The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Effect of Bar-Code Technology on the Safety of Medication Administration
Open accessAbstract
BACKGROUND: Serious medication errors are common in hospitals and often occur during order transcription or administration of medication. To help prevent such errors, technology has been developed to verify medications by incorporating bar-code verification technology within an electronic medication-administration system (bar-code eMAR). METHODS: We conducted a before-and-after, quasi-experimental study in an academic medical center that was implementing the bar-code eMAR. We assessed rates of errors in order transcription and medication administration on units before and after implementation of the bar-code eMAR. Errors that involved early or late administration of medications were classified as timing errors and all others as nontiming errors. Two clinicians reviewed the errors to determine their potential to harm patients and classified those that could be harmful as potential adverse drug events. RESULTS: We observed 14,041 medication administrations and reviewed 3082 order transcriptions. Observers noted 776 nontiming errors in medication administration on units that did not use the bar-code eMAR (an 11.5% error rate) versus 495 such errors on units that did use it (a 6.8% error rate)--a 41.4% relative reduction in errors (P<0.001). The rate of potential adverse drug events (other than those associated with timing errors) fell from 3.1% without the use of the bar-code eMAR to 1.6% with its use, representing a 50.8% relative reduction (P<0.001). The rate of timing errors in medication administration fell by 27.3% (P<0.001), but the rate of potential adverse drug events associated with timing errors did not change significantly. Transcription errors occurred at a rate of 6.1% on units that did not use the bar-code eMAR but were completely eliminated on units that did use it. CONCLUSIONS: Use of the bar-code eMAR substantially reduced the rate of errors in order transcription and in medication administration as well as potential adverse drug events, although it did not eliminate such errors. Our data show that the bar-code eMAR is an important intervention to improve medication safety. (ClinicalTrials.gov number, NCT00243373.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127
Self-citationBates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Self-citationImproving Safety with Information Technology
Bates, D. W., & Gawande, A. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020847 · Cited by 1,544
Self-citationRelationship between medication errors and adverse drug events
Bates, D. W., Boyle, D. L., Vliet, M. B. V., Schneider, J., & Leape, L. (1995) · Journal of General Internal Medicine · doi:10.1007/bf02600255 · Cited by 981
Self-citationKoppel, R., Wetterneck, T., Telles, J. L., & Karsh, B.-T. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2616 · Cited by 685
Cited by
An overview of clinical decision support systems: Benefits, risks, and strategies for success
Sutton, R. T., Pincock, D., Baumgart, D. C., Sadowski, D. C., Fedorak, R. N., & Kroeker, K. I. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0221-y · Cited by 3,019
ASHP Guidelines on Preventing Medication Errors in Hospitals
Billstein-Leber, M., Carrillo, C. J. D., Cassano, A. T., Moline, K., & Robertson, J. J. (2018) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp170811 · Cited by 398
Health information technology: fallacies and sober realities
Karsh, B.-T., Weinger, M. B., Abbott, P. A., & Wears, R. L. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2010.005637 · Cited by 365
Starmer, A. J., Sectish, T. C., Simon, D. W., Keohane, C., McSweeney, M. E., Chung, E. Y., Yoon, C. S., Lipsitz, S. R., Wassner, A. J., Harper, M. B., et al. (2013) · JAMA · doi:10.1001/jama.2013.281961 · Cited by 337
Self-citationMedication Adherence Apps: Review and Content Analysis
Ahmed, I., Ahmad, N. S., Ali, S., Ali, S., George, A., Saleem Danish, H., Uppal, E., Soo, J., Mobasheri, M. H., King, D., et al. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.6432 · Cited by 221
Metadata
- Authors
- Poon, E. G., Keohane, C. A., Yoon, C. S., Ditmore, M., Bane, A., Levtzion-Korach, O., Moniz, T., Rothschild, J. M., Kachalia, A. B., Hayes, J., Churchill, W. W., Lipsitz, S., Whittemore, A. D., Bates, D. W., & Gandhi, T. K.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-05-06
- Volume
- 362
- Issue
- 18
- Pages
- 1698-1707
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2140207879
- Cited by
- 588
- References
- 5
- FWCI
- 72.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Bar-Code Technology on the Safety of Medication Administration. https://app.cochat.ai/papers/10.1056/nejmsa0907115
- The paper
- Poon, E. G., Keohane, C. A., Yoon, C. S., Ditmore, M., Bane, A., Levtzion-Korach, O., Moniz, T., Rothschild, J. M., Kachalia, A. B., Hayes, J., Churchill, W. W., Lipsitz, S., Whittemore, A. D., Bates, D. W., & Gandhi, T. K. (2010). Effect of Bar-Code Technology on the Safety of Medication Administration. New England Journal of Medicine. https://doi.org/10.1056/nejmsa0907115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.