Left Atrial Appendage Closure after Ablation for Atrial Fibrillation
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BackgroundOral anticoagulation is recommended after ablation for atrial fibrillation among patients at high risk for stroke. Left atrial appendage closure is a mechanical alternative to anticoagulation, but data regarding its use after atrial fibrillation ablation are lacking. MethodsWe conducted an international randomized trial involving 1600 patients with atrial fibrillation who had an elevated score (≥2 in men and ≥3 in women) on the CHA2DS2-VASc scale (range, 0 to 9, with higher scores indicating a greater risk of stroke) and who underwent catheter ablation. Patients were randomly assigned in a 1:1 ratio to undergo left atrial appendage closure or receive oral anticoagulation. The primary safety end point, tested for superiority, was non–procedure-related major bleeding or clinically relevant nonmajor bleeding. The primary efficacy end point, tested for noninferiority, was a composite of death from any cause, stroke, or systemic embolism at 36 months. The secondary end point, tested for noninferiority, was major bleeding, including procedure-related bleeding, through 36 months. Research Summary Left Atrial Appendage Closure after Ablation for Atrial Fibrillation ResultsA total of 803 patients were assigned to undergo left atrial appendage closure, and 797 to receive anticoagulant therapy. The mean (±SD) age of the patients was 69.6±7.7 years, 34.1% of the patients were women, and the mean CHA2DS2-VASc score was 3.5±1.3. At 36 months, a primary safety end-point event had occurred in 65 patients (8.5%) in the left atrial appendage closure group (device group) and in 137 patients (18.1%) in the anticoagulation group (P<0.001 for superiority); a primary efficacy end-point event had occurred in 41 patients (5.3%) and 44 patients (5.8%), respectively (P<0.001 for noninferiority); and a secondary end-point event had occurred in 3.9% and 5.0% (P<0.001 for noninferiority). Complications related to the appendage closure device or procedure occurred in 23 patients. ConclusionsAmong patients who underwent catheter-based atrial fibrillation ablation, left atrial appendage closure was associated with a lower risk of non–procedure-related major or clinically relevant nonmajor bleeding than oral anticoagulation and was noninferior to oral anticoagulation with respect to a composite of death from any cause, stroke, or systemic embolism at 36 months. (Funded by Boston Scientific; OPTION ClinicalTrials.gov number, NCT03795298.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SCHULMAN, S., & KEARON, C. (2005) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01204.x · Cited by 5,009
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Holmes, D. R., Reddy, V. Y., Turi, Z. G., Doshi, S. K., Sievert, H., Buchbinder, M., Mullin, C. M., & Sick, P. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61343-x · Cited by 2,240
Self-citationHolmes, D. R., Kar, S., Price, M. J., Whisenant, B., Sievert, H., Doshi, S. K., Huber, K., & Reddy, V. Y. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.029 · Cited by 1,845
Self-citationPacker, D. L., Mark, D. B., Robb, R. A., Monahan, K. H., Bahnson, T. D., Poole, J. E., Noseworthy, P. A., Rosenberg, Y. D., Jeffries, N., Mitchell, L. B., et al. (2019) · JAMA · doi:10.1001/jama.2019.0693 · Cited by 1,503
Kaatz, S., Ahmad, D., Spyropoulos, A. C., & Schulman, S. (2015) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13140 · Cited by 1,419
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Osmancik, P., Herman, D., Neuzil, P., Hala, P., Taborsky, M., Kala, P., Poloczek, M., Stasek, J., Haman, L., Branny, M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.04.067 · Cited by 646
Self-citationLakkireddy, D., Thaler, D., Ellis, C. R., Swarup, V., Sondergaard, L., Carroll, J., Gold, M. R., Hermiller, J., Diener, H.-C., Schmidt, B., et al. (2021) · Circulation · doi:10.1161/circulationaha.121.057063 · Cited by 477
Self-citationApixaban for Stroke Prevention in Subclinical Atrial Fibrillation
Healey, J. S., Lopes, R. D., Granger, C. B., Alings, M., Rivard, L., McIntyre, W. F., Atar, D., Birnie, D. H., Boriani, G., Camm, A. J., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2310234 · Cited by 451
Self-citationKar, S., Doshi, S. K., Sadhu, A., Horton, R., Osorio, J., Ellis, C., Stone, J., Shah, M., Dukkipati, S. R., Adler, S., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.050117 · Cited by 414
Self-citationSteinberg, B. A., Hellkamp, A. S., Lokhnygina, Y., Patel, M. R., Breithardt, G., Hankey, G. J., Becker, R. C., Singer, D. E., Halperin, J. L., Hacke, W., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu359 · Cited by 356
Friberg, L., Tabrizi, F., & Englund, A. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw087 · Cited by 270
Al-Khatib, S. M., Thomas, L., Wallentin, L., Lopes, R. D., Gersh, B., Garcia, D., Ezekowitz, J., Alings, M., Yang, H., Alexander, J. H., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht135 · Cited by 194
Karasoy, D., Gislason, G. H., Hansen, J., Johannessen, A., Køber, L., Hvidtfeldt, M., Özcan, C., Torp-Pedersen, C., & Hansen, M. L. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu421 · Cited by 132
Noseworthy, P. A., Yao, X., Deshmukh, A. J., Van Houten, H., Sangaralingham, L. R., Siontis, K. C., Piccini, J. P., Asirvatham, S. J., Friedman, P. A., Packer, D. L., et al. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.002597 · Cited by 87
Kapadia, S. R., Yeh, R. W., Price, M. J., Piccini, J. P., Nair, D. G., Bansal, A., Hsu, J. C., Freeman, J. V., Christen, T., Allocco, D. J., et al. (2024) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.123.013750 · Cited by 80
Self-citationLandmesser, U., Skurk, C., Tzikas, A., Falk, V., Reddy, V. Y., & Windecker, S. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae398 · Cited by 79
Self-citationOutcomes and Anticoagulation Use After Catheter Ablation for Atrial Fibrillation
Freeman, J. V., Shrader, P., Pieper, K. S., Allen, L. A., Chan, P. S., Fonarow, G. C., Gersh, B. J., Kowey, P. R., Mahaffey, K. W., Naccarelli, G. V., et al. (2019) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007612 · Cited by 67
Burden of atrial high-rate episodes and risk of stroke: a systematic review
Uittenbogaart, S. B., Lucassen, W. A. M., van Etten‐Jamaludin, F. S., de Groot, J. R., & van Weert, H. C. P. M. (2017) · EP Europace · doi:10.1093/europace/eux356 · Cited by 63
Kapadia, S. R., Krishnaswamy, A., Whisenant, B. K., Potluri, S. P., Iyer, V., Aragon, J. R., Gideon, P. A., Strote, J. A., Leonardi, R. A., Agarwal, H., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.067312 · Cited by 63
Self-citationWazni, O. M., Boersma, L. V. A., Healey, J. S., MANSOUR, M. C., Tondo, C., Phillips, K. P., Doshi, R. N., Jaber, W. A., Hynes, E., Allocco, D. J., et al. (2022) · American Heart Journal · doi:10.1016/j.ahj.2022.05.003 · Cited by 42
Self-citationOkumura, Y., Nagashima, K., Arai, M., Watanabe, R., Yokoyama, K., Matsumoto, N., Otsuka, T., Suzuki, S. S., Hirata, A., Murakami, M., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0602 · Cited by 38
Community pharmacy-based study of adherence to non-vitamin K antagonist oral anticoagulants
Capiau, A., Mehuys, E., Tongelen, I. V., Christiaens, T. C., Sutter, A. D., Steurbaut, S., Moudallel, S., Rydant, S., Vrijens, B., Backer, T. L. M. D., et al. (2020) · Heart · doi:10.1136/heartjnl-2020-316781 · Cited by 26
Long-term oral anticoagulant after catheter ablation for atrial fibrillation
Chew, D. S., & Piccini, J. P. (2021) · EP Europace · doi:10.1093/europace/euaa365 · Cited by 24
Cited by
Kumbhani, D. J., Armbruster, A. L., Cheng, R. K., Chrispin, J., Fischer, U., Holbrook, A. M., Joglar, J., & Sevestre, M.-A. (2026) · JACC · doi:10.1016/j.jacc.2026.05.033 · Cited by 2
Metadata
- Authors
- Wazni, O. M., Saliba, W. I., Nair, D. G., Marijon, E., Schmidt, B., Hounshell, T., Ebelt, H., Skurk, C., Oza, S., Patel, C., Kanagasundram, A., Sadhu, A., Sundaram, S., Osorio, J., Mark, G., Gupta, M., DeLurgio, D. B., Olson, J., Nielsen-Kudsk, J. E., Boersma, L. V. A., Healey, J. S., Phillips, K. P., Asch, F. M., Wolski, K., Roy, K., Christen, T., Sutton, B. S., Stein, K. M., & Reddy, V. Y.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2025-04-03
- Volume
- 392
- Issue
- 13
- Pages
- 1277-1287
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4404442179
- Cited by
- 236
- References
- 25
- FWCI
- 63.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.