Integrated Screening for Down's Syndrome Based on Tests Performed during the First and Second Trimesters
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Both first-trimester screening and second-trimester screening for Down's syndrome are effective means of selecting women for chorionic-villus sampling or amniocentesis, but there is uncertainty about which screening method should be used in practice. We propose a new screening method in which measurements obtained during both trimesters are integrated to provide a single estimate of a woman's risk of having a pregnancy affected by Down's syndrome. METHODS: We used data from published studies of various screening methods employed during the first and second trimesters. The first-trimester screening consisted of measurement of serum pregnancy-associated plasma protein A in 77 pregnancies affected by Down's syndrome and 383 unaffected pregnancies and measurements of nuchal translucency obtained by ultrasonography in 326 affected and 95,476 unaffected pregnancies. The second-trimester tests were various combinations of measurements of serum alpha-fetoprotein, unconjugated estriol, human chorionic gonadotropin, and inhibin A in 77 affected and 385 unaffected pregnancies. RESULTS: When we used a risk of 1 in 120 or greater as the cutoff to define a positive result on the integrated screening test, the rate of detection of Down's syndrome was 85 percent, with a false positive rate of 0.9 percent. To achieve the same rate of detection, current screening tests would have higher false positive rates (5 to 22 percent). If the integrated test were to replace the triple test (measurements of serum alpha-fetoprotein, unconjugated estriol, and human chorionic gonadotropin), currently used with a 5 percent false positive rate, for screening during the second trimester, the detection rate would be higher 85 percent vs. 69 percent), with a reduction of four fifths in the number of invasive diagnostic procedures and consequent losses of normal fetuses. CONCLUSIONS: The integrated test detects more cases of Down's syndrome with a much lower false positive rate than the best currently available test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Maternal serum screening for Down's syndrome in early pregnancy.
Wald, N. J., Cuckle, H. S., Densem, J. W., Nanchahal, K., Royston, P., Chard, T., Haddow, J. E., Knight, G. J., Palomaki, G. E., & Canick, J. A. (1988) · BMJ · doi:10.1136/bmj.297.6653.883 · Cited by 966
Self-citationCUCKLE, H. S., WALD, N. J., & THOMPSON, S. G. (1987) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1987.tb03115.x · Cited by 604
Self-citationPandya, P. P., Snijders, R. J. M., Johnson, S. P., de Lourdes Brizot, M., & Nicolaids, K. H. (1995) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1995.tb10902.x · Cited by 411
Antenatal Screening for Down's Syndrome
Wald, N. J., Kennard, A., Hackshaw, A., & McGuire, A. (1997) · Journal of Medical Screening · doi:10.1177/096914139700400402 · Cited by 406
Self-citationScreening of Maternal Serum for Fetal Down's Syndrome in the First Trimester
Haddow, J. E., Palomaki, G. E., Knight, G. J., Williams, J., Miller, W. A., & Johnson, A. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804023381404 · Cited by 232
PRENATAL SCREENING FOR DOWN'S SYNDROME USING INHIBIN-A AS A SERUM MARKER
WALD, N. J., DENSEM, J. W., GEORGE, L., MUTTUKRISHNA, S., & KNIGHT, P. G. (1996) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199602)16:2<143::aid-pd825>3.0.co;2-f · Cited by 231
Self-citationWALD, N. J., CUCKLE, H. S., DENSEM, J. W., KENNARD, A., & SMITH, D. (1992) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1992.tb14474.x · Cited by 200
Self-citationSerum screening for Down's syndrome between 8 and 14 weeks of pregnancy
Wald, N. J., George, L., Smith, D., Densem, J. W., Pettersonm, K., & on behalf of the International Prenatal Screening Research Group (1996) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1996.tb09765.x · Cited by 199
Self-citationModel‐based screening by risk with application to down's syndrome
Royston, P., & Thompson, S. G. (1992) · Statistics in Medicine · doi:10.1002/sim.4780110211 · Cited by 173
Letter. Correct estimation of parameters for ultrasound nuchal translucency screening
Nicolaides, K. H., Snijders, R. J. M., & Cuckle, H. (1998) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199805)18:5<519::aid-pd398>3.0.co;2-u · Cited by 162
Correct estimation of parameters for ultrasound nuchal translucency screening.
Nicolaides, K. H., Snijders, R. J. M., & Cuckle, H. (1998) · PubMed · Cited by 148
Brizot, M. L., Snijders, R. J. M., Butler, J., Bersinger, N. A., & Nicolaides, K. H. (1995) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1995.tb09065.x · Cited by 92
Noble, P. L., Abraha, H. D., Snijders, R. J. M., Sherwood, R. A., & Nicolaides, K. H. (1995) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1995.06060390.x · Cited by 53
Assessment of fetal nuchal translucency test for Down's syndrome
Neilson, J. P. (1997) · The Lancet · doi:10.1016/s0140-6736(05)62562-7 · Cited by 35
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
First-Trimester or Second-Trimester Screening, or Both, for Down's Syndrome
Malone, F. D., Canick, J. A., Ball, R. H., Nyberg, D. A., Comstock, C. H., Bukowski, R., Berkowitz, R. L., Gross, S. J., Dugoff, L., Craigo, S. D., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043693 · Cited by 1,081
Self-citationPalomaki, G. E., Kloza, E. M., Lambert-Messerlian, G. M., Haddow, J. E., Neveux, L. M., Ehrich, M., van den Boom, D., Bombard, A. T., Deciu, C., Grody, W. W., et al. (2011) · Genetics in Medicine · doi:10.1097/gim.0b013e3182368a0e · Cited by 939
Chromosome Abnormalities and Genetic Counseling
Gardner, R. J. M., Sutherland, G. R., & Shaffer, L. G. (2011) · Oxford University Press eBooks · doi:10.1093/med/9780195375336.001.0001 · Cited by 857
Screening for fetal aneuploidies at 11 to 13 weeks
Nicolaides, K. H. (2011) · Prenatal Diagnosis · doi:10.1002/pd.2637 · Cited by 642
Metadata
- Authors
- Wald, N. J., Watt, H. C., & Hackshaw, A. K.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1999-08-12
- Volume
- 341
- Issue
- 7
- Pages
- 461-467
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1967882786
- Cited by
- 530
- References
- 15
- FWCI
- 33.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.