Hepatic Iron Concentration and Total Body Iron Stores in Thalassemia Major
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND METHODS: We tested the usefulness of measuring the hepatic iron concentration to evaluate total body iron stores in patients who had been cured of thalassemia major by bone marrow transplantation and who were undergoing phlebotomy treatment to remove excess iron. RESULTS: We began treatment with phlebotomy a mean (+/-SD) of 4.3+/-2.7 years after transplantation in 48 patients without hepatic cirrhosis. In the group of 25 patients with liver-biopsy samples that were at least 1.0 mg in dry weight, there was a significant correlation between the decrease in the hepatic iron concentration and total body iron stores (r=0.98, P<0.001). Assuming that the hepatic iron concentration is reduced to zero with complete removal of body iron stores during phlebotomy, the amount of total body iron stores (in milligrams per kilogram of body weight) is equivalent to 10.6 times the hepatic iron concentration (in milligrams per gram of liver, dry weight). With the use of this equation, we could reliably estimate total body iron stores as high as 250 mg per kilogram of body weight, with a standard error of less than 7.9. CONCLUSIONS: The hepatic iron concentration is a reliable indicator of total body iron stores in patients with thalassemia major. In patients with transfusion-related iron overload, repeated determinations of the hepatic iron concentration can provide a quantitative means of measuring the long-term iron balance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCullagh, P., & Nelder, J. A. (1989) · doi:10.1007/978-1-4899-3242-6 · Cited by 16,836
Generalized Linear Models (2nd ed.).
Therneau, T. M., McCullagh, P., & Nelder, J. A. (1993) · Journal of the American Statistical Association · doi:10.2307/2290358 · Cited by 4,907
The Relationship Between Variable Selection and Data Agumentation and a Method for Prediction
Allen, D. M. (1974) · Technometrics · doi:10.1080/00401706.1974.10489157 · Cited by 1,469
A Predictive Approach to Model Selection
Geisser, S., & Eddy, W. F. (1979) · Journal of the American Statistical Association · doi:10.1080/01621459.1979.10481632 · Cited by 988
Hallberg, L., Hôgdahl, A., Nilsson, L., & Rybo, G. (1966) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.3109/00016346609158455 · Cited by 966
Brittenham, G. M., Griffith, P. M., Nienhuis, A. W., McLaren, C. E., Young, N. S., Tucker, E. E., Allen, C. J., Farrell, D. E., & Harris, J. W. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409013310902 · Cited by 829
Self-citationApplied Linear Regression (2nd ed.).
Miller, R. B., & Weisberg, S. (1986) · Journal of the American Statistical Association · doi:10.2307/2289035 · Cited by 562
Magnetic-Susceptibility Measurement of Human Iron Stores
Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W. A., Tripp, J. H., & Bellon, E. M. (1982) · New England Journal of Medicine · doi:10.1056/nejm198212303072703 · Cited by 367
Self-citationBarry, M., Flynn, D. M., Letsky, E. A., & Risdon, R. A. (1974) · BMJ · doi:10.1136/bmj.2.5909.16 · Cited by 326
Phlebotomy to Reduce Iron Overload in Patients Cured of Thalassemia by Bone Marrow Transplantation
Angelucci, E., Muretto, P., Lucarelli, G., Ripalti, M., BARONCIANI, D., Erer, B., GALIMBERTI, M., Giardini, C., Gaziev, J., Polchi, P., et al. (1997) · Blood · doi:10.1182/blood.v90.3.994 · Cited by 154
Self-citationHepatic Iron Concentration: Noninvasive Estimation by Means of MR Imaging Techniques
Bonkovsky, H. L., Rubin, R. B., Cable, E. E., Davidoff, A., Rijcken, T. H. P., & Stark, D. D. (1999) · Radiology · doi:10.1148/radiology.212.1.r99jl35227 · Cited by 150
Angelucci, E., BARONCIANI, D., Lucarelli, G., Baldassarri, M., GALIMBERTI, M., Giardini, C., Martinelli, F., Polchi, P., Polizzi, V., Ripalti, M., et al. (1995) · British Journal of Haematology · doi:10.1111/j.1365-2141.1995.tb08412.x · Cited by 133
Self-citationLiver iron concentration, stainable iron, and total body storage iron
Barry, M. (1974) · Gut · doi:10.1136/gut.15.5.411 · Cited by 89
The British Nutrition Foundation (1995) · Springer eBooks · doi:10.1007/978-94-011-0585-9_5 · Cited by 81
Limitations of Magnetic Resonance Imaging in Measurement of Hepatic Iron
Angelucci, E., Giovagnoni, A., Valeri, G., Paci, E., Ripalti, M., Muretto, P., McLaren, C. E., Brittenham, G. M., & Lucarelli, G. (1997) · Blood · doi:10.1182/blood.v90.12.4736 · Cited by 79
Self-citationDistribution of storage iron as body stores expand in patients with hemochromatosis.
Valberg, L., Jb, S., Pn, M., We, C., & Ludwig, J. (1975) · PubMed · Cited by 67
Magnetic Resonance Imaging Measurement of Volume Magnetic Susceptibility Using a Boundary Condition
Wang, Z., Li, S., & Haselgrove, J. C. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1873 · Cited by 56
Cited by
Galanello, R., & Origa, R. (2010) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-5-11 · Cited by 1,466
Wood, J. C., Enriquez, C., Ghugre, N., Tyzka, J. M., Carson, S., Nelson, M. D., & Coates, T. D. (2005) · Blood · doi:10.1182/blood-2004-10-3982 · Cited by 1,045
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance
St. Pierre, T. G., Clark, P. R., Chua-anusorn, W., Fleming, A. J., Jeffrey, G. P., Olynyk, J. K., Pootrakul, P., Robins, E., & Lindeman, R. (2005) · Blood · doi:10.1182/blood-2004-01-0177 · Cited by 909
Taher, A. T., Weatherall, D. J., & Cappellini, M. D. (2018) · The Lancet · doi:10.1016/s0140-6736(17)31822-6 · Cited by 807
Metadata
- Authors
- Angelucci, E., Brittenham, G. M., McLaren, C. E., Ripalti, M., Baronciani, D., Giardini, C., Galimberti, M., Polchi, P., & Lucarelli, G.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2000-08-03
- Volume
- 343
- Issue
- 5
- Pages
- 327-331
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2318456157
- Cited by
- 607
- References
- 17
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.