The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Energy dissipation in tapping-mode atomic force microscopy
Abstract
A method is presented to measure the energy dissipated by the tip–sample interaction in tapping-mode atomic force microscopy (AFM). The results show that if the amplitude of the cantilever is held constant, the sine of the phase angle of the driven vibration is then proportional to changes in the tip–sample energy dissipation. This means that images of the cantilever phase in tapping-mode AFM are closely related to maps of dissipation. The maximum dissipation observed for a 4 N/m cantilever with an initial amplitude of 25 nm tapping on a hard substrate at 74 kHz is about 0.3 pW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Phase imaging and stiffness in tapping-mode atomic force microscopy
Magonov, S. N., Elings, V., & Whangbo, M.-H. (1997) · Surface Science · doi:10.1016/s0039-6028(96)01591-9 · Cited by 1,020
Self-citationFractured polymer/silica fiber surface studied by tapping mode atomic force microscopy
Zhong, Q., Inniss, D., Kjoller, K., & Elings, V. B. (1993) · Surface Science · doi:10.1016/0039-6028(93)90582-5 · Cited by 924
Self-citationShort cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Self-citationTamayo, J., & Garcı́a, R. (1997) · Applied Physics Letters · doi:10.1063/1.120039 · Cited by 292
Burnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
Anczykowski, B., Krüger, D., Babcock, K. L., et al. (1996) · Ultramicroscopy · doi:10.1016/s0304-3991(97)00002-8 · Cited by 157
Self-citationDriven nonlinear atomic force microscopy cantilevers: From noncontact to tapping modes of operation
Sarid, D., Ruskell, T. G., Workman, R. K., et al. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.589163 · Cited by 91
Physical properties of dynamic force microscopies in contact and noncontact operation
Krüger, D., Anczykowski, B., & Fuchs, H. (1997) · Annalen der Physik · doi:10.1002/andp.19975090502 · Cited by 52
Self-citation
Cited by
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Effective Passivation of Exfoliated Black Phosphorus Transistors against Ambient Degradation
Wood, J. D., Wells, S. A., Jariwala, D., Chen, K.-S., Cho, E., Sangwan, V. K., Liu, X., Lauhon, L. J., Marks, T. J., & Hersam, M. C. (2014) · Nano Letters · doi:10.1021/nl5032293 · Cited by 1,491
Hybrid Zinc Oxide Conjugated Polymer Bulk Heterojunction Solar Cells
Beek, W. J. E., Wienk, M. M., Kemerink, M., Yang, X., & Janssen, R. A. J. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp050745x · Cited by 910
Structural heterogeneities and mechanical behavior of amorphous alloys
Qiao, J. C., Wang, Q., Pelletier, J. M., Kato, H., Casalini, R., Crespo, D., Pineda, E., Yao, Y., & Yang, Y. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.04.005 · Cited by 659
α-Synuclein Membrane Interactions and Lipid Specificity
Jo, E., McLaurin, J., Yip, C. M., St. George-Hyslop, P., & Fraser, P. E. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m004345200 · Cited by 604
Metadata
- Authors
- Cleveland, J. P., Anczykowski, B., Schmid, A. E., & Elings, V. B.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1998-05-18
- Volume
- 72
- Issue
- 20
- Pages
- 2613-2615
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1987432469
- Cited by
- 881
- References
- 9
- FWCI
- 23.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.