The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Effects of elastic and inelastic interactions on phase contrast images in tapping-mode scanning force microscopy
Open accessAbstract
The dependence of phase contrast in tapping-mode scanning force microscopy on elastic and inelastic interactions is studied. The cantilever–tip ensemble is simulated as a driven, damped harmonic oscillator. It is found that for tip–sample elastic interactions, phase contrast is independent of the sample’s elastic properties. However, phase contrast associated with elastic modulus variations are observed if viscous damping or adhesion energy hysteresis is considered during tip–sample contact. The phase shift versus tip–sample equilibrium separation was measured for a compliant material (polypropylene) and for a stiff sample (mica). The agreement obtained between theory and experiment supports the conclusions derived from the model. These results emphasize the relevance of energy dissipating processes at the nanometer scale to explain phase contrast imaging in tapping-mode force microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Atomic Resolution of the Silicon (111)-(7×7) Surface by Atomic Force Microscopy
Giessibl, F. J. (1995) · Science · doi:10.1126/science.267.5194.68 · Cited by 1,189
Phase imaging and stiffness in tapping-mode atomic force microscopy
Magonov, S. N., Elings, V., & Whangbo, M.-H. (1997) · Surface Science · doi:10.1016/s0039-6028(96)01591-9 · Cited by 1,020
Fractured polymer/silica fiber surface studied by tapping mode atomic force microscopy
Zhong, Q., Inniss, D., Kjoller, K., & Elings, V. B. (1993) · Surface Science · doi:10.1016/0039-6028(93)90582-5 · Cited by 924
Fundamental mechanisms of interfacial friction. 1. Relation between adhesion and friction
Yoshizawa, H., Chen, Y. L., & Israelachvili, J. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100118a033 · Cited by 603
Scanning Force Microscopy in Biology
Bustamante, C., & Keller, D. (1995) · Physics Today · doi:10.1063/1.881478 · Cited by 271
Burnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
Cantilever dynamics in quasinoncontact force microscopy: Spectroscopic aspects
Anczykowski, B., Krüger, D., & Fuchs, H. (1996) · Physical review. B, Condensed matter · doi:10.1103/physrevb.53.15485 · Cited by 256
Interfacial interaction between low-energy surfaces
Chaudhury, M. K. (1996) · Materials Science and Engineering: R: Reports · doi:10.1016/0927-796x(95)00185-9 · Cited by 241
Driven nonlinear atomic force microscopy cantilevers: From noncontact to tapping modes of operation
Sarid, D., Ruskell, T. G., Workman, R. K., et al. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.589163 · Cited by 91
Numerical simulations of a scanning force microscope with a large-amplitude vibrating cantilever
Chen, J., Workman, R. K., Sarid, D., & Höper, R. (1994) · Nanotechnology · doi:10.1088/0957-4484/5/4/003 · Cited by 75
Cited by
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Self-citationCommensurate–incommensurate transition in graphene on hexagonal boron nitride
Woods, C. R., Britnell, L., Eckmann, A., Ma, R. S., Lu, J. C., Guo, H. M., Lin, X., Yu, G. L., Cao, Y., Gorbachev, R. V., et al. (2014) · Nature Physics · doi:10.1038/nphys2954 · Cited by 912
Energy dissipation in tapping-mode atomic force microscopy
Cleveland, J. P., Anczykowski, B., Schmid, A. E., & Elings, V. B. (1998) · Applied Physics Letters · doi:10.1063/1.121434 · Cited by 881
Attractive and repulsive tip-sample interaction regimes in tapping-mode atomic force microscopy
García, R., & San Paulo, A. (1999) · Physical Review B · doi:10.1103/physrevb.60.4961 · Cited by 570
Self-citationProduction and processing of graphene and related materials
Backes, C., Abdelkader, A. M., Alonso, C., Andrieux-Ledier, A., Arenal, R., Azpeitia, J., Balakrishnan, N., Banszerus, L., Barjon, J., Bartali, R., et al. (2020) · 2D Materials · doi:10.1088/2053-1583/ab1e0a · Cited by 501
Metadata
- Authors
- Tamayo, J., & Garcı́a, R.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1997-10-20
- Volume
- 71
- Issue
- 16
- Pages
- 2394-2396
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2023690704
- Cited by
- 292
- References
- 11
- FWCI
- 10.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.