The Reproducibility of a Method to Identify the Overuse and Underuse of Medical Procedures
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To assess the overuse and underuse of medical procedures, various methods have been developed, but their reproducibility has not been evaluated. This study estimates the reproducibility of one commonly used method. METHODS: We performed a parallel, three-way replication of the RAND-University of California at Los Angeles appropriateness method as applied to two medical procedures, coronary revascularization and hysterectomy. Three nine-member multidisciplinary panels of experts were composed for each procedure by stratified random sampling from a list of experts nominated by the relevant specialty societies. Each panel independently rated the same set of clinical scenarios in terms of the appropriateness of the relevant procedure on a risk-benefit scale ranging from 1 to 9. Final ratings were used to classify the procedure in each scenario as necessary or not necessary (to evaluate underuse) and inappropriate or not inappropriate (to evaluate overuse). Reproducibility was measured by overall agreement and by the kappa statistic. The criteria for underuse and overuse derived from these ratings were then applied to real populations of patients who had undergone coronary revascularization or hysterectomy. RESULTS: The rates of agreement among the three coronary-revascularization panels were 95, 94, and 96 percent for inappropriate-use scenarios and 93, 92, and 92 percent for necessary-use scenarios. Agreement among the three hysterectomy panels was 88, 70, and 74 percent for inappropriate-use scenarios. Scenarios involving necessary use of hysterectomy were not assessed. The three-way kappa statistic to detect overuse was 0.52 for coronary revascularization and 0.51 for hysterectomy. The three-way kappa statistic to detect underuse of coronary revascularization was 0.83. Application of individual panels' criteria to real populations of patients resulted in a 100 percent variation in the proportion of cases classified as inappropriate and a 20 percent variation in the proportion of cases classified as necessary. CONCLUSIONS: The appropriateness method is far from perfect. Appropriateness criteria may be useful in comparing levels of appropriate procedures among populations but should not by themselves be used to direct care for individual patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Discrepancies between Meta-Analyses and Subsequent Large Randomized, Controlled Trials
LeLorier, J., Grégoire, G., Benhaddad, A., Lapierre, J., & Derderian, F. (1997) · New England Journal of Medicine · doi:10.1056/nejm199708213370806 · Cited by 1,171
A Method for the Detailed Assessment of the Appropriateness of Medical Technologies
Brook, R. H., Chassin, M. R., Fink, A., Solomon, D. H., Kosecoff, J., & Park, R. E. (1986) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462300002774 · Cited by 762
Self-citationVariability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
The Cost Effectiveness of Preoperative Autologous Blood Donations
Etchason, J., Petz, L., Keeler, E., Calhoun, L., Kleinman, S., Snider, C., Fink, A., & Brook, R. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503163321106 · Cited by 495
Variability in the analysis of coronary arteriograms.
DeRouen, T. A., Murray, J. A., & Owen, W. (1977) · Circulation · doi:10.1161/01.cir.55.2.324 · Cited by 485
Observer variation in histopathological diagnosis and grading of cervical intraepithelial neoplasia.
Ismail, S. M., Colclough, A. B., Dinnen, J. S., Eakins, D., Evans, D. M., Gradwell, E., O'Sullivan, J. P., Summerell, J. M., & Newcombe, R. G. (1989) · BMJ · doi:10.1136/bmj.298.6675.707 · Cited by 383
Large trials vs meta-analysis of smaller trials: how do their results compare?
Cappelleri, J. C., Ioannidis, J., Schmid, C., de Ferranti, S., Aubert, M., Chalmers, T. C., & Lau, J. (1996) · Journal of the American Medical Association (JAMA) · doi:10.1001/jama.276.16.1332 · Cited by 340
Desforges, J. F., Carlson, K. J., Nichols, D. H., & Schiff, I. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281207 · Cited by 336
The cost‐effectiveness of preoperative autologous blood donation for total hip and knee replacement
Birkmeyer, J. D., Goodnough, L. T., AuBuchon, J. P., Noordsij, P. G., & Littenberg, B. (1993) · Transfusion · doi:10.1046/j.1537-2995.1993.33793325048.x · Cited by 266
Cited by
The quality of health care delivered to adults in the United States
McGlynn, E. A., Asch, S. M., Adams, J., Keesey, J., Hicks, J., DeCristofaro, A., & Kerr, E. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa022615 · Cited by 5,079
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
(2001) · Defense Technical Information Center (DTIC) · Cited by 2,158
Incidence and Types of Adverse Events and Negligent Care in Utah and Colorado
Thomas, E. J., Studdert, D. M., Burstin, H. R., Orav, E. J., Zeena, T., Williams, E. J., Howard, K. M., Weiler, P. C., & Brennan, T. A. (2000) · Medical Care · doi:10.1097/00005650-200003000-00003 · Cited by 1,673
Grossman, J. M., Gordon, R., Ranganath, V. K., Deal, C., Caplan, L., Chen, W., Curtis, J. R., Furst, D. E., McMahon, M., Patkar, N. M., et al. (2010) · Arthritis Care & Research · doi:10.1002/acr.20295 · Cited by 708
Research methods used in developing and applying quality indicators in primary care
Campbell, S. M. (2002) · Quality and Safety in Health Care · doi:10.1136/qhc.11.4.358 · Cited by 687
Epstein, A. M., Ayanian, J. Z., Keogh, J. H., Noonan, S. J., Armistead, N., Cleary, P. D., Weissman, J. S., David-Kasdan, J. A., Carlson, D., Fuller, J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011233432106 · Cited by 569
Asch, S. M., McGlynn, E. A., Hogan, M. M., Hayward, R. A., Shekelle, P., Rubenstein, L., Keesey, J., Adams, J., & Kerr, E. A. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-12-200412210-00010 · Cited by 509
Self-citationConsensus Development Methods: A Review of Best Practice in Creating Clinical Guidelines
Black, N., Murphy, M., Lamping, D., McKee, M., Sanderson, C., Askham, J., & Marteau, T. (1999) · Journal of Health Services Research & Policy · doi:10.1177/135581969900400410 · Cited by 451
Sheldon, T. A., Cullum, N., Dawson, D., Lankshear, A., Lowson, K., Watt, I., West, P., Wright, D., & Wright, J. (2004) · BMJ · doi:10.1136/bmj.329.7473.999 · Cited by 433
Productivity Spillovers in Health Care: Evidence from the Treatment of Heart Attacks
Chandra, A., & Staiger, D. O. (2007) · Journal of Political Economy · doi:10.1086/512249 · Cited by 366
Chertow, G. M., Normand, S.-L. T., & McNeil, B. J. (2004) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000135969.33773.0b · Cited by 334
Which fractures are most attributable to osteoporosis?
Warriner, A. H., Patkar, N. M., Curtis, J. R., Delzell, E., Gary, L., Kilgore, M., & Saag, K. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.07.007 · Cited by 311
Adriaenssens, N., Coenen, S., Tonkin-Crine, S., Verheij, T. J. M., Little, P., & Goossens, H. (2011) · BMJ Quality & Safety · doi:10.1136/bmjqs.2010.049049 · Cited by 309
Sepucha, K. R., Fowler, F. J., & Mulley, A. G. (2004) · Health Affairs · doi:10.1377/hlthaff.var.54 · Cited by 297
Introduction: Methods, Commentary, and Summary
ALLEN, M. H., CURRIER, G. W., CARPENTER, D., ROSS, R. W., & DOCHERTY, J. P. (2005) · Journal of Psychiatric Practice · doi:10.1097/00131746-200511001-00002 · Cited by 267
Hemingway, H., Crook, A. M., Feder, G., Banerjee, S., Dawson, J. R., Magee, P., Philpott, S., Sanders, J., Wood, A., & Timmis, A. D. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103013440906 · Cited by 262
Poston, G. J., Adam, R., Alberts, S., Curley, S., Figueras, J., Haller, D., Kunstlinger, F., Mentha, G., Nordlinger, B., Patt, Y., et al. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.08.722 · Cited by 260
Self-citationCoenen, S., Ferech, M., Haaijer-Ruskamp, F. M., Butler, C. C., Vander Stichele, R. H., Verheij, T. J. M., Monnet, D. L., Little, P., Goossens, H., & the ESAC Project Group (2007) · Quality and Safety in Health Care · doi:10.1136/qshc.2006.021121 · Cited by 245
Mikuls, T. R., Johnson, S. R., Fraenkel, L., Arasaratnam, R. J., Baden, L. R., Bermas, B. L., Chatham, W., Cohen, S., Costenbader, K., Gravallese, E. M., et al. (2021) · Arthritis & Rheumatology · doi:10.1002/art.41596 · Cited by 241
“The RAND/UCLA appropriateness method has been shown to be highly reproducible (6) and to have content, construct, and predictive validity (7–9).”
MethodConsensus methods in prescribing research
Campbell, S. M., & Cantrill, J. A. (2001) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1046/j.1365-2710.2001.00331.x · Cited by 239
Wyrwich, K. W., Tierney, W. M., Babu, A. N., Kroenke, K., & Wolinsky, F. D. (2005) · Health Services Research · doi:10.1111/j.1475-6773.2005.0l374.x · Cited by 238
“Other key limitations include the use of only a single panel for each targeted disease (Shekelle et al. 1998), and the assumption of”
BackgroundAssessing Care of Vulnerable Elders: Methods for Developing Quality Indicators
Shekelle, P. G., MacLean, C. H., Morton, S. C., & Wenger, N. S. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-8_part_2-200110161-00003 · Cited by 232
“The reproducibility of the RAND/UCLA Appropriateness Method is consistent with that of well-accepted diagnostic tests, such as the interpretation of coronary angiography and screening mammography (18).”
MethodSelf-citationShekelle, P. (2004) · Medical Decision Making · doi:10.1177/0272989x04264212 · Cited by 204
“7 between similarly composed panels considering the same procedures.(6,7) Studies of testretest reliability with the same panelists have yielded a correlation coefficient exceeding 0.”
BackgroundSelf-citationBaicker, K., Buckles, K. S., & Chandra, A. (2006) · Health Affairs · doi:10.1377/hlthaff.25.w355 · Cited by 201
“variability, particularly for procedure use classified as inappropriate, and to be greatly influenced by the composition of the panel.(7)”
BackgroundThe appropriateness of recommendations for hysterectomy
Broder, M. (2000) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(99)00519-0 · Cited by 196
“51) across three expert panels who rated appropriateness of hysterectomy using identical methodology.(19) That level of reliability is significantly better than individual surgeons regarding need for hysterectomy.”
BackgroundMaking the Investment Count: Revision of the Minimum Data Set for Nursing Homes, MDS 3.0
Saliba, D., & Buchanan, J. (2012) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2012.06.002 · Cited by 186
Can health care quality indicators be transferred between countries?
Marshall, M. N. (2003) · Quality and Safety in Health Care · doi:10.1136/qhc.12.1.8 · Cited by 185
Mikuls, T. R., Johnson, S. R., Fraenkel, L., Arasaratnam, R. J., Baden, L. R., Bermas, B. L., Chatham, W., Cohen, S., Costenbader, K., Gravallese, E. M., et al. (2020) · Arthritis & Rheumatology · doi:10.1002/art.41301 · Cited by 179
“The RAND/UCLA appropriateness method has been shown to be highly reproducible (6) and to have content, construct, and predictive validity (7–9).”
MethodHidden Barriers to Improvement in the Quality of Care
McNeil, B. J. (2001) · New England Journal of Medicine · doi:10.1056/nejmsa011810 · Cited by 158
Schneider, E. C., Leape, L. L., Weissman, J. S., Piana, R. N., Gatsonis, C., & Epstein, A. M. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-5-200109040-00009 · Cited by 151
Self-citationWhat do consumers say they want and need during a psychiatric emergency?
ALLEN, M. H., CARPENTER, D., SHEETS, J. L., MICCIO, S., & ROSS, R. (2003) · Journal of Psychiatric Practice · doi:10.1097/00131746-200301000-00005 · Cited by 149
Zima, B. T., Hurlburt, M. S., Knapp, P., Ladd, H., Tang, L., Duan, N., Wallace, P., Rosenblatt, A., Landsverk, J., & Wells, K. B. (2005) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/00004583-200502000-00005 · Cited by 117
Uncertainties in the prevention and treatment of glucocorticoid-induced osteoporosis
Hansen, K. E., Wilson, H. A., Zapalowski, C., Fink, H. A., Minisola, S., & Adler, R. A. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.362 · Cited by 65
“8), and it seems likely that outcomes would also be sensitive to moderator effects.((22,23)) Further, guidelines derived using the RAND/UCLA approach may be valuable only as far as the evaluated scenarios capture real-life clinical decisionmaking dilemmas.”
MethodGeer, E. B., Ayala, A., Bonert, V., Carmichael, J. D., Gordon, M. B., Katznelson, L., Manuylova, E., Shafiq, I., Surampudi, V., Swerdloff, R. S., et al. (2017) · Pituitary · doi:10.1007/s11102-017-0801-2 · Cited by 11
Metadata
- Authors
- Shekelle, P. G., Kahan, J. P., Bernstein, S. J., Leape, L. L., Kamberg, C. J., & Park, R. E.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1998-06-25
- Volume
- 338
- Issue
- 26
- Pages
- 1888-1895
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2332704525
- Cited by
- 368
- References
- 29
- FWCI
- 66.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.