The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Cryoablation or Drug Therapy for Initial Treatment of Atrial Fibrillation
Open accessAbstract
BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationJanuary, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000665 · Cited by 2,744
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Early Rhythm-Control Therapy in Patients with Atrial Fibrillation
Kirchhof, P., Camm, A. J., Goette, A., Brandes, A., Eckardt, L., Elvan, A., Fetsch, T., van Gelder, I. C., Haase, D., Haegeli, L. M., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2019422 · Cited by 2,190
Andrade, J., Khairy, P., Dobrev, D., & Nattel, S. (2014) · Circulation Research · doi:10.1161/circresaha.114.303211 · Cited by 1,187
Self-citationWilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
Self-citationAmiodarone to Prevent Recurrence of Atrial Fibrillation
Roy, D., Talajic, M., Dorian, P., Connolly, S., Eisenberg, M. J., Green, M., Kus, T., Lambert, J., Dubuc, M., Gagné, P., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003303421302 · Cited by 1,143
Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation
Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., Dubuc, M., Reddy, V., Nelson, L., Holcomb, R. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.064 · Cited by 899
Self-citationRadiofrequency ablation as initial therapy in paroxysmal atrial fibrillation
Cosedis Nielsen, J., Johannessen, A., Raatikainen, P., Hindricks, G., Walfridsson, H., Kongstad, O., Pehrson, S., Englund, A., Hartikainen, J., Mortensen, L. S., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113566 · Cited by 720
Morillo, C. A., Verma, A., Connolly, S. J., Kuck, K. H., Nair, G. M., Champagne, J., Sterns, L. D., Beresh, H., Healey, J. S., Natale, A., et al. (2014) · JAMA · doi:10.1001/jama.2014.467 · Cited by 667
Self-citationAndrade, J. G., Champagne, J., Dubuc, M., Deyell, M. W., Verma, A., Macle, L., Leong-Sit, P., Novak, P., Badra-Verdu, M., Sapp, J., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.042622 · Cited by 570
Self-citationAndrade, J. G., Aguilar, M., Atzema, C., Bell, A., Cairns, J. A., Cheung, C. C., Cox, J. L., Dorian, P., Gladstone, D. J., Healey, J. S., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.09.001 · Cited by 562
Self-citationComparison of continuous versus intermittent monitoring of atrial arrhythmias
Ziegler, P. D., Koehler, J. L., & Mehra, R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.030 · Cited by 282
Early management of atrial fibrillation to prevent cardiovascular complications
Nattel, S., Guasch, E., Savelieva, I., Cosio, F. G., Valverde, I., Halperin, J. L., Conroy, J. M., Al-Khatib, S. M., Hess, P. L., Kirchhof, P., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu028 · Cited by 273
Macle, L., Khairy, P., Weerasooriya, R., Novak, P., Verma, A., Willems, S., Arentz, T., Deisenhofer, I., Veenhuyzen, G., Scavée, C., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60026-5 · Cited by 226
Self-citationPadfield, G. J., Steinberg, C., Swampillai, J., Qian, H., Connolly, S. J., Dorian, P., Green, M. S., Humphries, K. H., Klein, G. J., Sheldon, R., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.01.038 · Cited by 194
Sanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
Mechanisms and management of proarrhythmia
Roden, D. M. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00472-x · Cited by 127
Mittal, S., Rogers, J., Sarkar, S., Koehler, J. L., Warman, E. N., Tomson, T. T., & PASSMAN, R. S. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.05.010 · Cited by 95
Doyle, J. F., & Ho, K. M. (2009) · Mayo Clinic Proceedings · doi:10.4065/84.3.234 · Cited by 79
Herrera‐Siklody, C., Minners, J., Allgeier, M., Allgeier, H.-J., Jander, N., Weber, R., SCHIEBELING‐RÖMER, J., Neumann, F., Kalusche, D., & Arentz, T. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01524.x · Cited by 69
Schmidt, M. U., Daccarett, M., Marschang, H., Ritscher, G., Turschner, O., Brachmann, J., & Rittger, H. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01796.x · Cited by 61
Association of Atrial Fibrillation Episode Duration With Arrhythmia Recurrence Following Ablation
Andrade, J. G., Deyell, M. W., Verma, A., Macle, L., Champagne, J., Leong‐Sit, P., NOVAK, P. G., Badra‐Verdu, M., Sapp, J. L., Khairy, P., et al. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.8748 · Cited by 52
Self-citationNölker, G., Heintze, J., Gutleben, K., Muntean, B. G., Pütz, V., Yalda, A., Vogt, J., & Horstkotte, D. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01813.x · Cited by 50
Singh, S. N., Singh, B. N., Reda, D. J., Fye, C. L., Ezekowitz, M. D., Fletcher, R. D., Sharma, S. C., Atwood, J. E., Jacobson, A. K., Lewis, H. D., et al. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00671-4 · Cited by 49
Charitos, E. I., Ziegler, P., Stierle, U., Robinson, D., GRAF, B., Sievers, H., & Hanke, T. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12389 · Cited by 46
Quality of Life and Health Care Utilization in the CIRCA-DOSE Study
Andrade, J. G., Macle, L., Verma, A., Deyell, M. W., Champagne, J., Dubuc, M., Leong‐Sit, P., NOVAK, P. G., Roux, J.-F., Sapp, J. L., et al. (2020) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2020.04.017 · Cited by 46
Self-citationAndrade, J. G., Champagne, J., Deyell, M. W., Essebag, V., Lauck, S., Morillo, C. A., Sapp, J. L., Skanes, A. C., Theoret-Patrick, P., Wells, G. A., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.05.020 · Cited by 34
Self-citationSIMANTIRAKIS, E. N., Papakonstantinou, P. Ε., KANOUPAKIS, E. M., CHLOUVERAKIS, G. I., Tzeis, S. E., & Vardas, P. E. (2018) · Clinical Cardiology · doi:10.1002/clc.22904 · Cited by 32
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Self-citation
Metadata
- Authors
- Andrade, J. G., Wells, G. A., Deyell, M. W., Bennett, M., Essebag, V., Champagne, J., Roux, J.-F., Yung, D., Skanes, A., Khaykin, Y., Morillo, C., Jolly, U., Novak, P., Lockwood, E., Amit, G., Angaran, P., Sapp, J., Wardell, S., Lauck, S., Macle, L., & Verma, A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2021-01-28
- Volume
- 384
- Issue
- 4
- Pages
- 305-315
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W3101635021
- Cited by
- 822
- References
- 31
- FWCI
- 60.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.