Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A novel diamagnetic lateral force calibrator (D-LFC) has been developed to directly calibrate atomic force microscope (AFM) cantilever-tip or -bead assemblies. This enables an AFM to accurately measure the lateral forces encountered in friction or biomechanical-testing experiments at a small length scale. In the process of development, deformation characteristics of the AFM cantilever assemblies under frictional loading have been analyzed and four essential response variables, i.e., force constants, of the assembly have been identified. Calibration of the lateral force constant and the “crosstalk” lateral force constant, among the four, provides the capability of measuring absolute AFM lateral forces. The D-LFC is composed of four NdFeB magnets and a diamagnetic pyrolytic graphite sheet, which can calibrate the two constants with an accuracy on the order of 0.1%. Preparation of the D-LFC and the data processing required to get the force constants is significantly simpler than any other calibration methods. The most up-to-date calibration technique, known as the “wedge method,” calibrates mainly one of the two constants and, if the crosstalk effect is properly analyzed, is primarily applicable to a sharp tip. In contrast, the D-LFC can calibrate both constants simultaneously for AFM tips or beads with any radius of curvature. These capabilities can extend the applicability of AFM lateral force measurement to studies of anisotropic multiscale friction processes and biomechanical behavior of cells and molecules under combined loading. Details of the D-LFC method as well as a comparison with the wedge method are provided in this article.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Calibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
An improved wedge calibration method for lateral force in atomic force microscopy
Varenberg, M., Etsion, I., & Halperin, G. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584082 · Cited by 427
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Variation of the Interfacial Shear Strength and Adhesion of a Nanometer-Sized Contact
Carpick, R. W., Agraït, N., Ogletree, D. F., & Salmeron, M. (1996) · Langmuir · doi:10.1021/la9509007 · Cited by 301
Diamagnetic levitation: Flying frogs and floating magnets (invited)
Simon, M. D., & Geim, A. K. (2000) · Journal of Applied Physics · doi:10.1063/1.372654 · Cited by 281
A Technique for Measuring the Force between a Colloidal Particle in Water and a Bubble
Butt, H.-J. (1994) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1994.1277 · Cited by 260
The Colloidal Probe Technique and its Application to Adhesion Force Measurements
Kappl, M., & Butt, H.-J. (2002) · Particle & Particle Systems Characterization · doi:10.1002/1521-4117(200207)19:3<129::aid-ppsc129>3.0.co;2-g · Cited by 256
Cited by
Frictional Characteristics of Atomically Thin Sheets
Lee, C., Li, Q., Kalb, W., Liu, X.-Z., Berger, H., Carpick, R. W., & Hone, J. (2010) · Science · doi:10.1126/science.1184167 · Cited by 1,811
Self-citationRobust microscale superlubricity in graphite/hexagonal boron nitride layered heterojunctions
Song, Y., Mandelli, D., Hod, O., Urbakh, M., Ma, M., & Zheng, Q. (2018) · Nature Materials · doi:10.1038/s41563-018-0144-z · Cited by 494
Carbon nanotube bundles with tensile strength over 80 GPa
Bai, Y., Zhang, R., Ye, X., Zhu, Z., Xie, H., Shen, B., Cai, D., Liu, B., Zhang, C., Jia, Z., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0141-z · Cited by 449
Measurement of the cleavage energy of graphite
Wang, W., Dai, S., Li, X., Yang, J., Srolovitz, D. J., & Zheng, Q. (2015) · Nature Communications · doi:10.1038/ncomms8853 · Cited by 368
Robust microscale superlubricity under high contact pressure enabled by graphene-coated microsphere
Liu, S.-W., Wang, H.-P., Xu, Q., Ma, T.-B., Yu, G., Zhang, C., Geng, D., Yu, Z., Zhang, S., Wang, W., et al. (2017) · Nature Communications · doi:10.1038/ncomms14029 · Cited by 362
Metadata
- Authors
- Li, Q., Kim, K.-S., & Rydberg, A.
- Affiliations
- Brown University (US)
- ORCID
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-06-01
- Volume
- 77
- Issue
- 6
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2029314957
- Cited by
- 208
- References
- 18
- Citations by year
- 2026: 10 · 2025: 11 · 2024: 15 · 2023: 12 · 2022: 10 · 2021: 10 · 2020: 20 · 2019: 10 · 2018: 17 · 2017: 10 · 2016: 9 · 2015: 9 · 2014: 4 · 2013: 4 · 2012: 13
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 13 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 13 d)
- Locations
- Review of Scientific Instruments (publishedVersion, cc-by)
- Funders
- Rice University
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
- Keywords
- atomic force microscopy, diamagnetic levitation, wedge method, friction measurement, Nd-Fe-B permanent magnets, pyrolytic graphite
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system. https://app.cochat.ai/papers/10.1063/1.2209953
- The paper
- Li, Q., Kim, K.-S., & Rydberg, A. (2006). Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system. Review of Scientific Instruments. https://doi.org/10.1063/1.2209953
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.