The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
A Comparison of On-Pump and Off-Pump Coronary Bypass Surgery in Low-Risk Patients
Open accessAbstract
BACKGROUND: The performance of coronary bypass surgery without cardiopulmonary bypass ("off pump") may reduce perioperative morbidity and costs, but it is uncertain whether the outcome is similar to that involving the use of cardiopulmonary bypass ("on pump"). METHODS: In a multicenter, randomized trial, we randomly assigned 139 patients with predominantly single- or double-vessel coronary disease to on-pump surgery and 142 to off-pump surgery. Cardiac outcome and cost effectiveness were determined one year after surgery. The uncertainty surrounding the cost-effectiveness ratio (cost differences per quality-adjusted year of life gained) was addressed by bootstrapping. RESULTS: At one year, the rate of freedom from death, stroke, myocardial infarction, and coronary reintervention was 90.6 percent after on-pump surgery and 88.0 percent after off-pump surgery (absolute difference, 2.6 percent; 95 percent confidence interval, - 4.6 to 9.8). Graft patency in a randomized subgroup of patients was 93 percent after on-pump surgery and 91 percent after off-pump surgery (absolute difference, 2.0 percent; 95 percent confidence interval, - 6.5 to 10.4). On-pump surgery was associated with $1,839 in additional direct costs per patient ($14,908 vs. $13,069--a difference of 14.1 percent) and an increase in quality-adjusted years of life of 0.83 as compared with 0.82 (difference, 0.01 year; 95 percent confidence interval, - 0.03 to 0.04). Off-pump surgery was more cost effective than on-pump surgery in 95 percent of bootstrap estimates. CONCLUSIONS: In low-risk patients, there was no difference in cardiac outcome at one year between those who underwent on-pump bypass surgery and those who underwent off-pump surgery. Off-pump surgery was more cost effective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
EuroQol: a new facility for the measurement of health-related quality of life
(1990) · Health Policy · doi:10.1016/0168-8510(90)90421-9 · Cited by 15,736
Interobserver agreement for the assessment of handicap in stroke patients
van Swieten, J. C., Koudstaal, P. J., Visser, M. C., Schouten, H. J., & van Gijn, J. (1988) · Stroke · doi:10.1161/01.str.19.5.604 · Cited by 6,512
Yusuf, S., Zucker, D., Passamani, E., Peduzzi, P., Takaro, T., Fisher, L. D., Kennedy, J. W., Davis, K., Killip, T., Norris, R., et al. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91963-1 · Cited by 2,134
Adverse Cerebral Outcomes after Coronary Bypass Surgery
Roach, G. W., Kanchuger, M., Mangano, C. M., Newman, M., Nussmeier, N., Wolman, R., Aggarwal, A., Marschall, K., Graham, S. H., Ley, C., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352501 · Cited by 1,860
Letter: Grading of angina pectoris.
Campeau, L. (1976) · Circulation · doi:10.1161/circ.54.3.947585 · Cited by 1,601
Unstable angina. A classification.
Braunwald, E. (1989) · Circulation · doi:10.1161/01.cir.80.2.410 · Cited by 1,366
Comparison of Coronary-Artery Bypass Surgery and Stenting for the Treatment of Multivessel Disease
Serruys, P. W., Unger, F., Sousa, J. E., Jatene, A., Bonnier, H. J. R. M., Schönberger, J. P. A. M., Buller, N., Bonser, R., van den Brand, M. J. B., van Herwerden, L. A., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104123441502 · Cited by 1,114
Variations in population health status: results from a United Kingdom national questionnaire survey
Kind, P., Dolan, P., Gudex, C., & Williams, A. (1998) · BMJ · doi:10.1136/bmj.316.7133.736 · Cited by 1,059
Ferguson, T. B., Hammill, B. G., Peterson, E. D., DeLong, E. R., & Grover, F. L. (2002) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)03339-2 · Cited by 652
Angelini, G. D., Taylor, F. C., Reeves, B. C., & Ascione, R. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08216-8 · Cited by 566
Myonecrosis After Revascularization Procedures
Califf, R. M., Abdelmeguid, A. E., Kuntz, R. E., Popma, J. J., Davidson, C. J., Cohen, E. A., Kleiman, N. S., Mahaffey, K. W., Topol, E. J., Pepine, C. J., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00506-8 · Cited by 552
Early Outcome After Off-Pump Versus On-Pump Coronary Bypass Surgery: Results From a Randomized Study
van Dijk, D., Nierich, A. P., Jansen, E. W. L., Nathoe, H. M., Suyker, W. J. L., Diephuis, J. C., van Boven, W.-J., Borst, C., Buskens, E., Grobbee, D. E., et al. (2001) · Circulation · doi:10.1161/hc4001.097036 · Cited by 515
Self-citationVan Dijk, D. (2002) · JAMA · doi:10.1001/jama.287.11.1405 · Cited by 514
Self-citationDavies, R. F., Goldberg, A. D., Forman, S., Pepine, C. J., Knatterud, G. L., Geller, N., Sopko, G., Pratt, C., Deanfield, J., & Conti, C. R. (1997) · Circulation · doi:10.1161/01.cir.95.8.2037 · Cited by 461
Off-pump coronary artery bypass grafting decreases risk-adjusted mortality and morbidity
Cleveland, J. C., Shroyer, A. L. W., Chen, A. Y., Peterson, E., & Grover, F. L. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)03006-5 · Cited by 453
Prognostic Implication of Creatine Kinase Elevation Following Elective Coronary Artery Interventions
Kong, T. Q. (1997) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1997.03540300029029 · Cited by 283
Economic outcome of off-pump coronary artery bypass surgery: a prospective randomized study
Ascione, R., Lloyd, C. T., Underwood, M. J., Lotto, A. A., Pitsis, A. A., & Angelini, G. D. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)01123-6 · Cited by 197
Costa, M. A., Carere, R. G., Lichtenstein, S. V., Foley, D. P., de Valk, V., Lindenboom, W., Roose, P. C. H., van Geldorp, T. R., Macaya, C., Castanon, J. L., et al. (2001) · Circulation · doi:10.1161/hc4701.099789 · Cited by 180
Is there a kink in consumers' threshold value for cost‐effectiveness in health care?
OʼBrien, B. J., Герцен, К. А., Willan, A. R., & Faulkner, A. (2002) · Health Economics · doi:10.1002/hec.655 · Cited by 155
de Boer, M. J., van Hout, B. A., Liem, A., Suryapranata, H., Hoorntje, J. C. A., & Zijlstra, F. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80238-0 · Cited by 91
Minimally Invasive Coronary Artery Bypass Grafting
Borst, C., & Gründeman, P. F. (1999) · Circulation · doi:10.1161/01.cir.99.11.1400 · Cited by 82
Self-citationCowper, P. A., Peterson, E. D., DeLong, E. R., Jollis, J. G., Muhlbaier, L. H., & Mark, D. B. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00243-x · Cited by 44
van Dijk, D., Nierich, A. P., Eefting, F. D., Buskens, E., Nathoe, H. M., Jansen, E. W. L., Borst, C., Knape, J. T. A., Bredée, J. J., de Medina, E. O. R., et al. (2000) · Controlled Clinical Trials · doi:10.1016/s0197-2456(00)00103-3 · Cited by 39
Self-citation
Cited by
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.009 · Cited by 820
Writing Committee Members, Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823c074e · Cited by 781
Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days
Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Paolasso, E., Straka, Z., Piegas, L. S., Akar, A. R., Jain, A. R., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200388 · Cited by 707
Metadata
- Authors
- Nathoe, H. M., van Dijk, D., Jansen, E. W. L., Suyker, W. J. L., Diephuis, J. C., van Boven, W.-J., de la Rivière, A. B., Borst, C., Kalkman, C. J., Grobbee, D. E., Buskens, E., & de Jaegere, P. P. T.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2003-01-30
- Volume
- 348
- Issue
- 5
- Pages
- 394-402
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2023325651
- Cited by
- 402
- References
- 25
- FWCI
- 45.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.