Effect of Home Testing of International Normalized Ratio on Clinical Events

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. METHODS: We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). RESULTS: The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). CONCLUSIONS: As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin therapy. (Funded by the Department of Veterans Affairs Cooperative Studies Program; ClinicalTrials.gov number, NCT00032591.).

Overview

Integrity signals

Registry

Crossref · 10.1056/nejmoa1002617

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 266

Metadata

Authors
Matchar, D. B., Jacobson, A., Dolor, R., Edson, R., Uyeda, L., Phibbs, C. S., Vertrees, J. E., Shih, M.-C., Holodniy, M., & Lavori, P.
Affiliations
Durham VA Medical Center (US)
Venue
New England Journal of Medicine
Published
2010-10-21
Volume
363
Issue
17
Pages
1608-1620
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2039217072
Cited by
266
References
23
Citations by year
2026: 7 · 2025: 4 · 2024: 4 · 2023: 8 · 2022: 4 · 2021: 14 · 2020: 11 · 2019: 17 · 2018: 11 · 2017: 11 · 2016: 28 · 2015: 10 · 2014: 16 · 2013: 38 · 2012: 39
FWCI
26.34
Type
journal article
Language
en
Open access
closed
Locations
  • New England Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • National University of Singapore (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
Keywords
warfarin, international normalized ratio, home self-testing, point-of-care testing, anticoagulation management, atrial fibrillation, mechanical heart valves, stroke prevention, major bleeding, patient satisfaction, quality of life, INR control
MeSH terms
Aged, Anticoagulants, Atrial Fibrillation, Female, Follow-Up Studies, Heart Valve Prosthesis, Hemorrhage, Humans, Male, Middle Aged, Mortality, Myocardial Infarction, Prospective Studies, Self Care, Thrombosis, Warfarin, Drug Monitoring, International Normalized Ratio, Stroke, Kaplan-Meier Estimate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.