Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 255

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Efficacy and Safety of an Extravascular Implantable Cardioverter–Defibrillator

Open access
Friedman, Paul, Murgatroyd, Francis, Boersma, Lucas V.A., Manlucu, Jaimie, O’Donnell, David, Knight, Bradley P., Clémenty, Nicolas, Leclercq, Christophe, Amin, Anish, Merkely, Béla P., Birgersdotter-Green, Ulrika M., Chan, Joseph Y.S., Biffi, Mauro, Knops, Reinoud E., Engel, Greg, Muñoz Carvajal, Ignacio, Epstein, Laurence M., Sagi, Venkata, Johansen, Jens B., Sterliński, Maciej, Steinwender, Clemens, Hounshell, Troy, Abben, Richard, Thompson, Amy E., Wiggenhorn, Christopher, Willey, Sarah, Crozier, Ian · 2022 · New England Journal of Medicine

Abstract

BACKGROUND: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS: A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS: In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa2206485

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 255

Metadata

Authors
Friedman, P., Murgatroyd, F., Boersma, L. V. A., Manlucu, J., O’Donnell, D., Knight, B. P., Clémenty, N., Leclercq, C., Amin, A., Merkely, B. P., Birgersdotter-Green, U. M., Chan, J. Y. S., Biffi, M., Knops, R. E., Engel, G., Muñoz Carvajal, I., Epstein, L. M., Sagi, V., Johansen, J. B., Sterliński, M., Steinwender, C., Hounshell, T., Abben, R., Thompson, A. E., Wiggenhorn, C., Willey, S., & Crozier, I.
Venue
New England Journal of Medicine
Published
2022-10-06
Volume
387
Issue
14
Pages
1292-1302
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W4293514805
Cited by
255
References
29
FWCI
29.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.