A new method for measuring thermal conductivity of thin films
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new, relatively inexpensive, easy-to-use instrument has been developed for measuring the thermal conductivity of thin films based on a differential photoacoustic method. Measurements made on silicon dioxide and silicon nitride are consistent with those reported previously for a different technique. In addition, the room temperature thermal conductivity of conventional polymer thin films and plasma deposited thin films has been determined relative to thermally grown silicon dioxide. Knowledge of the thermal conductivity of thin films, which is critical for many applications, can now be obtained for any thin film which can be deposited on a high thermal conductivity substrate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928
Thermal conductivity of thin films: Measurements and understanding
Cahill, D. G., Fischer, H. E., Klitsner, T., Swartz, E. T., & Pohl, R. O. (1989) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576265 · Cited by 321
Solid Layer Thermal-Conductivity Measurement Techniques
Goodson, K. E., & Flik, M. I. (1994) · Applied Mechanics Reviews · doi:10.1115/1.3111073 · Cited by 75
Cited by
Rapid thermal conductivity measurement with a hot disk sensor
He, Y. (2005) · Thermochimica Acta · doi:10.1016/j.tca.2005.06.026 · Cited by 459
Palacios, A., Cong, L., Navarro, M. E., Ding, Y., & Barreneche, C. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.03.020 · Cited by 237
Thermal properties of metal-halide perovskites
Haeger, T., Heiderhoff, R., & Riedl, T. (2020) · Journal of Materials Chemistry C · doi:10.1039/d0tc03754k · Cited by 177
Ahadi, M., Andisheh-Tadbir, M., Tam, M., & Bahrami, M. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.01.037 · Cited by 76
“Differential photoacoustic For measurement of thermal conductivity of thin films [23] Not available Pulsed photothermal displacement For measurement of thermal diffusivity of solids [24] Not available Thermal-wave For measurement of thermal diffusivity of high temperature superconductors [25] Temperature range from 10…”
Li, Y., Shi, C., Liu, J., Liu, E., Shao, J., Chen, Z., Dorantes-Gonzalez, D. J., & Hu, X. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/015006 · Cited by 41
“Transient plane source (TPS) method [4], hot wire [5], laser flash [6], 3ω (three omega) method [7–9], differential photo-acoustic method [10], photothermal deflection method or probe-beam deflection method [11, 12], thermal-wave technique [13], thermoreflectance method [14] and differential scanning calorimetry [15]…”
Method
Metadata
- Authors
- Govorkov, S., Ruderman, W., Horn, M. W., Goodman, R. B., & Rothschild, M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1997-10-01
- Volume
- 68
- Issue
- 10
- Pages
- 3828-3834
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1987886000
- Cited by
- 55
- References
- 3
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.