The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization
Abstract
BACKGROUND: Sirolimus-eluting stents and paclitaxel-eluting stents, as compared with bare-metal stents, reduce the risk of restenosis. It is unclear whether there are differences in safety and efficacy between the two types of drug-eluting stents. METHODS: We conducted a randomized, controlled, single-blind trial comparing sirolimus-eluting stents with paclitaxel-eluting stents in 1012 patients undergoing percutaneous coronary intervention. The primary end point was a composite of major adverse cardiac events (death from cardiac causes, myocardial infarction, and ischemia-driven revascularization of the target lesion) by nine months. Follow-up angiography was completed in 540 of 1012 patients (53.4 percent). RESULTS: The two groups had similar baseline clinical and angiographic characteristics. The rate of major adverse cardiac events at nine months was 6.2 percent in the sirolimus-stent group and 10.8 percent in the paclitaxel-stent group (hazard ratio, 0.56; 95 percent confidence interval, 0.36 to 0.86; P=0.009). The difference was driven by a lower rate of target-lesion revascularization in the sirolimus-stent group than in the paclitaxel-stent group (4.8 percent vs. 8.3 percent; hazard ratio, 0.56; 95 percent confidence interval, 0.34 to 0.93; P=0.03). Rates of death from cardiac causes were 0.6 percent in the sirolimus-stent group and 1.6 percent in the paclitaxel-stent group (P=0.15); the rates of myocardial infarction were 2.8 percent and 3.5 percent, respectively (P=0.49); and the rates of angiographic restenosis were 6.6 percent and 11.7 percent, respectively (P=0.02). CONCLUSIONS: As compared with paclitaxel-eluting stents, the use of sirolimus-eluting stents results in fewer major adverse cardiac events, primarily by decreasing the rates of clinical and angiographic restenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Assessing the quality of controlled clinical trials
Jüni, P., Altman, D. G., & Egger, M. (2001) · BMJ · doi:10.1136/bmj.323.7303.42 · Cited by 3,309
Self-citationA Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Colombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
Grube, E., Silber, S., Hauptmann, K. E., Mueller, R., Buellesfeld, L., Gerckens, U., & Russell, M. E. (2003) · Circulation · doi:10.1161/01.cir.0000047700.58683.a1 · Cited by 865
Cited by
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Self-citationPercutaneous Coronary Intervention of Functionally Nonsignificant Stenosis
Pijls, N. H. J., van Schaardenburgh, P., Manoharan, G., Boersma, E., Bech, J.-W., van’t Veer, M., Bär, F., Hoorntje, J., Koolen, J., Wijns, W., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.087 · Cited by 1,516
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Self-citationKing, S. B., Smith, S. C., Hirshfeld, J. W., Jacobs, A. K., Morrison, D. A., Williams, D. O., 2005 WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.188208 · Cited by 1,014
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Cook, S., Wenaweser, P., Togni, M., Billinger, M., Morger, C., Seiler, C., Vogel, R., Hess, O., Meier, B., & Windecker, S. (2007) · Circulation · doi:10.1161/circulationaha.106.658237 · Cited by 839
Self-citationCamenzind, E., Steg, P. G., & Wijns, W. (2007) · Circulation · doi:10.1161/circulationaha.106.666800 · Cited by 818
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Drug-Eluting Coronary-Artery Stents
Stefanini, G. G., & Holmes, D. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1210816 · Cited by 728
Kedhi, E., Joesoef, K. S., McFadden, E., Wassing, J., van Mieghem, C., Goedhart, D., & Smits, P. C. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62127-9 · Cited by 687
Comparison of Zotarolimus-Eluting and Everolimus-Eluting Coronary Stents
Serruys, P. W., Silber, S., Garg, S., van Geuns, R. J., Richardt, G., Buszman, P. E., Kelbæk, H., van Boven, A. J., Hofma, S. H., Linke, A., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1004130 · Cited by 670
Self-citationWindecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
Self-citationGwon, H.-C., Hahn, J.-Y., Park, K. W., Song, Y. B., Chae, I.-H., Lim, D.-S., Han, K.-R., Choi, J.-H., Choi, S.-H., Kang, H.-J., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.059022 · Cited by 614
2007 Focused Update of the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
King, S. B., Smith, S. C., Hirshfeld, J. W., Morrison, D. A., Williams, D. O., & Jacobs, A. K. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.002 · Cited by 612
Stone, G. W. (2008) · JAMA · doi:10.1001/jama.299.16.1903 · Cited by 582
Bangalore, S., Kumar, S., Fusaro, M., Amoroso, N., Attubato, M. J., Feit, F., Bhatt, D. L., & Slater, J. (2012) · Circulation · doi:10.1161/circulationaha.112.097014 · Cited by 574
Sirolimus-Eluting versus Uncoated Stents in Acute Myocardial Infarction
Spaulding, C., Henry, P., Teiger, E., Beatt, K., Bramucci, E., Carrié, D., Slama, M. S., Merkely, B., Erglis, A., Margheri, M., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa062006 · Cited by 564
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Cook, S., Ladich, E., Nakazawa, G., Eshtehardi, P., Neidhart, M., Vogel, R., Togni, M., Wenaweser, P., Billinger, M., Seiler, C., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.854398 · Cited by 480
Self-citationDzau, V. J., Antman, E. M., Black, H. R., Hayes, D. L., Manson, J. E., Plutzky, J., Popma, J. J., & Stevenson, W. (2006) · Circulation · doi:10.1161/circulationaha.106.655688 · Cited by 437
Jagur‐Grodzinski, J. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.729 · Cited by 394
Schömig, A., Dibra, A., Windecker, S., Mehilli, J., Suárez de Lezo, J., Kaiser, C., Park, S.-J., Goy, J.-J., Lee, J.-H., Di Lorenzo, E., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.047 · Cited by 359
Self-citationEnoxaparin versus Unfractionated Heparin in Elective Percutaneous Coronary Intervention
Montalescot, G., White, H. D., Gallo, R., Cohen, M., Steg, P. G., Aylward, P. E. G., Bode, C., Chiariello, M., King, S. B., Harrington, R. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052711 · Cited by 359
Kandzari, D. E., Leon, M. B., Popma, J. J., Fitzgerald, P. J., O’Shaughnessy, C., Ball, M. W., Turco, M., Applegate, R. J., Gurbel, P. A., Midei, M. G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.035 · Cited by 347
Kaiser, C., Brunner-La Rocca, H. P., Buser, P. T., Bonetti, P. O., Osswald, S., Linka, A., Bernheim, A., Zutter, A., Zellweger, M., Grize, L., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67221-2 · Cited by 342
Kastrati, A., Dibra, A., Mehilli, J., Mayer, S., Pinieck, S., Pache, J., Dirschinger, J., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.601823 · Cited by 312
Nakazawa, G., Finn, A. V., Vorpahl, M., Ladich, E. R., Kolodgie, F. D., & Virmani, R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.066 · Cited by 299
Kastrati, A., Dibra, A., Eberle, S., Mehilli, J., Suárez de Lezo, J., Goy, J.-J., Ulm, K., & Schömig, A. (2005) · JAMA · doi:10.1001/jama.294.7.819 · Cited by 282
Drug-Eluting versus Bare-Metal Stents in Large Coronary Arteries
Kaiser, C., Galatius, S., Erne, P., Eberli, F., Alber, H., Rickli, H., Pedrazzini, G., Hornig, B., Bertel, O., Bonetti, P., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1009406 · Cited by 267
Self-citationRibichini, F., Tomai, F., De Luca, G., Boccuzzi, G., Presbitero, P., Pesarini, G., Ferrero, V., Ghini, A. S., Abukaresh, R., Aurigemma, C., et al. (2011) · The American Journal of Medicine · doi:10.1016/j.amjmed.2010.11.027 · Cited by 31
Metadata
- Authors
- Windecker, S., Remondino, A., Eberli, F. R., Jüni, P., Räber, L., Wenaweser, P., Togni, M., Billinger, M., Tüller, D., Seiler, C., Roffi, M., Corti, R., Sütsch, G., Maier, W., Lüscher, T., Hess, O. M., Egger, M., & Meier, B.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2005-08-18
- Volume
- 353
- Issue
- 7
- Pages
- 653-662
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1997207240
- Cited by
- 593
- References
- 19
- FWCI
- 76.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.