The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abnormal Subendocardial Perfusion in Cardiac Syndrome X Detected by Cardiovascular Magnetic Resonance Imaging
Abstract
BACKGROUND: In cardiac syndrome X (a syndrome characterized by typical angina, abnormal exercise-test results, and normal coronary arteries), conventional investigations have not found that chest pain is due to myocardial ischemia. Magnetic resonance techniques have higher resolution and therefore may be more sensitive. METHODS: We performed myocardial-perfusion cardiovascular magnetic resonance imaging in 20 patients with syndrome X and 10 matched controls, both at rest and during an infusion of adenosine. Quantitative perfusion analysis was performed by using the normalized upslope of myocardial signal enhancement to derive the myocardial perfusion index and the myocardial-perfusion reserve index (defined as the ratio of the myocardial perfusion index during stress to the index at rest). RESULTS: In the controls, the myocardial perfusion index increased in both myocardial layers with adenosine (in the subendocardium, from a mean [+/-SD] of 0.12+/-0.03 to 0.16+/-0.03 [P=0.02]; in the subepicardium, from 0.11+/-0.02 to 0.17+/-0.05 [P=0.002]); in patients with syndrome X, the myocardial perfusion index did not change significantly in the subendocardium (0.13+/-0.02 vs. 0.14+/-0.03, P=0.11; P=0.09 as compared with controls) but increased in the subepicardium (from 0.11+/-0.02 to 0.20+/-0.04, P<0.001; P=0.11 for the comparison with controls). Adenosine provoked chest pain in 95 percent of patients with syndrome X and 40 percent of controls (P<0.001). CONCLUSIONS: In patients with syndrome X, cardiovascular magnetic resonance imaging demonstrates subendocardial hypoperfusion during the intravenous administration of adenosine, which is associated with intense chest pain. These data support the notion that the chest pain may have an ischemic cause.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schwitter, J., Nanz, D., Kneifel, S., Bertschinger, K., Büchi, M., Knüsel, P. R., Marincek, B., Lüscher, T. F., & von Schulthess, G. K. (2001) · Circulation · doi:10.1161/01.cir.103.18.2230 · Cited by 663
“Microvascular angina” as a cause of chest pain with angiographically normal coronary arteries
Cannon, R. O., & Epstein, S. E. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91180-0 · Cited by 580
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Cardiac syndrome X: Clinical characteristics and left ventricular function
Kaski, J. C., Collins, P., Nihoyannopoulos, P., Maseri, A., Poole-Wilson, P. A., & Rosano, G. M. C. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00507-m · Cited by 482
Self-citationKemp, H. G., Kronmal, R. A., Vlietstra, R. E., & Frye, R. L. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80456-9 · Cited by 464
Opherk, D., Zebe, H., Weihe, E., Mall, G., Dürr, C., Gravert, B., Mehmel, H. C., Schwarz, F., & Kübler, W. (1981) · Circulation · doi:10.1161/01.cir.63.4.817 · Cited by 440
Left ventricular function in patients with the anginal syndrome and normal coronary arteriograms
Kemp, H. G. (1973) · The American Journal of Cardiology · doi:10.1016/s0002-9149(73)80150-x · Cited by 433
Mechanisms of angina pectoris in syndrome X
Maseri, A., Crea, F., Kaski, J. C., & Crake, T. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80122-6 · Cited by 424
Angina caused by reduced vasodilator reserve of the small coronary arteries
Cannon, R. O., Watson, R. M., Rosing, D. R., & Epstein, S. E. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80037-0 · Cited by 409
Camici, P. G., Marraccini, P., Lorenzoni, R., Buzzigoli, G., Pecori, N., Perissinotto, A., Ferrannini, E., L'Abbate, A., & Marzilli, M. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90632-j · Cited by 214
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Schulz-Menger, J., Bluemke, D. A., Bremerich, J., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Kim, R. J., von Knobelsdorff-Brenkenhoff, F., Kramer, C. M., Pennell, D. J., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-35 · Cited by 2,097
Self-citationAnderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181940 · Cited by 1,853
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.013 · Cited by 1,510
Endothelial Function: Cardiac Events
Lerman, A., & Zeiher, A. M. (2005) · Circulation · doi:10.1161/01.cir.0000153339.27064.14 · Cited by 1,096
Metadata
- Authors
- Panting, J. R., Gatehouse, P. D., Yang, G.-Z., Grothues, F., Firmin, D. N., Collins, P., & Pennell, D. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2002-06-20
- Volume
- 346
- Issue
- 25
- Pages
- 1948-1953
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1971926213
- Cited by
- 767
- References
- 21
- FWCI
- 31.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Abnormal Subendocardial Perfusion in Cardiac Syndrome X Detected by Cardiovascular Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1056/nejmoa012369
- The paper
- Panting, J. R., Gatehouse, P. D., Yang, G.-Z., Grothues, F., Firmin, D. N., Collins, P., & Pennell, D. J. (2002). Abnormal Subendocardial Perfusion in Cardiac Syndrome X Detected by Cardiovascular Magnetic Resonance Imaging. New England Journal of Medicine. https://doi.org/10.1056/nejmoa012369
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.