Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 822

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Cryoablation or Drug Therapy for Initial Treatment of Atrial Fibrillation

Open access
Andrade, Jason G., Wells, George A., Deyell, Marc W., Bennett, Matthew, Essebag, Vidal, Champagne, Jean, Roux, Jean-Francois, Yung, Derek, Skanes, Allan, Khaykin, Yaariv, Morillo, Carlos, Jolly, Umjeet, Novak, Paul, Lockwood, Evan, Amit, Guy, Angaran, Paul, Sapp, John, Wardell, Stephan, Lauck, Sandra, Macle, Laurent, Verma, Atul·2021·New England Journal of Medicine

Abstract

BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa2029980

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 822

Metadata

Authors
Andrade, J. G., Wells, G. A., Deyell, M. W., Bennett, M., Essebag, V., Champagne, J., Roux, J.-F., Yung, D., Skanes, A., Khaykin, Y., Morillo, C., Jolly, U., Novak, P., Lockwood, E., Amit, G., Angaran, P., Sapp, J., Wardell, S., Lauck, S., Macle, L., & Verma, A.
Venue
New England Journal of Medicine
Published
2021-01-28
Volume
384
Issue
4
Pages
305-315
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W3101635021
Cited by
822
References
31
FWCI
60.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cryoablation or Drug Therapy for Initial Treatment of Atrial Fibrillation. https://app.cochat.ai/papers/10.1056/nejmoa2029980
The paper
Andrade, J. G., Wells, G. A., Deyell, M. W., Bennett, M., Essebag, V., Champagne, J., Roux, J.-F., Yung, D., Skanes, A., Khaykin, Y., Morillo, C., Jolly, U., Novak, P., Lockwood, E., Amit, G., Angaran, P., Sapp, J., Wardell, S., Lauck, S., . . . Verma, A. (2021). Cryoablation or Drug Therapy for Initial Treatment of Atrial Fibrillation. New England Journal of Medicine. https://doi.org/10.1056/nejmoa2029980

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.