The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Micromechanical cantilever as an ultrasensitive pH microsensor
Abstract
We report on a pH sensor with ultrahigh sensitivity based on a microcantilever structure with a lithographically-defined crosslinked copolymeric hydrogel. Silicon-on-insulator wafers were used to fabricate cantilevers on which a polymer consisting of poly(methacrylic acid) (PMAA) with poly(ethylene glycol) dimethacrylate was patterned using free-radical UV polymerization. As the pH around the cantilever was increased above the pKa of PMAA, the polymer network expanded and resulted in a reversible change in surface stress causing the microcantilever to bend. Excellent mechanical amplification of polymer swelling as a function of pH change within the dynamic range was obtained, with a maximum deflection sensitivity of 1 nm/5×10−5 ΔpH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Hydrogels in Medicine and Pharmacy
Peppas, N. A. (1987) · Cited by 1,648
Self-citationLight-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
Smart single-chip gas sensor microsystem
Hagleitner, C., Hierlemann, A., Lange, D., Kummer, A., Kerness, N., Brand, O., & Baltes, H. (2001) · Nature · doi:10.1038/35104535 · Cited by 619
Surface micropatterning to regulate cell functions
Ito, Y. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00162-3 · Cited by 500
Origin of nanomechanical cantilever motion generated from biomolecular interactions
Wu, G., Ji, H., Hansen, K., Thundat, T., Datar, R., Cote, R., Hagan, M. F., Chakraborty, A. K., & Majumdar, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.4.1560 · Cited by 415
Brannon-Peppas, L., & Peppas, N. A. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90021-h · Cited by 190
Self-citationPhysiologically Responsive Hydrogels
Peppas, N. A. (1991) · Journal of Bioactive and Compatible Polymers · doi:10.1177/088391159100600303 · Cited by 160
Self-citation
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Self-citationMicro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Stimuli-responsive hydrogel thin films
Tokarev, I., & Minko, S. (2009) · Soft Matter · doi:10.1039/b813827c · Cited by 579
Biomimetic Hydrogel‐Based Actuating Systems
Ionov, L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203692 · Cited by 469
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
Self-citation
Metadata
- Authors
- Bashir, R., Hilt, J. Z., Elibol, O., Gupta, A., & Peppas, N. A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2002-10-14
- Volume
- 81
- Issue
- 16
- Pages
- 3091-3093
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2114659148
- Cited by
- 300
- References
- 16
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micromechanical cantilever as an ultrasensitive pH microsensor. https://app.cochat.ai/papers/10.1063/1.1514825
- The paper
- Bashir, R., Hilt, J. Z., Elibol, O., Gupta, A., & Peppas, N. A. (2002). Micromechanical cantilever as an ultrasensitive pH microsensor. Applied Physics Letters. https://doi.org/10.1063/1.1514825
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.