The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Improved fiber-optic interferometer for atomic force microscopy
Abstract
A high-sensitivity fiber-optic displacement sensor for atomic force microscopy is described. The sensor is based on the optical interference occurring in the micron-sized cavity formed between the cleaved end of a single-mode optical fiber and the microscope cantilever. As a result of using a diode laser light source and all-fiber construction, the sensor is compact, mechanically robust, and exhibits good low-frequency noise behavior. Peak-to-peak noise in a dc to 1 kHz bandwidth is less than 0.1 Å. Images are presented demonstrating atomic resolution of graphite and magnetic force imaging of bits written on a magnetic disk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Review of Progress in Quantitative Nondestructive Evaluation: Volume 15A
(1996) · Springer eBooks · doi:10.1007/978-1-4613-0383-1 · Cited by 1,963
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Magnetic imaging by ‘‘force microscopy’’ with 1000 Å resolution
Martin, Y., & Wickramasinghe, H. K. (1987) · Applied Physics Letters · doi:10.1063/1.97800 · Cited by 1,151
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Atomic Resolution with Atomic Force Microscope
Binnig, G., Gerber, C., Stoll, E., Albrecht, T. R., & Quate, C. F. (1987) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/3/12/006 · Cited by 559
Atomic force microscopy of liquid-covered surfaces: Atomic resolution images
Marti, O., Drake, B., & Hansma, P. K. (1987) · Applied Physics Letters · doi:10.1063/1.98374 · Cited by 303
Cited by
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Self-citationScratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Measurement of the Casimir Force between Parallel Metallic Surfaces
Bressi, G., Carugno, G., Onofrio, R., & Ruoso, G. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.041804 · Cited by 891
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Metadata
- Authors
- Rugar, D., Mamin, H. J., & Guethner, P.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1989-12-18
- Volume
- 55
- Issue
- 25
- Pages
- 2588-2590
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2011109350
- Cited by
- 629
- References
- 9
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.