The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
Open accessAbstract
BACKGROUND: Coronary-artery stents are known to reduce rates of restenosis after coronary angioplasty, but it is uncertain how long this benefit is maintained. METHODS: We evaluated clinical and angiographic follow-up information for up to three years after the implantation of Palmaz-Schatz metallic coronary-artery stents in 143 patients with 147 lesions of native coronary arteries. RESULTS: The rate of survival free of myocardial infarction, bypass surgery, and repeated coronary angioplasty for stented lesions was 74.6 percent at three years. After 14 months, revascularization of the stented lesion was necessary in only three patients (2.1 percent). In contrast, coronary angioplasty for a new lesion was required in 11 patients (7.7 percent). Follow-up coronary angiography of 137 lesions at six months, 114 lesions at one year, and 72 lesions at three years revealed a decrease in minimal luminal diameter from 2.54 +/- 0.44 mm immediately after stent implantation to 1.87 +/- 0.56 mm at six months, but no further decrease in diameter at one year (in patients with paired angiograms, 1.95 +/- 0.49 mm at both six months and one year). Significant late improvement in luminal diameter was observed at three years (in patients with paired angiograms, 1.94 +/- 0.48 mm at six months and 2.09 +/- 0.48 mm at three years; P < 0.001). CONCLUSIONS: Clinical and angiographic outcomes up to three years after coronary-artery stenting were favorable, with a low rate of revascularization of the stented lesions. Late improvement in luminal diameter appears to occur between six months and three years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationIntravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Nobuyoshi, M., Kimura, T., Nosaka, H., Mioka, S., Ueno, K., Yokoi, H., Hamasaki, N., Horiuchi, H., & Ohishi, H. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(88)80046-9 · Cited by 875
Self-citationRoubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.916 · Cited by 582
Nobuyoshi, M., Kimura, T., Ohishi, H., Horiuchi, H., Nosaka, H., Hamasaki, N., Yokoi, H., & Kim, K. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80111-1 · Cited by 400
Self-citationIntracoronary ultrasound observations during stent implantation.
Nakamura, S., Colombo, A., Gaglione, A., Almagor, Y., Goldberg, S. L., Maiello, L., Finci, L., & Tobis, J. M. (1994) · Circulation · doi:10.1161/01.cir.89.5.2026 · Cited by 394
Midterm outcome of patients with asymptomatic restenosis after coronary balloon angioplasty
Hernández, R. A., Macaya, C., Íñiguez, A., Alfonso, F., Goicolea, J., Fernández‐Ortíz, A., & Zarco, P. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90594-d · Cited by 62
Cited by
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Nelson, P. K., Lylyk, P., Szikora, I., Wetzel, S. G., Wanke, I., & Fiorella, D. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2421 · Cited by 843
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Byrne, R. A., Joner, M., & Kastrati, A. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv511 · Cited by 609
Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization
Windecker, S., Remondino, A., Eberli, F. R., Jüni, P., Räber, L., Wenaweser, P., Togni, M., Billinger, M., Tüller, D., Seiler, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051175 · Cited by 593
Metadata
- Authors
- Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., Yokoi, H., Hamasaki, N., Nosaka, H., & Nobuyoshi, M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1996-02-29
- Volume
- 334
- Issue
- 9
- Pages
- 561-567
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1999124647
- Cited by
- 507
- References
- 9
- FWCI
- 49.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents. https://app.cochat.ai/papers/10.1056/nejm199602293340903
- The paper
- Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., Yokoi, H., Hamasaki, N., Nosaka, H., & Nobuyoshi, M. (1996). Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents. New England Journal of Medicine. https://doi.org/10.1056/nejm199602293340903
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.