The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation
Abstract
Coherent properties of the x-ray beam delivered at the ESRF allow the observation of very weak perturbations of the wave front, resulting in the phase contrast. A straightforward experimental setup for phase contrast imaging is proposed and used to record holographic images from organic samples of 10–100 μm at energy 10–50 keV with the contrast up to 50%–100%. The theory of phase contrast imaging is considered and some theoretical estimations are made to reveal the performance of the proposed technique in terms of resolution, sensitivity, geometrical requirements, and energy range applicability. It is found that for carbon-based fibers a detectable size with 2% contrast is 0.1 μm for 10 keV and −1 μm for 100 keV. It is demonstrated that the fine interference structure of the image is very sensitive to the shape, density variation, and internal structure of the sample. Some prospects for the practical use and future development of the new coherent techniques such as phase contrast microscopy, microtomography, holography, and interferometry at high energies are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonse, U., & Hart, M. (1965) · Applied Physics Letters · doi:10.1063/1.1754212 · Cited by 1,057
Phase-contrast imaging of weakly absorbing materials using hard X-rays
Davis, T. J., Gao, D., Gureyev, T. E., Stevenson, A. W., & Wilkins, S. W. (1995) · Nature · doi:10.1038/373595a0 · Cited by 1,010
High-Resolution Imaging by Fourier Transform X-ray Holography
McNulty, I., Kirz, J., Jacobsen, C. J., Anderson, E. H., Howells, M. R., & Kern, D. P. (1992) · Science · doi:10.1126/science.256.5059.1009 · Cited by 316
X-ray holographic microscopy using photoresists
Jacobsen, C. J., Howells, M., Kirz, J., & Rothman, S. S. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.001847 · Cited by 115
Cited by
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
X-ray phase imaging with a grating interferometer
Weitkamp, T., Diaz, A., David, C., Pfeiffer, F., Stampanoni, M., Cloetens, P., & Ziegler, E. (2005) · Optics Express · doi:10.1364/opex.13.006296 · Cited by 1,211
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999) · Applied Physics Letters · doi:10.1063/1.125225 · Cited by 1,078
X-ray phase-contrast imaging: from pre-clinical applications towards clinics
Bravin, A., Coan, P., & Suortti, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/1/r1 · Cited by 846
Noninterferometric Phase Imaging with Partially Coherent Light
Paganin, D., & Nugent, K. A. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.2586 · Cited by 770
X-ray computed tomography of polymer composites
Garcea, S. C., Wang, Y., & Withers, P. J. (2018) · Composites Science and Technology · doi:10.1016/j.compscitech.2017.10.023 · Cited by 719
Quantitative Phase Imaging Using Hard X Rays
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D., & Barnea, Z. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2961 · Cited by 675
Linac Coherent Light Source: The first five years
Bostedt, C., Boutet, S., Fritz, D. M., Huang, Z., Lee, H. J., Lemke, H. T., Robert, A., Schlotter, W. F., Turner, J. J., & Williams, G. J. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.015007 · Cited by 618
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
Coherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Contrast and resolution in imaging with a microfocus x-ray source
Pogany, A., Gao, D., & Wilkins, S. W. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148194 · Cited by 476
Tafforeau, P., Boistel, R., Boller, E., Bravin, A., Brunet, M., Chaimanee, Y., Cloetens, P., Feist, M., Hoszowska, J., Jaeger, J.-J., et al. (2006) · Applied Physics A · doi:10.1007/s00339-006-3507-2 · Cited by 456
Dynamical Theory of X-Ray Diffraction
Authier, A. (2003) · doi:10.1093/acprof:oso/9780198528920.001.0001 · Cited by 331
X-ray computed microtomography (μCT) using synchrotron radiation (SR)
Bonse, U., & Busch, F. (1996) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(96)00011-9 · Cited by 304
PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction
Chen, R.-C., Dreossi, D., Mancini, L., Menk, R., Rigon, L., Xiao, T.-Q., & Longo, R. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512029731 · Cited by 279
ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs
Weitkamp, T., Haas, D., Wegrzynek, D., & Rack, A. (2011) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511002895 · Cited by 278
BETZ, O., WEGST, U., WEIDE, D., HEETHOFF, M., HELFEN, L., LEE, W., & CLOETENS, P. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01785.x · Cited by 277
Development of phase-contrast X-ray imaging techniques and potential medical applications
Zhou, S.-A., & Brahme, A. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.05.006 · Cited by 268
Phase retrieval in X-ray phase-contrast imaging suitable for tomography
Burvall, A., Lundström, U., Takman, P. A. C., Larsson, D. H., & Hertz, H. M. (2011) · Optics Express · doi:10.1364/oe.19.010359 · Cited by 263
Fast 3D reconstruction method for differential phase contrast X-ray CT
McCann, M. T., Nilchian, M., Stampanoni, M., & Unser, M. (2016) · Optics Express · doi:10.1364/oe.24.014564 · Cited by 28
Metadata
- Authors
- Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1995-12-01
- Volume
- 66
- Issue
- 12
- Pages
- 5486-5492
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2053331261
- Cited by
- 1,493
- References
- 4
- FWCI
- 18.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.