post-traumatic true or false aneurysms and aortic dissections were treated. The mean diameter of the aneurysms was 6.1 cm (range, 5 to 8). The endovascular stent-grafts were custom-designed for each patient and were constructed of self-expanding stainless-steel stents covered with woven Dacron grafts. RESULTS: Endovascular placement of the stent-graft prosthesis was successful in all patients. There was complete thrombosis of the thoracic aortic aneurysm surrounding the stent-graft in 12 patients, and partial thrombosis in 1. Two patients initially had small, residual patent proximal tracts into the aneurysm sac, but both tracts thrombosed within two months after the procedure. In four patients, two prostheses were required to bridge the aneurysm adequately. There have been no deaths or instances of paraplegia, stroke, distal embolization, or infection during an average follow-up of 11.6 months. One patient with an extensive chronic aortic dissection required open surgical graft replacement four months later because of progressive dilatation of the arch. CONCLUSIONS: These preliminary results demonstrate that endovascular stent-graft repair is safe in highly selected patients with descending thoracic aortic aneurysms. This new method of treatment will, however, require careful long-term evaluation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199412293312601

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,678

Metadata

Authors
Dake, M. D., Miller, D. C., Semba, C. P., Mitchell, R. S., Walker, P. J., & Liddell, R. P.
Venue
New England Journal of Medicine
Published
1994-12-29
Volume
331
Issue
26
Pages
1729-1734
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2026673368
Cited by
1,678
References
0
FWCI
34.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transluminal Placement of Endovascular Stent-Grafts for the Treatment of Descending Thoracic Aortic Aneurysms. https://app.cochat.ai/papers/10.1056/nejm199412293312601
The paper
Dake, M. D., Miller, D. C., Semba, C. P., Mitchell, R. S., Walker, P. J., & Liddell, R. P. (1994). Transluminal Placement of Endovascular Stent-Grafts for the Treatment of Descending Thoracic Aortic Aneurysms. New England Journal of Medicine. https://doi.org/10.1056/nejm199412293312601

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.